The double chamfer is used for chamfering the holes on the waist of railway rail.
The structure of the bilateral chamfering device: It has a door frame, the left and right holder through a set of four bar linkage hinge, and equipped with upper locking lever handle, install left axle shaft sleeve of the bottom of the left bracket, left axis right side is equipped with disc blade, left left end shaft with a ratchet wrench, right shaft are installed in the shaft sleeve from the lower pole of the right holder, the right shaft suits a compression spring, right left end shaft is equipped with the disc blade, The right end of the right axle is fitted with a ratchet wrench.
The double - sided chamfering device has the advantages of simple structure, convenient operation and high working efficiency.
The blade is disk - shaped, the blade on the whole circumference is sharp and wear - resistant, and the service life is long.
The portable laser string is a special auxiliary construction tool for short-wave irregularity during the construction of existing lines and high-speed railway turnout sections (or straight sections); it mainly consists of three parts: laser emitting device, target positioning target, and mobile positioning target.
The tip rail reduction value measuring ruler is used to measure the reduction value of the tip rail relative to the base rail, the reduction value of the heart rail relative to the wing rail, and the vertical wear value of any part of the wear section of the frog wing rail. It has the advantages of high measurement accuracy, easy to master by on-site workers, high reliability, small size and light weight.
443 Tools Instruments Suppliers
Short on time? Let Tools Instruments sellers contact you.
Rail Saw Railroad Cutter Track Disassembly Equipment Rail Dismantling Tool
Lithium Battery Rail Cutting Machine is professional for rail cutting work.
Benefits
1. Passed the strict verification of protection grade, and supports the work in rainy and snowy weather;
2. Professional lithium battery which can support long time operation
3. Can be worked under under extreme conditions, such as high cold and high altitude;
4. Lithium battery passed the safety inspection of the national authority
5. Adjustable clamp , Suitable for cutting various type of rail.
6. Light weight , portable to carry and operate.
Magnet pointer rail thermometer is used to measure the temperature of rail. rail thermometer is not only dedicated to measure the temperature of the railway rails, but also can measure the air temperature and the surface temperature of other objects.
Power Recording Analyzer is designed for power signal record. The power generator test items are integrated at the tester. With those test items users can make motor Power generator No load test, Short circuit test, Motor excitation step response test, motor excitatory de excitation test, motor load rejection test and grid synchronous connection test and also on
Technique index
There are 12channels voltage current sample. The analog range include 10V10V, 200V 200V, 400V 400V and 20mA 20mA. Users can switch the input range from software. Also there is one channel 100mV 100mV which allow the input signal less than 10V.
The voltage and current input range assured errors are as follow
400V 400V assured error less than 0.5V
200V 200V assured error less than 0.2V
10V 10V assured error less than 0.01V
20mA 20mA assured error less than 0.02m
100mV 100mV assured error less than 0.2mV
There are 12 channel wet contacts binary signal input. The valid and allowed input voltage is DC12-200V.
There are 3 channel relay contacts output. The maximum capacity for the contacts is AC220V 1A.
There are 2 USB port used for data export and mouse keyboard input
The LCD is 12.1 inches touch pad input mode. Make the human interface more simple.
The saved space in the tester is 32G for standard configuration
Input resistances for different channels are as follow
Transformer oil acid tester is a fully automatic measuring instrument which adopts the extraction method to accurately detect the insulating oil acid value. This instrument can improve the working efficiency and test accuracy, and at the same time ensure the safety of the body by reducing the operator's contact with the samples and reagents.
The acid value is the trace value of potassium sulfate that neutralizes the petroleum acid in 1g of oil, which contains a certain amount of inorganic acid and inorganic acid. The acid value includes organic and inorganic acids contained in the oil. In most cases, oil does not contain mineral acids. Therefore, the oleic acid value actually represents the content of organic acids in the oil. The organic acid contained in the new oil is mainly cyclonic acid. In the oil and in the process of use, the acid value of the oil produced by oxidation is an indicator to measure the degree of refining of the new oil. Whether the oil is running is an important indicator of the continued use of oil quality equipment.
Mould Oscillation and Deflection Detection Instrument
Overview
The mold is a device that shapes the cast product in continuous steel casting, and it is also the core equipment and key technology of continuous casting machine. The main function of the mould oscillation deflection detection instrument is to detect the the mould oscillation table s oscillation frequency, amplitude, deflection rate, phase, oscillation trajectory curve, etc. Through the detection and adjustment of the detection instrument, the mold moves along the outer arc of the continuous casting machine according to the given amplitude, frequency and waveform deflection characteristics.
The actual oscillation parameters of the mold oscillation table during the operation and production process and the process parameters of the cast products cannot be effectively known without the data detection of the mold deflection detection instrument, so that the operator cannot adjust the mould s production process parameters in real time according to the real-time situation of the on-site production.
The continuous casting mold deflection detection instrument independently developed by our company is suitable for various molds such as slab, square billet, round billet and shaped billet. The system obtains the process parameters such as actual oscillation holographic parameters and negative slip amount of the oscillation table by effectively detecting the movement of the mold. The technicians can formulate the control strategy of the mould according to these actual parameters, and improve the output and quality of the product within a safe and reliable range.
The structure of the instrument
Continuous casting mold oscillation and deflection detection instrument is mainly composed of sensor system, sensor signal conditioning circuit, power supply circuit, synchronous data acquisition module, communication cable, and software data analysis system.
There are three axial acceleration sensors installed in the mold oscillation and deflection detection instrument, one of which is to detect the vertical oscillation signal (Y axis), and the other two are to detect the horizontal oscillation signal (X and Z axis). The signal obtained by the sensor is processed by the preprocessor and the preprocessing module. The oscillation signal and sensor status signal will be filtered and normalized, sent to the synchronous data collector for digitization and feature extraction, and the data is analyzed and processed by the master computer software to obtain various oscillation parameters and process parameters required by users.
We are the manufacturer of rail construction machinery & tools in china.like digital track gauge, wear gauge, rail clamp, torque wrench, rail drilling machine, cutting machine,rail grinding machine.
Insulation resistance tester with absorption ratio embedded real-time industrial microcomputer operating system, ultra-thin wire-shaped sheets header with the perfect combination of dot matrix liquid crystal display, the instrument is with a variety of voltage output level (250V,500V,1000V,2500V,5000V,10000V), high capacity, strong anti-interference, the pointer and digital synchronous display, AC-DC dual-use, simple operation, automatic calculation of various insulation index (absorption ratio, polarization index), all measured characteristics with the anti-power-down function .
Frequency conversion series resonance test device is designed and manufactured for alternating-current withstand voltage test of Possessing a wider application scope, it is the ideal withstand voltage equipment for prefecture-level, municipal-level and county-level high-voltage test departements as well as power installation and repair & testing engineering units.
Frequency Conversion Series Resonance Test Device
(I) Technical index
1. Rated voltage:
2. Quality factor under full load in test of fire power generator: Q10 (relating to load)
3. Quality factor under full load in cable test: Q 30 (relating to load)
4. Quality factor under full load in test of main transformer: Q 30 (relating to load)
5. GIS, the quality factor under full load in switch test and other tests: Q 50 (relating to load)
6. Input power supply: single phase of 380V
7. Frequency adjustment range: 20Hz 300Hz
8. Accuracy of system measurement: 1.5
9. The unit possesses protective functions, such as over voltage, over current and zero start.
(II) Description for main configuration and technical data of equipment:
1. One set of variable-frequency power supply:
Rated power: 10kVA;
Input voltage: single phrase of 220V or three phase of 380V 10% and 45 65Hz
Output voltage: 0 400V adjustable
Output voltage frequency: 30 300Hz
0.1Hz adjustable stepping
Instability degree of frequency 0.02%
Output current: 0 25A
2. High-voltage resonane reactor (4sets in all): 27kV/1A
The handheld SF6 gas leak detector is a stable and sensitive leak detector. We have fully considered the actual needs of the majority of users, and at the same time apply our rich technology and experience to this product, allowing users to enjoy an excellent price-performance ratio.
The high-tech central microprocessor unit is the core of the qualitative leak detector for sulfur hexafluoride gas. Its digital signal processing capabilities can better manage circuits and process detection signals. Due to the use of a large number of integrated circuits, the number of components in the circuit is reduced by 40%, which greatly improves reliability and efficiency. The microprocessor can monitor the probe and battery voltage at a rate of 4000 times per second. Even the smallest signal can be captured. It can work stably and reliably in any environment.
The SF6 gas qualitative leak detector has added some convenient functions. Seven-level sensitivity, the sensitivity is increased by 64 times. The three-color LED gradually indicates the degree of leakage in a large range, and is also used to display the sensitivity level and battery power. Touch the keyboard to perform all operations. The avant-garde slender shape design greatly facilitates the user's use and maintenance. It is very convenient to use the indicator light in the direct range.
Technical parameters:
Power supply 3V DC 2 alkaline batteries
Maximum sensitivity R12 R22 R134a approved (14g/year)
Limiting sensitivity about 20 hours
Probe life About 20 hours
Operating temperature
Battery life about 30 hours under normal use
Working way continuous unlimited
Response time instantaneous
Reset time 1 SEC
Warm-up time about 2 seconds
Weight 560g
Product description AC DC high voltage dividerFRC series AC DC high voltage divider also known as FRC Divider, it is a kind of resistance-capacitance equivalent potential screen voltage division type high voltage measurement device, is mainly used for the measurement of pulsed high voltage, lightning high voltage and power frequency high voltage. It is the first choice for the replacement of high voltage electrostatic voltmeter.
Dielectric strength tester forTransformer Oil BDV Tester Three Cups insulation oil is my company all the scientific and technical personnel according to national standard GB507-86 line and the DL - 474-4-92 the relevant provisions of the DL/T596-1996 play their own advantages after a lot of field test and long-term unremitting efforts carefully research and development of high accuracy fully digital industrial equipment.Dielectric strength tester for insulation oil as a simple modelling is beautiful and easy.Due to the use of automatic digital microcomputer control so high measurement accuracy strong anti-interference ability safe and reliable.
Technical parameters
Booster capacity 1.5kVA
Booster speed 2.0kV /s 2.5kv /s 3.0kV /s 3.5kV /s
error: 0.2 kV/s
The output voltage 0 80kV (optional)
Voltage accuracy (2% reading +2 words)
Power distortion rate 1
Electrode gap standard 2.5 mm
Number of test 6 times (1-6 times optional)
Let stand time 5 min (1-9min optional)
Dimensions 670mm 420mm 410mm
Weight 38kg
Product description
120KV 10ma DC Cable Test System is an important equipment for DC voltage withstand test and leakage current test of HV electrical equipments, cables, surge arresters in electriv industry and power supply departments. 120KV 10ma DC Cable Test System is developed based on the calibration made by National HV Meterage Station, it accords with the standard Generation Requirement of Portable HVDC Generator ZGF 24003 90
Oil trace moisture tester This instrument is able to work more reliably and conveniently by using the most advanced control circuit and 32 bit embedded microcontroller processor as the master control core and utilizing embedded mini operating system.