The accuracy of its performance parameters related to the safety of patients, must be through the corresponding detection equipment AED production of the performance parameters of the test and regular performance check.
Meditech D-Sense automated external defibrillator analyzer can simulate a variety of normal and abnormal ECG signals for defibrillator testing, test the ability of the defibrillator to analyze ECG signals, and display the defibrillator primary discharge energy and energy via the LED digital tube Discharge voltage values, the selection of ECG signals for different tests, and the display of voltage display or primary discharge energy are achieved by key operation. The overall operation of the instrument is simple and convenient.
Supplier: Anaesthesia machine, ventilator, ultrasound scanner, X-ray machine, defibrillator, patient monitor, ECG machine, electrosurgical unit hospital furniture, O.T lamp/table, dental unit, colposcope, operation microscope, infant incubator, infant radiant warmer, infant photo-therapy unit sterilizer (autoclave), laboratory equipment, PCR analyzer, syringe pump, infusion pump, blood pressure monitor, pulse oximeter
Supplier: Medical equipment, medical device, cardiology (resting ECG machine, holter ECG monitor, holter blood pressure monitor, stress testing system, defibrillator, aed, spirometer), patient monitoring (multi parameter patient monitor, vital sign monitor, handheld pulse oximeter, fingertip pulse oximeter, blood pressure monitor), home healthcare (fetal doppler, thermometer, infrared thermometer, glucometer, oxygen concentrator), disposable & consumable ( ECG recording paper, ctg recording paper, biochemistry analyzer recording paper, patient monitor recording paper, spirometer recording paper, ultrasound recording paper, ECG gel, ultrasound gel, disposable ECG electrode, disposable tnt electrode, disposable ESU electrode, disposable holter ECG electrode, NIBP cuff, spo2 probe, spo2 sensor, ECG cable for patient monitor, patient cable for ECG machine, limb electrode for ECG machine, chest electrode for ECG machine, syringe, surgical blade)
* Fully stainless steel structure * Hand wheel type of quick open door structure * Door safety lock system * Automatically controlled by computer * Digital display of working status, touch type key * Over temperature & over pressure auto protection * Steam water inner circulation system, no steam discharge and the environment for sterilizing will be clean and dry * Self inflating type seal * Safe protection of water lacking * The drying system is optional, which can be equipped according to the customer's request * Automatically shut iff with beep reminding after sterilization * With two stainless steel sterilizing baskets.
Supplier: Anaesthesia machine, patient monitor, X-ray machine, defibrillator, fetal monitor, ECG machine, medical pendant, O.T lamp, O.T table, sterilizer, autoclave, ventilator, electrosurgical unit, suction unit, ophthalmic equipment, colposcope, infant incubator, infant radiant warmer, infant photo-therapy unit, syringe pump, infusion pump, ultrasound scanner, laboratory equipment, PCR analyzer, dental unit, first-aid equipment, scales, ent equipment, oxygen concentrator, walking aids, hospital furniture
Specification: 1. Sample rate: 1000Hz, simultaneous 12 leads recording 2. Resolution:12bit 3. Power: 5.0V (DC) 4. Patient Insulation: 4000V AC 5. Defibrillation Protection: Built-in box 6. Digital resolution: 2ª¦V 7. Frequency response: 0.05-250 Hz 8. Common mode rejection: >90dB 9. Input impedance: >10Mª+ 10. Time constant: í¦3.2 s 11. Max electrode potential: í+300mV DC 12. Dynamic range: í+10mV 13. Isolate voltage: 4000V 14. Current leak:
Ar-325 anesthesia machine Main body High-strength engineering plastic rack, light, Beautiful and corrosion resistant Scope of application Adult, child Gas source O2: 0.27--0.55mpa n2o: 0.27--0.55mpa Flow meter O2 : 0.1--1.0l/min 1.1--10l/min N20: 0.1--1.0l/min 1.1--10l/min Air : 0.1--10l/min O2, n2o linkage and n2o stopper When using nitrous oxide, oxygen concentration>25%; When the oxygen pressure
Technical specifications Defibrillator -defibrillator type: manual, synchronized, asynchronized, -out put waveform: monophasic technology -energy accuracy:
15 inch Six Standard parameters: ECG, RESP, NIBP, SPO2, 2_TEMP, PR/HR 1.13 Type Arrhythmic Analysis, Multi-Lead ECG Waveforms Display in Phase, Real time S_T segment analysis, pacemaker detection Drug calculation and titratiotable; 2. Efficient resistance to interference of defibrillator and electrosurgical cautery; 3. SPO2 can testing for 0.1% Weak; 4. RA-LL impedance Respiration; 5. Trend Coexist Display; 6. OxyCRG Dynamic View Display; 7. Bed to Bed view Display; 8. Networking capacity and nurse calling system; 9. Options of printing, IBP, VGA and EtCO2; 10. UP to 4 hours working capacity of built-in rechargeable battery; 11.15" high resolution color TFT LCD display; 12. Large volume of tabular and graphic trends information storage and easy to recall; 13. Anti-ESU, anti- defibrillator; 14. Capture dynamic waveforms. Technical specification: ECG Lead Mode: 5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V) Lead selection: I, II, III, avR, avL, avF, V, Waveform: 2ch Lead mode: 3 Leads (R, L, F or RA, LA, LL) Lead selection: I, II, III, Waveform: 1ch Gain: ‘2.5mm/mV, ‘5.0mm/mV, ‘10mm/mV, ‘20mm/mV, auto HR and Alarm Range Adult: 15 ~ 300 bpm Neo/Ped: 15 ~ 350 bpm Accuracy: ± 1% or ± 1bpm, which great Resolution: 1 bpm Sensitivity: > 200 (uV P-P) Differential Input Impedance: > 5 MO CMRR Monitor: > 105 dB Operation: > 105 dB Diagnosis: > 85 dB Electrode offset potential: ±300mV Leakage Current: < 10uA Baseline Recovery: < 3 S after Defi. ECG Signal Range: ±8 m V (Vp-p) Bandwidth Surgery: 1 ~ 15 Hz Monitor: 0.5 ~ 35 Hz Diagnostic: 0.05 ~ 100 Hz Calibration Signal: 1 (mV p-p), Accuracy: ±5% ST Segment Monitoring Range: Measure and Alarm -2.0 ~ +2.0 mV ARR Detecting Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC Alarm: Available Review: Available RESPIRATION Method: Impedance between R-F (RA-LL) Differential Input Impedance: >2.5 MO Measuring Impedance Range: 0.3~5.0O Base line Impedance Range: 0 – 2.5 KO Bandwidth: 0.3 ~ 2.5 Hz Resp. Rate Measuring and Alarm Range Adult: 0 ~ 120 rpm Neo/Ped: 0 ~ 150 rpm Resolution: 1 rpm Accuracy: ±2 rpm Apean Alarm: 10 ~ 40 S
Specifications: Automatic digital upper arm blood pressure monitor Large lcd display High quality Automatic digital upper arm blood pressure monitor Description Upper arm blood pressure monitor Display Lcd digital display Measuring principle Oscillometric method Measuring localization Upper arm Measurement range Pressure 0-299mmhg(0-39.9kpa) Pulse 40-199pulses/min Accuracy Pressure ±3mmhg(±0.4kpa) Pulse ±5% of reading Memory function 2*90 sets memory of measurement values Power source 4 pcs aa alkaline battery or power adapter Automatic power off In 3 minutes Battery life Approx. 300 times for normal condition Accessories Instruction manual, storage box Operating environment Temperature 5-40°c Humidity 15%-85%rh Air pressure 86kpa-106kpa Storage environment Temperature -20°c to 55°c Humidity 10% to 85%rh Avoid crash, sun burn or rain during transportation