400v-40.5kv switchgear
1)6kv-40.5kv raing main unit
2)400v-40.5kv metal clad switchgear
To the future development, with full passion, endless business chanced and development space, we are looking forward to your joining and cooperation to create splendid tomorrow!
Export packing standard
1. Introduction KYN28-12 indoor metalclad withdrawable switchgear is designed to be complete distribution equipment with three-phase A.C. singe busbar and single busbar section system having a rated voltage of 3.6~12kV and rated frequency of 50Hz.The switchgear is mainly employed in receiving and distribution of power energy from the network as well as starting of large-sized HV motors. In addition, the switchgear is provided with controlling, protection and monitoring functions. The switchgear conforms to IEC 298, GB 3906, DL/T404-91 and other standards. The switchgear itself owns five prevention functions such as prevention of misoperation of circuit breakers, prevention of pushing or pulling truck with load, prevention of closing earth switch under voltage, prevention of supplying power when earth switch is at the earth position and prevention of entering the electrical separation zone by accident. The switchgear selects not only VS1 vacuum circuit breakers but also ABB made VD4 vacuum circuit breaders, thus recogninzed as power distribution equipment with excellent performance. 2. Working condition 2.1 altitude: 1000m 2.2 temperature: -10celsius degree ~+40celsius degree 2.3 relative humidity: daily average value 95%, monthly average value 90% 2.4 saturated vapor pressure: daily average value 2.2 10-3MPa, monthly average value 1.8 10-3MPa 2.5 earthquake intensity: less than 8 degree 2.6 protect the product from fire, explosion, earthquake and corrosion atmosphere. 3. Main features: 3.1. the enclosure is completely adopts the aluminum-zinc alloy coated steel sheet, which are machined and bent by machine tool and then bolted; 3.2. all the operations are under the door closing condition 3.3. with high protection category, can prevent intruding of sundries and insects 3.4. simple efficient 5 protection function can prevent operating incorrectly 3.5. the removing compartment of the switchgear may be assembled with VS1(ZN63A) or VD4 vacuum circuit breaker according to customer s demand 3.6. the replacing of VCB is simple and the interchangeability of truck is good. 3.7. the cabinet body can be installed against the wall, so the maintenance can be made in front of the cabinet and the cover area can be reduced too. 3.8. cable compartment has enough room, can connect muti-cable 3.9. high speed earthing switch is used for grounding and loop short circuit 3.10. VCB vault, relay vault and cable vault can add extra heater separately according the demand of customer, in order to avoiding condensation pheromone and corrosion. 3.11. VCB vault and cable compartment can add extra lighting device separately, in order to convenient maintenance. 4. Main technical parameters 4.1 main technical of vacuum switchgear item unit parameter Rated voltage kV 3.6 7.2 12 Rated current A 630 1250 1600 2000 2500 3150 Rated frequency Hz 50 Rated short-time withstand current kA 16 20 25 31.5 40 Rated peak withstand current kA 40 50 63 80 100 Rated power-frequency withstand voltage kV 42/1min Rated lightning impulse withstand voltage kV 75 Rated duration of short circuit S 4 Degree of protection IP4X 4.2main technical parameters of vacuum circuit breaker Item Unit Parameter Rated voltage kV 12 Rated current A 630 1250 1600 2000 2500 3150 Rated short circuit breaking current kA 25 31.5 40 Rated short-time withstand current kA 25 31.5 40 Rated short circuit making current kA 63 80 100 Rated short-time power-frequency withstand voltage kV 42/1min Rated lightning impulse withstand voltage (peak) kV 75 Rated short circuit duration S 4 Closing time (rated voltage) ms 35 t 70 Opening time (rated voltage) ms 20 t 50 Rated breaking times of short circuit times 50 (40kAis 30) Mechanical life times 20000 4.3main technical parameters of operation mechanism Item Unit parameter Rated operation voltage Opening coil V DC220/110 AC220/110 Closing coil Rated operation current Opening coil A (DC/AC)220/110V: 0.9/1.8 Closing coil (DC/AC)220/110V: 1.0/2.0 Power of energy storage motor W 70 Rated voltage of energy storage motor V DC220/110 AC220/110 Energy storage time S 15 5. Structure instruction The basic structure of switchgear panel comprises the panel itself and a removing part (truck). The enclosure and clap-board of the switchgear is bolted with Al-Zn alloy coated steel.Enclosure protection degree of switchgear is IP4X, and the protection degree of every vault is IP2X. 800/1000*1500*2300mm.
Isolator switch (1)inh-100 isolator switch The items can switch on, load and break the current under normal conditions, using as switch disconnectors. The items comply with iec60947-3 & gb14048.3. Rated voltage: 230/400v Rated current: 40, 63, 80, 100a Pole number: 1, 2, 3, 4 (2)it10-100 isolator switch The items can switch on, load and break the current under normal conditions, using as switch disconnectors. The items comply with iec60947-3 & gb14048.3. Rated voltage: 230/400v Rated current: 100a Pole number: 2 Zhejiang inte industrial electric co., ltd. Was founded in 1984 and is iso 9001: 2000 certified. We mainly manufacture circuit breaker, thermal protector, thermostat and counter etc. Electrical and electronic equipments. Some of our products have got ccc, ul, vde, ce, saso approval. Please feel free to contact us your interest. Leave factory packing
WSD-VZF(R) -27/630-25 removable vacuum load switch + fuse combination electrical appliances (hereinafter referred to as combination electrical appliances) is a new generation of three-phase AC 50Hz, rated voltage 27kV indoor switchgear developed according to unique design concept and market demand. It is widely used in indoor armoured air insulated switchgear. It meets the requirements of GB3804-2004, GB16926-1997 and other standards. Under normal operating conditions, as long as the technical parameters of the vacuum switch are within the range, it can ensure the safe and reliable operation of the corresponding voltage level of the power grid. Environmental Conditions for Use The ambient temperature should not be higher than + 40, not lower than 10Â (storage and transportation allowed at 30) Elevation does not exceed 1500m. Relative humidity: the daily average is not more than 95%, the monthly average is not more than 90%, the daily average of saturated vapor pressure is not more than 2.2 x 10-3 Mpa, and the monthly average is not more than 1.8 x 10-3 Mpa. Earthquake intensity does not exceed 8 degrees. No fire, explosion danger, serious pollution, chemical corrosion and violent vibration.
Application:Widely used in: welding machine, washing machines, air conditioners, refrigerators, furniture, thermostats, electric hot water bottle, electric kettles, electric heaters, electric ovens, water heaters, water dispenser, microwave, sterilizer, electric pressure cookers, rice cookers and other industrial and household appliances temperature control products. The Product Sells Point: Key Specifications/Special Features: The company produces mainly thermostat KSD series of sudden jump bimetallic thermostat, Especially in high-power thermostat-oriented products, in this regard there is a lot of experience and a strong research and development capabilities of the company's,, stable temperature performance, high precision, carrying current, synchronous product good. Key raw materials from abroad, with the United States Emerson comparable products. Is currently the only one made by the 60A current CE, TUV, UL, CUL and CQC safety certification. The company produces thermostat varieties, the current from 5A-60A, the voltage from 110V-400V. Existing home but also for industrial use. Technical parameters: AC250V, 400V 15A-60A Temperature range: -20 ? -180 ? Reset Type: Manual reset Safety Certification: TUV CQC UL CUL S ETL performance and the principle of high current thermostat KSD30R series thermostat, with the shell closed bimetal contact temperature temperature relay, thermal expansion and contraction principles of sheet metal bent to reach the set temperature, the disconnect can be manually reset after the temperature drops, appliances from the security role. Large current thermostat product specifications (1) functions: temperature protection and thermal protection, anti-dry (2) Electrical Characteristics: AC125V ~ the 250V/15A ~ 30A ~40A ~50A ~60A ? maximum ambient temperature: 180 ° C (4) Operating temperature range: 0 ° C to 180 ° C (optional). Temperature tolerance: ± 5 ? normal insulation resistance:> 100MO ? normal contact resistance: = 100mO ? service life:> 10,000 high current thermostat Note (1) using the contact temperature installation, the metal cover up snapping charged with the mounting surface of the apparatus. ? installation can not cover up the pressure deformation, so as not to affect performance. (3) To prevent leakage, the use can not allow the liquid to penetrate inside the thermostat, so as not to affect the electrical reliability. ? this product for bipolar wiring method, when used in accordance with the marker, the correct wiring. ? products should be less than 90% relative humidity, ambient temperature below 40 ?, ventilation, clean, dry, non-corrosive gases warehouse store.