Please click here to check who's online and chat with them.

Gvd3Xx Loop Detector

Supplier From China
Jul-08-16

GVD301 vehicle loop detector
Type: single channel
Supply Voltage: 220V AC±10%
Sensing range:20-1500µH
Sensitivity: 0.02%-0.2% (7 degrees adjustable)
Response time: 50ms
Frequency: 2 degree adjustable, 15-120khz
Output: 2 output relays (5A/AC230V) Relay 1: presence relay; relay 2: pulse/fault relay;
CH1: presence relay; CH2: presence relay
Working mode: Model: presence & pulse relay output; Model 2: presence & fault relay output
Presence mode: Limited presence/permanent presence
Pulse mode: pulse entry/ pulse exit;
Pulse output time: pulse entry 200ms, pulse exit 200ms
Presence output time: 30mins limited presence/permanent presence;
Indicator: red: power, green: status indicator;
Internal protection: loop isolation transformer, voltage-regulator tube, voltage dependent thermistance;
Temperature:-40—80 centigrade


Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Gvd3Xx Loop Detector

Jul-29-16
 
Single channel / Dual channel
Standard:AC220V/110V,
Optional:AC&DC 24V/12V
Apr-09-21
 
A fire alarm system is a set of electric/electronic devices/equipment working together to detect and alert people through visual and audio appliances when smoke/fire is present. These alarms may be activated from smoke detectors, heat detectors, water flow sensors, which are automatic or from a manual fire alarm pull station.

Types of Fire Alarm System:
All Fire Alarm Systems essentially operate on the same principle. If a detector detects smoke or heat or someone operates a break glass unit (manual break point), then alarm sounders operate to warn others in the building that there may be a fire and to evacuate. It may also incorporate remote signaling equipment which would alert the fire brigade via a central station.

Conventional Fire Alarm System
In a Conventional Fire Alarm System, a number of call points and detectors are wired to the Fire Alarm Control Panel in Zones. A Zone is a circuit and typically one would wire a circuit per floor or fire compartment. The Fire Alarm Control Panel has a number of Zone Lamps. The reason for having Zones is to give a rough idea as to where a fire has occurred. This is important for the fire brigade and of course for the building management. The accuracy of knowing where a fire has started is controlled by the number of Zones a Control Panel has and the number of circuits that have been wired within the building. The Control Panel is wired to a minimum of two sounder circuits which could contain bells, electronic sounders or other audible devices. Each circuit has an end of line device which is used for monitoring purposes.

Addressable Fire Alarm System
The detection principle of an Addressable System (Fire Alarm System) is similar to a Conventional System except that the Control Panel can determine exactly which detector or call point has initiated the alarm. The detection circuit is wired as a loop and multi devices may be connected to each loop. The detectors are essentially Conventional Detectors, with an address built in. The address in each detector is set by dil switches and the Control Panel is programmed to display the information required when that particular detector is operated. Additional Field Devices are available which may be wired to the loop for detection only i.e. it is possible to detect a normally open contact closing such as sprinkler flow switch, or a normally closed contact opening.

Fire Alarm System comes with single loop as well as multi loops. It depends on requirement. The items which are integrated with Fire Alarm Systems are given belowâ?¦.

Brands are available : AGNI, MORLEY, NOTIFIER,

Modern Technologies gives you top class branded Fire Alarm System with affordable price. We also provide installation & maintenance services.
Dec-21-16
Supplier From Shenzhen, Guangdong, China
Apr-27-16
Supplier From Shenzhen, China
Oct-17-19
 
NAME: Barrier Gate MOTOR MATERIAL: Die-casting Aluminum
COLOR: Blue, Orange And White APPLICATION: Over-sized Traffic Flow Area
CABINET: 2mm Zinc Plated Steel USAGE: Road Traffic Safety
WARRANTY: 1 Year FEATURE: High Durable
SURFACE TREATMENT: Powder Coating
Security gate arms Durable Galvanized/Powder Coating Metal Barrier Gate

Technical Data
Model 102-11 102-13 102-16 102-33 102-26 102-33 102-36 102-46 102-56
Running time 1 sec 3 sec 6 sec 3 sec 6 sec 3 sec 6 sec 6 sec 6 sec
Boom type Straight 90° folding 180° folding 2 fencing 3 fencing
Max Boom length 3 m 4.5m 6m 3m 5m 3m 5m 4.5m 4m
Boom dimension

(WxH)mm

45*80 45*100
Boom weight 3 kg 4.5kg 6 kg 6.5 kg 8 kg 9 kg 11 kg 7 kg 7.5 kg
Voltage 220V±10%, 110V±10%
Frequency 50/60HZ
Motor voltage 220V
Power 80W
Working Temperature -35~+75
Protection grade IP44


Functions & Features

1) Manual realease

2) Machine core with compression spring, effectively avoids the accidents caused by spring breaking;

3) Die-casting aluminum alloy motor, precision and good at thermal radiating;

4) Motor cooling fan, solving the problem of heat-protection;

5) Double safety limitswitches (photoelectricity limit switch/motor memory sensor);
6) Reversing on obstacle;

7) Auto-closing;

8) Support the In frared Photocell for anti-bumping function(optional);

9) Support the external and internal Vehicle Loop Detector;

10) Traffic light interface;

11) Wire Control ( switch signal) / remote control (418 HZ/433 HZ );

12) RS485 Communication module (optional).
SHENZHEN HEPING CENTURY TECHNOLOGY CO., LTD ï¼?PEACENTURYï¼?is a professional security scanner equipment manufacturer, specialized the development and research in the x-ray imagine technology, metal detection technology, explosive detection, liquid detection and relative security services.

We owns all of the intellectual property rights (IPR) to its core technologies ,and have a experience engineer team with senior x-ray detection exports, signal and imagine processing specialist , excellent technical support and maintance engineers.

We always adhere to customer-centric, the principles of honesty and trustworthiness, is committed to efforts to improve and continuous innovate its own responsibility .
Oct-27-17
 
Features:

Safety first: In the fire or power-off,the door can be free to promote and ensure unimpeded;

Various Interfaces:1/O,RS232/485,CAN interfaces,which it is convenient to control interface.

Two working modes:NC and NO,which is easy to deal with peak and normal use

Multiple control modes:There are unidirectional,bidirectional,free passage and authorization passage to meet fully the usersâ?? needs,which consist of nine control modes;

Precise positioning precise positioning by photoelectric sensors,the work cycle of door is regular and precise positioning to ensure correct position after long work;

Various status information:It provides operational status of each component,the prevalent status,abnormal status,etc.

Indicator control:the indicator is able to show three status of front and back indicator (allow through,no through,system maintenance),Also which show the passage direction and passage status (A to pass,B to pass,no through),According to reasonable indicator control,which is convenient for users to management.

Machine core control:the two sides machine core work with coordination and synchronization,and the control system provide convenient management functions,the passage controller can control the machine core of all functions and settings of all parameters,which is reasonable for consisting of the various components of the machine core operation flow,and which is more intelligent and safety to design a access control function;

Sensor Analysis:The sensor got signal which real-time processing and analyzing a person or object for a variety of action,according to the results of analysis are to accurately control the action of machine core,indicator and alarm etc.

Sound output:Whether it is normal or emergency situation,the sound output can remind passengers and administrators timely and friendly.witch cooperate with light and make the perfect effects.

Convenient settings: With the screen and buttons consist of human-machine interface,the users can quickly and easily query and set channel parameters,no longer totally dependent on the host computer or extremely unfriendly pure key board to query and set parameters.This is not necessary functions,but once experience we believed that no one will forget it is great.

Automatic test:In the man-machine interface,system provides automatic test function,which can be a well test whether the components to work properly or not;

Technical:

Size:L1400xW160XH960(MM)

Material:304s/s,1.5mmthickness;

Passage Length:600mm

Flap material:10mmPVC material;

Passage width
Oct-27-17
 
Function

1. High speed,stable running speed can be adjusted, devoted to electronic toll collection systems ETC

2. Using professional digital stepper motors, can be run at low or high speed stable operation

3. Can prevent car features: rail arm falling to angles greater than 15 ° horizontally within the context of, such as vehicular coil induction area, Rails will automatically lift the arm to prevent smashing cars;

4. Anti-collision function: the rail arm and main shaft is arranged between the turning device of rail, the rail arm crash occurs, it will take away;

5. Barrier arm will automatically lift once Power brake.

Technical

ItemParameter

Arm length2.0 m

Arm raising speed 0.3~0.8 seconds

Voltage220V ±10%

Frequency50/60 Hz

Power500 W

Size418*386*1085 mm mmmm(L*W*H)

Remote distance10~30 m

Net weight(Not include arm)75 Kg

MotorDigital Stepper Motor

Using life10 million times
Oct-20-16
 
Sna-360 analogue addressable photoelectric smoke detectors are microprocessor controlled state-of-the-art detectors
Compatible with popular control and indicating equipment loop protocols.
Advanced electronics in conjunction with a photoelectric smoke sensing chamber provides early detection of fire and
High immunity against unwanted alarms.
Photoelectric smoke sensor
Analogue detection discrimination
Dual leds for 360° visibility
Dc 24 v operation
2-wire connection to many popular loop protocols
Dip switch address setting
125 usable detector address settings per loop
Optional remote led output
Oct-20-16
 
Hna-360 analogue addressable heat detectors are microprocessor controlled state-of-the-art detectors
Compatible with popular control and indicating equipment loop protocols.
An electronic thermistor sensor provides sensitive rate-of-rise alarm operation, or fixed-temperature operation
When the response threshold value is exceeded.
Durable heat sensor
Analogue detection discrimination
Dual leds for 360° visibility
Dc 24 v operation
2-wire connection to many popular loop protocols
Dip switch address setting
125 usable detector address settings per loop
Optional remote led output

Verification Status