Introduction:
Esd simulator (electrostatic discharge generator or electrostatic gun) is in full compliance with iec 61000-4-2, en61000-4-2, iso10605, gb/t17626.2, gb/t17215.301 and gb/t17215.322. The esd generator is designed for the assessment of electrical and electronic equipment to withstand esd performance. Esd61000-2/esd61000-2a has lcd display in both english and chinese, they equipped with an infrared remote control which can allow you do the test in some special place.
Specifications:
Product model
Esd61000-2
Esd61000-2a
Output voltage
0.1~20kv±5%
0.1~30kv±5%
Polarity
Positive/negative
Positive/negative
Energy storage capacitance
150pf±10% (replaceable)
150pf±10% (replaceable)
Discharge resistor
330o±5% (replaceable)
330o±5% (replaceable)
Current rise time
0.6~1ns
0.6~1ns
Testing functions
Single, count, 20pps, air, contact, iec level
Single, count, 20pps, air, contact, iec level
Trigger mode
Manual/auto
Manual/auto
Numbers of discharge
1~9999
1~9999
Repetition
0.05s~99.99s
0.05s~99.99s
Working power
Ac220v(option 110v)±10%, 50/60hz
Ac220v(option 110v)±10%, 50/60hz
Touch screen with super big lcd and built-in windows ce
Calibrate report:
Output voltage (kv)
First peak current (a)
Current at 30ns (a)
Current at 60ns (a)
Rise time (ns)
2
7.29
4.10
2.20
0.93
4
15.40
7.90
4.30
0.97
6
23.20
12.10
6.50
0.97
8
29.40
16.20
9.30
0.89
-2
7.39
3.50
2.30
0.92
-4
15.50
7.70
4.30
0.89
-6
23.40
11.90
6.30
0.90
-8
31.80
16.10
8.20
0.90
Note: metal holder needs extra cost.
1. The structure and working principle of hydraulic transmission and components; 2. Demonstration control experiment of hydraulic bulldozing machinery; 3. Demonstration control experiment of hydraulic bulldozer 4. Shoveling action of hydraulic bulldozer; 5. Earth-moving action of hydraulic bulldozer; 6. Unloading action of hydraulic bulldozer; 7. The hydraulic bulldozer returns when it is empty;
1, sensor detection 2, the basic use of the drive 3, timer instructions 4, mathematical instructions 5, high-speed counter 6, car automatic switch door control 7, elevator simulation run call indication driver 8, floor display 9, door machine torque safety protection 10, hall door security control 11, elevator terminal switch protection 12, elevator lift deceleration control 13, the use of photoelectric encoder positioning
1, escalator armrest installation and adjustment of practical training equipment 2, ladder ladder installation and adjustment of practical training equipment 3, escalator traction machine system installation and adjustment of practical training equipment 4, ladder drive mechanism installation and adjustment of practical training equipment 5, escalator mechanical anti-reversal system, electrical anti-reversal system installation and commissioning training equipment 6, ladder lubrication system assembly and experimental training equipment 7, ladder safety protection system assembly and action experiment training equipment.
1, to understand the structure of escalators, tightening device, rungs, ladder rails, armrest straps, traction chain, comb plate, drive device and other major components name and role. 2, to understand the role of escalator installation protection device, installation position includes: traction chain break protection device, armrest belt entrance safety protection device, ladder subsidence protection device, drive chain break protection device, armrest belt break protection device, brake, mechanical locking device. 3, the basic safety operation and use of escalators; 4, rung disassembly operation; 5, comb plate adjustment; 6, comb cutting-edge plate adjustment; 7, armrest tight adjustment; 8, the adjustment of rung chain tension; 9, the adjustment of the drive chain; 10, escalator anti-reversal mechanical experiments; 11, upper and lower traction chain safety experiments 12, host chain-breaking safety experiments
1, let students familiar with the industrial commonly used sidewalk escalators working principle, structure composition, low-voltage electrical structure and principles. 2, through the analysis of electrical schematics, students with the help of schematic analysis, master the safety protection and working form of elevators, and through analysis and measurement, to find out the location of fault points, a deep understanding of the operation of elevators. 3, improve the actual hands-on analysis ability of students, and actually improve the level of skill operation. 4, through the analysis and elimination of elevator faults, to complete the common elevator fault cognition and understanding. 5, through the PLC host programming, understand the PLC program programming principles and methods. 6, escalator safety operation and use of practical training 7, rung disassembly operation and practical training 8, comb plate adjustment and practical training 9, armrest belt tension adjustment and practical training 10, rung chain tension adjustment and practical training 11, brake adjustment and practical training 12, maintenance before the safety knowledge operation and practical training Daily maintenance 13, escalator emergency rescue 14, escalator safety circuit fault finding and troubleshooting practical training 15, escalator access circuit fault finding and troubleshooting training 16, escalator safety monitoring circuit fault finding and troubleshooting training 17, escalator power circuit fault finding and troubleshooting practical training 18, escalator control circuit fault finding and troubleshooting training
This mini portable air conditioner can use a battery to be taken outdoor. This portable air cooler can be used also for your pets during summer. You can use portable battery or just charge it via USB. It is very economic as the the electricity that uses is only 2.5 watt. Measurements: 13.1*13.1*17cm Weight: 650 g. It has a water tank of 450ml that can be used for 4-6 hrs. Use battery of bigger than 10,000 mAh.
From our extensive range of electrical products, we manufacture and export a supreme quality range of tubular man cooler fans that is provided with aerofoil type impellers. Offered in bracket, tubular and pedestal type model, these fans are suitable for Foundries, Factories & Machine shop and is used in various industries for cooling purposes and dust & hot air removal. These cooler fans are manufactured using superior grade components and pioneering technology under the guidance of our skilled professional as per industry norms. Our cooler fans are quality approved by our experts on various parameters. Further more, we offer this tubular man cooler fans in different technical specification affordable rates. Man coolers (wall mounting, pedestal) consist of specially designed aerofoil impeller cast in aluminum alloy, coupled directly on motor shaft the motor with the impeller assembly is mounted on a cradle. Tubular Provision is made for adjusting the angle of air stream these fans are portable in nature and can be made to stand even on rough surfaces. A long casting for the impeller system provides an effective means of canalizing air stream in any desired direction. Wall mounting these fans can be mounted on the wall or on column to save floor space. Provision is made for varying the direction of air stream, both vertically and horizontally by providing a false ceiling head arrangement. Pedestal type the entire assembly is mounted on a steel column and fitted on the heavy base. These are portable in nature.
*Features: - Best Engineering Plastic Injection - Molding Body - UV - Resistant Cabinet Material - 100% Usable in Outdoor *Best high torque motor - 100% maintenance free - 100% dust & moisture proof - Serves upto 80% Electricity Bill - Can be used non stop up 24 Hrs. *How it works? Evaporative cooling is a physical phenomenon in which evaporation of a liquid, typically into surrounding air, cools an object or a liquid in contact with it. Latent heat describes the amount of heat that is needed to evaporate the liquid; this heat comes from the liquid itself and the surrounding gas and surfaces. When considering water evaporating into air, the wet-bulb temperature, as compared to the air\'s dry bulb temperature, is a measure of the potential for evaporative cooling. The greater the difference between the two temperatures, the better the evaporative cooling effects. When the temperatures are the same, no net evaporation of water in air occurs, thus there is no cooling. *Applications : - Plant or Factory - Leather Industries - Showroom - Farm House - Canteen - Warehouse - Prining Press - School, Colleges, Office - Plasic Moulding Industry - Iron Industry - Engineering Industrial - Electronics Industry - Hotel & Restaurant - Paper Industries - Textile Industries *Extraordinary features & benefits of BlowTech Air Washer Unit -5090 Honey Comb - Cellulose Wet Pad# World\'s Best Quality Pads imported from Finland with Anti Bacterial Resins & 4X Longer Life than any other Pad (last upto 5 yrs.*) 4D Technology (Top & Bottom Discharge) - BLOWTECH is the only brand which gives 4D Cooler in movable & ductable Coolers. Turbo Axial Fan# - BLOWTECH is the only brand which gives Turbo Axial Fan for worlds most powerful air through & very low noise
Blowtech Door air curtain is a fan powered device that creates an invisible air barrier over the doorway to separate efficiently two different environments, without limiting the access of the people or vehicles. The energy saving air screen reduces heating and cooling costs by up to 80% while protecting the internal climate and increasing people comfort. It keeps the atmosphere clean from pest and insects, dust, airborne, pollution, smells, odors and stops drought and cold or hot air entrance. Our range of Industrial Door Curtains that we manufacture are controlled by switch, designing is direct ventilation. Dual airflow creates an effective air barrier. *We manufacture 3 different models & it depends on door height. 1. Blowtech \"Alfa Model\" (upto door height 8 fts) 2. Blowtech \"Alfa Model\" (upto door height 12 fts) 3. Blowtech \"Alfa Model\" (upto door height 22 fts) *Blowtech air curtain advantages - Helps maintain adequate environment - Pest and insect control - Increases customers and staff comfort - Act as a barrier against fire smoke (special application) - Easy evacuation through the exit doorway in case of fire or emergency - Barrier against airborne dust, pollution, fumes and bad odours *Applications: - Factories - Workshop - Warehouses - Agricultural Applications - Schools - Hotels - Change Houses