Single-use visual impact indicator mounted directly to product packaging. Activates when exposed to impact beyond desired threshold and turns bright red to indicate mishandling.
Single use, go/no go devices that determine if fragile products have been dropped during transit or in storage. Field-armable, tamper-proof devices that turn bright red when an impact beyond a specific threshold has occurred. Each unit has a unique identifier to support traceability.
SANDI SERIES charging module is for electric vehicle charging station. With single-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic. Functional details 1. Hot plug Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system. 2. Advanced current sharing technology Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than �±0.5A. 3. Control of input limited power Refer to Fig. 1-10 for the relation between the output power and input voltage of the charging module. When the input voltage is within 360 Vac ~ 450 Vac (return difference is less than 5V), the module can output the maximum power of 20 KW; when the input voltage is within 260 Vac ~ 320 Vac, the module can still work normally under limited power mode. 4. Control of output constant power When there is a rated input voltage, the output power of the module is 20 KW. Refer to Fig. 11 for the relation between the output voltage and the output current of the module. The SD75050 module uses two operating modes with output voltage ranges of 50 to 750V. The module only selects the operating mode based on the value of the received demand voltage, and does not select the operating mode based on the actual output voltage. 5. Temperature limited power 6. Regulation of output current limiting point 8. Regulation of output voltage The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 750Vdc and minimum regulation step of 0.1 Vdc. 9. Fan control The built-in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module. 10. Protection of input overvoltage/ voltage shortage 11. Output overvoltage protection The overvoltage protection point is 260Vdc ~770Vdc (�±10 Vdc). Default is 778Vdc.The module can be started after manual intervention upon overvoltage protection. 12. Over-temperature protection The environmental over-temperature protection point is 80�°C. When the DC panel has a temperature over 100�°C, the module will stop working; when the DC panel has a temperature below 90�°C, the module will automatically work again. 13. Protection of internal bus fault When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on. 14. Short circuit protection In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the "module fault".
CORE COLOUR: As per IS: 694:2010 - 2-CORE - Red, Black / 3-CORE - Red, Yellow, Blue / 4-CORE - Red, Yellow, Blue, Black As per IEC:60227 - 3 CORE - Blue, Brown, Black or Yellow/ Green / 4 CORE -Blue, Brown, Black, Grey or Yellow/Green, COPPER: EC flexible copper generally conforms to IEC 60228, DIN VDE 0295, IS 8131, INSULATION: Special grade of Rubber EPR, EPDM for inner & outer, TECHNICAL DATA: WORKING TEMPRATURE : -20�° C to + 70�° C, VOLTAGE RANGE : UP TO 1100 V, TEST VOLTAGE : 3000 V, MINIMUM BENDING : 6 X cable diameter, APPLICATION: Drinking Water Supply Pumps, Irrigation of water, appliances, control panels, machinery, and industries of every nature, SPECIAL FEATURES: Excellent Impact Resistant, Excellent Weather Resistant, PACKING: 500/1000 meters on drums.
Shockwatch tip and tilt sensors continually monitor and/or report the conditions products are exposed to during transit, storage, and operation. Attach one of the tiltwatch family of products directly to a package or container’s exterior surface, to monitor the ‘care in handling’. Tiltwatch xtr tip indicator monitors goods that must remain upright to ensure intact delivery. Tiltwatch xtr is a single-use tip indicator that does not activate until it is at an 80o angle +/-5% from vertical. Tiltwatch plus attached to package’s exterior surface, ‘peel and stick’ pressure sensitive label, is actually three separate registers in a single tilt indicator unit, providing inexpensive 360° tilt monitoring for the entire duration of shipping transit and an unalterable record of damaging excesses.
To facilitate the clients, further we are offer authentic range of impact & environmental recorders that is used for recording varied environment conditions during transportation, storage as well operation. These recorders are assembled and incorporated with latest gps / gprs tracking module required to record any kind of impact and generate reports so as to decrease the rate of products damaging. The various environmental factors like humidity, temperature changes, till and atmospheric pressure can be recorded in this devise and can be rectified to reduce the damaging of the products. They are capable of recording shock, vibration or any environment related impact conditions and can exactly record the time duration of the mishandling. These devices are incorporated with advance triaxial piezoelectric accelerometer technology is used for recording the exact amplitude and direction of impact that enables to set certain control measures to prevent the products from damaging further.
The skid-mate is an air dampened cushioning device that provides a fast, cost effectiveand durable customized solution to protect sensitive products from shock and vibration. Theskid-mate can be easily mounted on a crate or pallet base creating an air-ride cushion in placeof hardwood skid runners eliminating the need for expensive air-ride trucks.Each color coded skid-mate corresponds to a specific load range and allows users to calculatetheir requirements simply and easily to avoid potential laboratory testing and use of expensivepackaging materials. Reduce packaging design & assembly time and cost• eliminate costly damage from handling hazards during shipment• reduce costs associated with shock and vibration damage
Supplier: Impact indicators, shock recorders, temperature indicators, safety cutters
1. Versions - PID - Single loop (Includes Onoff Controller and Indicator modes) - PID - Dual loop - Heat+cool - PID - Single loop, 16-segment profile - VMD 2. IP66 (IEC) / NEMA 4X protection 3. 1 or 2 universal inputs 4. Sampling time 50ms/200ms programmable 5. Upto 6 digital inputs 6. Upto 7 setpoints (2 control relays, 5 alarm relays) 7. Isolated 2 x 0/4~20 mA or 0-10 V DC for control / retransmission output 8. Isolated RS485/Modbus RTU 9. Autotuning function 10. Auto/manual control 11. Calibration & configuration through PC utility 12. User friendly keyboard interface with password protection 13. User key with assignable function
B series temperature and humidity controller with completed FUZZY algorithm control fan or heater to maintain sensible & latent capacity follows temperature curve by automatically. And have an independent humidity input can monitor the environment RH and output control signal. User can adjust temperature value very easily to use dial and a LED indicator to show the relay. -. Electromechanical thermostat, max with 2 control port for fan & heater -. Dial pad setting temperature / humidity threshold -. Sensor length max 10meter (default 3meter) -. 48*48mm panel mounting size, optional Din-rail mounting rack
B series temperature and humidity controller with completed FUZZY algorithm control fan or heater to maintain sensible & latent capacity follows temperature curve by automatically. And have an independent humidity input can monitor the environment RH and output control signal. User can adjust temperature value very easily to use dial and a LED indicator to show the relay. FEATURES Electromechanical thermostat, max with 2 control port for fan & heater Dial pad setting temperature / humidity threshold Sensor length max 10meter (default 3meter) 48*48mm panel mounting size, optional Din-rail mounting rack