Rotatory plate optical sorting machine
Machine's Character:
* Quick & easy to chnage different specifications.
* Friendly interface for setting measurement items.
Adaptable Product:
Screws, rivet and product can be hung well on the plate.
Inspection items:
1.Roundness
2.Major diameter
3.Minor diameter
4.Spiral angle
5.Pitch
6.Necks down length
7.Included angle
8.Head thickness
9.Head diameter
10.Head crack
11.Hole diameter.
Rotatory glass plate optical sorting machine Machine's Character: * Measurement for simultaneous top/bottom inspection. * Also suitable for tiny electronic parts. Adaptable Product: O-ring, seal, packing and product can stand stably on the glass surface. Inspection items: 1.Hole diameter 2.Concentricity 3.Thickness 4.Crack 5.Color 6.Surface Stain 7.Bubbles 8.Burrs.
Fastener, nuts sorting machine Machine's Character: * Variety of inspection modules satisfied for the most of inspect needs. Adaptable Product: Nuts, rivet, roller, washer, stud, set screws and products can stand stable on the belt. Inspection items: 1.Thread 2.With coating 3.Hole diameter 4.Outside diameter 5.Concentricity 6.Roundness 7.Overall height 8.Deformed 9.Crack 10.Marking 11.Width/length 12.Thickness.
Eddy current sorting machine Inspection items: 1. Recognition of hardness difference , accurancy 2 HRC ( +/- 1HRC) 2. Recognition of different metal material mixed. 3. Same size with similar material parts mixed 4. With/without high frequency harding difference. 5. Dimension measurement of appearance by laser or optic ( extra optional) 6. crack sorting (extra optional).
1.Vacuum chamber size| H1500mm,which is made of high grade 304 stainless steel ,inner surface by polishing treatment, surface with cooling water jacket,postposition pumping system vertical front opening door structure,viewing window installed in the door,and equipped with glass panel,vacuum chamber stainless steel plate thickness 1mm ,convenient to clean and maintain,up cover board installed lifting rings,in bleeding point there installed electric throttle flap,and 1 pcs KF40 deflation valve. 2.Substrate holder speed 330rpm AC variable frequency speed regulation(Korea LG) up driven way.Workpiece plate axial and radial runout 2mm;ferrofluidic seal,Bearing adopts Japanese NSK whole substrate holder structure adopts 304 stainless steel. 3.Vacuum pumping system 2sets 28inches diffusion pump+ 1set British Edward Monoblock pump275+1setBritish Edward roots pumpEH2400 and high vacuum pneumatic baffle valve form fast and efficient vacuum pumping system which can meet pumping requirements during coating.Equipped with compound vacuum gauge,which used for measuring high and low vacuum degree.Between valves there is safety interlock to make sure equipment safety use. 6.Vacuum chamber heated by electric heating tube,which can realize automatic control temperature. 7.Equipment base use merchant steel made,surface spray paint, open the door, beautiful decoration.
Supplier: Eddy current sorting machine, optical sorting machine, fastener sorting machine, screws, bolts sorting machine, nuts sorting machine, oil seal sorting machine, washer sorting machine
2D optical measurement instrument Machiner Properties: Saving over thousands of specifications, simply one lesson will do, easily click to load the related setting data. Rapid measurement and the measurement result can be able to save for analysis or inquiry purpose. Well apply to at-site inspection, sampling inspection for Q.C. and before delivery. Inspection items: 1.Hole diameter 2.Diameter 3.Concentricity 4.Roundness 5.Straight line distance 6.Center distance 7.Straightness 8.Perimeter 9.Area .
Fusion splicer pt-630 Features Fiber core can be display clearly Singlex or y view and x & y view simultaneously Auto check quality of cleaved end face Auto select best splicing program 9 seconds splice time and 30 seconds heat time Small bulk and light weigh 5 inch color lcd monitor with clear digital image display Simple operation menu Software upgrade via usb interface Specification Model Pt-630 Applicable fibers Sm (itu-t g.652), mm (itu-t g.651), ds (itu-t g.653), nzds (itu-t g.655) Fiber cleaved length 12~16mmú¿coating diameterú¦250ª8mú¬ 16mmú¿coating diameter: 250 ~ 1000ª8mú¬ Fiber diameter Cladding diameterú¦80 ~150ª8m Coating diameterú¦100~ 1000ª8m Fiber count Single Fiber aligning method Core aligning Image processing method Digital Actual average splice loss 0.02db ú¿smú¬, 0.01db (mm), 0.04db (ds), 0.04db( nzds) Splicing time Typical 9 secú¼with standard sm fiber Splicing mode 53(templet), 40(user) Splice loss estimate More accurate Return loss ú+60db Storage of splice result 5000 resultsú¼3 parameter per result Fiber display and magnification 400xú¿x or y viewú¬, 200xú¿x and y viewú¬ Tube heating time Typical 30 sec Tube heating mode 9(templet), 24(user) Tube heating temperature Can be adjusted Applicable protection sleeve length 60mm, 40mm and a series of micro sleeves Tension test 2n Electrode life 2500 No.Of splice/heating with battery Typical 130 cycles (splice/tube heat) with inner li-battery Display screen 5 inch color lcd monitor Image change over The fiber image is turned upside down Terminals Rs 232 Operating condition 0 ~ 5000m above sea level, 0 ~ 95%rh and -10í½50íµ, respectively, max. Wind velocity of 15m/s Power supply Ac 100-240v with ac adapter; inner li-battery(6600mah) Dimensions 150mm(l) x150mm (w) x150mm (h) Weight 2.7 kg excluding battery, 3.2 kg including battery
Fusion splicer pt-650 Features Equel to fujikura fsm-50s, sumitomo type-37 etc Core to core alignment by pas technology ( pas:profile alignment system) Digital fusion splicer with automatic focus function Fiber core can be display clearly Single x or y view and x & y view simultaneously Auto detect cleaved endface fault Display fiber cleaved and offset angle Display core and clad offset 5.6 inch tft color lcd monitor with clear digital image display Usb & vga interface Software upgrade via usb interfac Specefication Model Pt-650 Applicable fibers Sm (itu-t g.652), mm (itu-t g.651), ds (itu-t g.653), nzds (itu-t g.655) Fiber cleaved length 12~16mmú¿coating diameterú¦250ª8mú¬ 16mmú¿coating diameter: 250 ~ 1000ª8mú¬ Fiber diameter Cladding diameterú¦80 ~150ª8m Coating diameterú¦100~ 1000ª8m Fiber count Single Fiber aligning method Core or clad aligning Image processing method Digital Actual average splice loss 0.02db ú¿smú¬, 0.01db (mm), 0.04db (ds), 0.04db( nzds) Splicing time Typical 9 secú¼with standard sm fiber Splicing mode 53(templet), 40(user) Splice loss estimate More accurate Return loss ú+60db Storage of splice result 4000 resultsú¼20 parameter per result Fiber display and magnification 300xú¿x or y viewú¬, 150xú¿x and y viewú¬ Tube heating time Typical 30 sec Tube heating mode 9(templet), 24(user) Tube heating temperature Can be adjusted Applicable protection sleeve length 60mm, 40mm and a series of micro sleeves Tension test 2n Electrode life 2500
Supplier: Optical accessory, silicone nose pads, silicone temple tips, screws, injection temple and bridge