Power correction factor device corrects reactance losses from large inductive loads. Reverses reactance loss in power efficiency resulting in lower amperage requirements after lock rotaor current phase od staritng inductive loads.
9z9x7" boxed each unit, lot sizes dependent on rate of purchase and shipping requirements. Components are top of the line and product will operate in any electrical environment 120, 220 , 3 phase another unit. Savings range from 10- 40% depending on age of equipment. Equipment will run more efficiently and service requirements for equipment will be reduced significantly
UNIVERSAL MODEL æSHEPHERDÆ E.C. unit (Energy conservation unit) Universal model is designed with basic concept of saving on æEnergyÆ. It has inherent capability to save Energy around 22% to 26%, it has shelf life of 15 to 18 years and simple to operate and suitable to deal with unbalance load. It contents a set of extremely low loss, specially designed for energy saving application, impedance coils. The efficiency of these device is >98.8%. The combination of core design and Impedance coil construction is matched in such a way that it practically generates zero heat, noise and vibration. The E.C. unit is provided with suitable taps to manage output voltage according to the requirements of location. The selection of voltage can be done by Tap changing switch in ON LOAD condition. The E.C. unit is also having inbuilt protection of MCCB/ MCB, mains indicator lamps and ample place for Input/output cabling arrangement. It has digital voltmeter - Amp meter (VAF Meter) on in put side and digital volt meter (V Meter) to read Phase to phase & phase to neutral voltage and phase to phase current (thruÆ VAF Meter). It also has arrangement of on load Manual BY-PASS. Under this arrangement, in case of any failure in the E.C. unit, the entire supply can be put on to æBy PassÆ mode through switching. This allows continuation of power supply to lighting load directly from main line even if E.C. unit fails or kept for servicing, repair, maintenance etc. E.C. unit Universal model is suitable for indoor /outdoor locations. This can be supplied in Natural Air cooled, Forced Air cooled, Natural Oil cooled version, as per userÆs requirement. The SHEPHERD ENERGY CONSERVATION UNIT Universal model can also be optionally supplied with digital KWH meter Energy analyzer, SFU, etc. various accessories and fittings upon request. The Universal model is basically simple design; include all basic features and having lowest Pay Back period, most economical price wise, suitable for all kinds of lighting loads. List of standard accessories and fittings along with other details related to said product is attached herewith. The equipment is time tested at many many types lighting loads & is rugged, totally maintenance free, compact, elegant and silent. Varies from capacity to capacity
Sn 200g is high performance vector inverter for general purpose with low speed and high torque output.It has very dynamic characteristics, providing rich expanding supports.(it supports pg cards, terminal expansion cards, professional special machinery cards and a variety of communication protocol cards).Sn200g has expanded the control functions for the closed-loop vector, optimized the performance of dsp main control, and provides more expanding supports in this business. Supply ability:100000 set/sets per month Port:shanghai or ningbo Place of origin:zhejiang, china (mainland) Brand name:safesave Model number:sn200g three-phase Output power:0.75-630kw Output type:triple Size:186*125*159mm-1300*815*424mm Weight:1.7kg-300.6kg Input voltage:380v Output voltage:0-380v Type:ac/ac inverters Output frequency:0-3200hz Output current:2.1a-304a Certification:ccc, ce, iso9001 Protective class:ip20 Warranty:18 months Control mode:speed sensor vector control Field bus:modbus can link Communication port:rs 485 Packaging details:standard export packing Delivery detail:wthin 30 days
Supplier: Special Equipment, Petrochemical Refining Plant, Excavator, Electric Shovel, Tunnel Boring Machine,Shield Tunneling Machine, Electric Heavy Truck,Large Casting And Forqing,Wind Power Generation, Petroleum Storage Tank, Large Boiler, Frequency Converter,Energy Storage Type Converter,Nuclear Power Equipment,Breathing Machine.
Supplier: Energy conservation units which guarantees savings from 20-30% (power savers), transformers, APFC, CVT, stabilizers, 24 v safety hand lamp
Product Description: 1.IEC ISO Certification. 2.Power Transformers . 3.Low noise, environmental protection. 4.Low no-load loss ,energy conservation. Product Description: 1.IEC ISO Certification. 2.Power Transformers . 3.Low noise, environmental protection. 4.Low no-load loss ,energy conservation.
Product Details Full steam generator using natural magnet copper float level controller, regardless of antioxidant water quality, waste heat recovery 2 times longer life, saving over 30%. Safety, energy conservation, environmental protection, adjustable automatic electric steam generator Equipment Features: 1.This equipment no noise, no pollution, environmentally-friendly, clean, long life. 2.Compact structure compact, and flexible installation, small footprint. 3.High thermal efficiency, energy saving, low operating costs. 4.There are multiple electrical protection and mechanical protection, security measures to improve, safe, stable and reliable. 5.Over pressure, water and other failure operation, immediately cut off the main circuit power supply, to ensure personal safety equipment, and audible alarm signal. When the water level rose 2L machine automatically heated, add to the maximum level is automatically closed. Product Usage: The equipment and dry cleaning machines, washing machines, ironing Equipment washing machine, iron and other supporting; electric steam generator is the use of electric hot water is converted to steam equipment. Internal heating element is inserted in the cylinder, the power to make the barrel body of water temperature, saturated steam to produce hot water. At the top of the cylinder has a steam valve or valve, safety valve, pressure gauge, pressure controller, water level sensors in the lower cylinder has intake, outfall, fitted to the pump on the base, with pipes, valves to it communicates with the cylinder. The products are widely used in the chemical industry, machine repair, footwear, textiles, packaging, factories, offices, hospitals, canteens, hotels, guest houses, restaurants and other places, to provide users with the production of the required life of small-capacity steam.
Technical Specification Chart: Parameter 1 - Phase 2 - Phase 3 - Phase Unbalanced Air Cooled 3 - Phase Balanced Oil Cooled 3 - Phase Unbalanced Oil Cooled Energy Conserved Lighting Load Centralized Stabilizer for offices & residence Rating (KVA) 1 - 20 0.5 - 20 3 - 100 3 - 200 3 - 250 3 - 500 3 - 500 I/P Voltage range (V) 170 - 270 195 - 265 340 - 480 240 - 480 340 - 480 360 - 460 310 - 480 340 - 460 360 - 460 340 - 480 360 - 460 310 - 480 340 - 480 360 - 460 310 - 480 340 - 480 360 - 460 O/P Voltage (normal) 230 V 415 V 415 V 415 V 415 V 208 V LN 220 V / 230 V LN Alternate O/P setting 220 V / 240 V 380 V / 400 LL 220 V LN 220 V / 230 V LN O/P V regulation ± 1% of nominal output voltage O/P V Indications Digital voltmeter, accuracy 1% of FS ± 1 digit LED Indications Front panel LED Indicators, Input ON, output ON, Input high / Low, output High / Low trip Under over voltage trip Electronic cutoff circuit with graded time delay set @ + 5% / -10% of nominal voltage Over Load cut off Electronic cutoff circuit with graded time delay set @ 110% of rated full load current Short circuit protection HRC fuse / MCB at input Single phasing prevention Not applicable Provide Individual phase cutoff only Service bypass Not provided Provide upto 100 Kva. 3 phase Individual phase bypass provided up to 50 kVA 3-ph Resetting mode Automatic restart with time delay mode of 15 sec. (optional).
Technical Specification Chart Parameter 1 - Phase 2 - Phase 3 - Phase Unbalanced Air Cooled 3 - Phase Balanced Oil Cooled 3 - Phase Unbalanced Oil Cooled Energy Conserved Lighting Load Centralized Stabilizer for offices & residence Rating (KVA) 1 - 20 0.5 - 20 3 - 100 3 - 200 3 - 250 3 - 500 3 - 500 I/P Voltage range (V) 170 - 270 195 - 265 340 - 480 240 - 480 340 - 480 360 - 460 310 - 480 340 - 460 360 - 460 340 - 480 360 - 460 310 - 480 340 - 480 360 - 460 310 - 480 340 - 480 360 - 460 O/P Voltage(normal) 230 V 415 V 415 V 415 V 415 V 208 V LN 220 V / 230 V LN Alternate O/P setting 220 V / 240 V 380 V / 400 LL 220 V LN 220 V / 230 V LN O/P V regulation ¦ 1% of nominal output voltage O/P V Indications Digital voltmeter, accuracy 1% of FS ¦ 1 digit LED Indications Front panel LED Indicators, Input ON, output ON, Input high / Low, output High / Low trip Under over voltage trip Electronic cutoff circuit with graded time delay set @ + 5% / -10% of nominal voltage Over Load cut off Electronic cutoff circuit with graded time delay set @ 110% of rated full load current Short circuit protection HRC fuse / MCB at input Single phasing prevention Not applicable Provide Individual phase cut off only Service bypass Not provided Provide upto 100 Kva. 3 phase Individual phase bypass provided upto 50 kVA 3-ph Resetting mode Automatic restart with time delay mode of 15 sec. (optional)
As the most widely used power facility, power transformers have a wide variety of types and are of great significance to energy conservation and emission reduction. The S13 fully-sealed oil-immersed power transformer is currently the main selection product for power distribution equipment, with significant energy-saving effects. At present, mainstream distribution transformers generally use S13 laminated core power transformers. It adopts a fully oil-filled sealed type, no oil conservator, and a corrugated sheet box structure. The volume of the transformer changes due to changes in temperature and load, which is completely adjusted by the corrugated oil tank. Its no-load loss is much lower than that of S9, and it is resistant to lightning impact It has strong short-circuit resistance, obvious energy-saving effect, and reduces the overall size of the transformer. The S13 transformer is made of high-permeability oriented silicon steel sheet with a thickness of 0.27-0.30mm and a unit iron loss of 1w/kg, while the new S9 type is an ordinary silicon steel sheet with a thickness of 0.30-0.35mm and a unit iron loss of 1.20 -1.55w/kg. The S13 distribution transformers produced by our company all use 30P series high-permeability oriented silicon steel, using foil-wound coils and new insulating materials and processes. The product is resistant to high temperature, impact, and fully sealed structure design to ensure the stability of transformer oil quality It prolongs the maintenance cycle. At the same time, the integral fuel tank composed of corrugated fin radiator is produced by phosphating and multi-layer anti-rust spraying process, which has good weather resistance.