Please click here to check who's online and chat with them.

Lm-79 Moving Detector Goniophotometer

Supplier From China
Nov-27-23

Measurement:
Luminous Intensity Data, Photometric Data, Luminous Intensity Distribution, Zonal Luminous Flux, Luminaries Efficiency, Luminance Distribution(Option), Coefficient Of Utilization, Luminance Limitation Curves Glare, Maximum Ratio of Distance to Height, Equal Illuminance Diagrams, Curves of Luminaires VS Lighting Area, Isocandela Diagrams, Efficient Luminescence Angle, EEI, UGR, etc.

Features:
he near field detector moves together with the big mirror in a line. The big mirror and the far field detector move synchronously.The burning position of the lumainares will be kept without moving at all, and the detector will always sense the light directly from the luminares.
The rotary motor is from Japan MITSUBISHI MOTORS and the angle decode system is from Germany. They help the goniophotometer rotating smoothly with high accuracy. It is very stable when start and stop.
The working principles are according to IESNA and CIE. The LSG-6000 completely meet the LM-80, LM-79, LM-75, GB, EN and CIE121-1996 standards.
Special collimation device with cross laser line help you installing the position of the luminaires under test conveniently and accurately.

Specifications:
The mirror and detector rotates around the luminaire under test with an angle of () vertical axis ±180 (or 0-360) and the luminaire rotates around itself with an angle of (C) horizontal axis ±180 (or 0-360 ).
The accuracy of angle: 0.05, Resolution of angle: 0.001
Accuracy of Goniophotometry detector: Constant temperature photo detector DIN5032-6/CIE pub1. No. 69 Class L
LISUN goniophotometer software can export CIE, IES, LDT and other format files. These kinds of format files can be used via other illumination and luminaire design software such as DiaLux.
Connect the goniophotometer to PC via USB cable. English version software can run on Win7, Win8 or Win10, Win11
LSG-6000 can be used together with a CCD Spectroradiometer to test spatial CCT Distribution and other Spectral color parameters. We call this system Goniospectroradiometer (LSG-6000CCD)â??. LSG-6000CCD Goniospectroradiometer = LSG-6000 Goniophotometer System + LPCE-2 Integrating sphere Spectroradiometer System. Please click to download the LSG-6000CCD Brochure
The LSG-6000CCD software and hardware support the plant lighting PAR, PPF and PPFD spatial distribution test , and it can export IES/LDT files

Price and Minimum Quantity

Price: $1
MOQ: Not Specified

Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Lm-79 Moving Detector Goniophotometer

Nov-10-23

Lm-79 Moving Detector Goniophotometer

$64.80K
MOQ: Not Specified
Supplier From Shanghai, , China
 
What is the definition of type C goniophotometer?
LSG-6000 Moving Detector Goniophotometer (Mirror Type C) was manufactured by LISUN completely meets LM-79-19, IES LM-80-08, COMMISSION DELEGATED REGULATION (EU) 2019/2015, CIE-121, CIE S025, SASO 2902, IS16106 and EN13032-1 clause 6.1.1.3 type 4 requirements. LSG-6000 is the latest upgraded product of LSG-5000 and LSG-3000 in compliance with the requirements of the LM-79-19 standard Clause 7.3.1, its an automatic light distribution intensity 3D curve testing system for measuring light. The darkroom can be designed according to the customerâ??s existing room size.

What is the use of goniophotometer?
LSG-6000 gonio photometer manufacturer is LISUN, it can measure all types of lighting sources, LED, Plant Lighting or HID luminaires such as indoor and outdoor luminaires, roadway luminaires, street lamps, flood lights and other kinds of luminaires.
May-14-21
 
LSG-6000 Moving Detector Goniophotometer Mirror Type C (updated version for LSG-5000/LSG-3000) is for LED measurement and completely meets LM-79-19 Clause 9.3.1 requirement. For candela intensity distribution, EEI, color temperature distribution and IES, LDT files measurement.
GOLD Member
Mar-28-23
 
Salisbury's Self-Testing Voltage Detectors allow testing to be continuous and automatic. An intermittent flash and beep confirms the detector is functioning properly. Self-Testing Voltage Detectors are used to verify live or de-energized conductors. These testers may be used with rubber insulating gloves or hot sticks using the splined universal end fitting. Testers indicate the presence of voltage with an extra bright LED light and a distinctive audible signal. It is recommended that the tester be moved closer to the conductor until a warning is indicated, or it touches the conductor, apparatus, or elbow test point. Each tester requires three C batteries (included).

Features & Benefits: Do not assume conductors that have been tested de-energized will stay de-energized. Always install proper grounding devices before working. Failure to do so may result in serious injury or death. Dimensions in. (mm): 11 x 3.5 ( 279.4 x 89 )
GOLD Member
Jun-08-24

Thiabendazole Cas 148-79-8

$30
MOQ: 1  Kilograms
Sample Available
 
As an antiparasitic, it is capable of treating roundworms, hookworms, and other kinds of helminth species that can attack wild animals, livestock and humans. It also has effects of inhibiting the angiogenesis of cells. The mechanism of action is still not fully understood. It has found that Thiabendazole is capable of suppressing the helminth-specific mitochondrial enzyme fumarate reductase, further inhibiting the citric acid cycle, mitochondrial respiration and ATP production, leading to helminth's death. It may also inhibit the microtubule polymerization processes.
GOLD Member
Apr-18-24

D-Pantothenic Acid Cas 79-83-4

$40
MOQ: 1  Kilograms
Sample Available
 
D-calcium pantothenate is a white powder, no smelly odor, tastes a little bitter, has hydroscopic property. Its aqueous solution shows neutrality or slightly alkaline, easy to dissolve in water, slightly solvable in ethanol, almost can not dissolve in chloroform or aether.
Item Index
Authentication Positive reaction
Calcium content ,(Ca) %(weight on dry product) 8.2-8.6
Nitrogen content ,(N)%(weight on dry product) 5.7-6.0
specific optical rotation, ([a]D20)%(weight on dry product) +25�°-+27.5�°
Heavy metal (count on Pb),% â?¤0.002
Loss on drying,% â?¤5.0
Uses:feed additive, food additive, pharmaceutical USP28/BP2003
Packing:25kg/Carton, 25kg/drum
Storage:store in cool,shady and dry place.
Period of validity:3 years, use it as quickly as possible after unseal
GOLD Member
Apr-24-24

Cas 12190-79-3 Cobalt Oxide

$2
MOQ: 1  Metric Tonnes
Sample Available
 
Basic information:

1.Molecular formula: Co3O4
2.Molecular weight: 240.797
3.CAS No.: 1308-06-1
4.Purity: Co:72%min
5.Storage: Keep the receptacle sealed and stored in a cool and dry place, and ensure that the working room has good ventilation or exhaust device.

Cobalt Tetroxide is similar to ferroferric oxide, and can be approximately regarded as a compound formed by cobalt oxide (CoO) and cobalt oxide (Co2O3). Black or grayish black powder. The apparent density is 0.5-1.5g/cm3, and the tap density is 2.0-3.0g/cm3. Cobalt Tetroxide can be slowly dissolved in hot sulfuric acid, but it is insoluble in water, n itric acid and h ydrochloric acid at room temperature. When heated above 1200 C, it will decompose into cobaltous oxide. When it is strongly heated to 900C in a hydrogen flame, it is reduced to metal cobalt.
GOLD Member
Mar-27-24

Glycolic Acid Cas 79-14-1

$15 - $20
MOQ: 1  Kilograms
Sample Available
 
Chemcial name: Glycolic acid

Another name: alpha-Hydroxyacetic acid

Standard: Technical grade
CAS NO.:79-14-1
EINECS: 201-180-5
Molecular Fomula: C2H4O3
Structural formula:

Molecular Weight: M=76.05
Assay:70%;99%
Application:Cosmetics Personal Care
Capacity:10000MT/Year
Sample: available


1. Cosmetics Personal Care

2. Hard Surface Cleaner

Glycolic Acid is the organic of choice for cleaning unmovable surfaces.

3. Industrial Water Boiler System Cleaners

Glycolic Acid removes hard water scale deposits by forming water soluble complexes which are easily rinsed away.

4. Laundry Sours

Glycolic Acid is the dependable, flexible liquid sour required by modern laundry systems.

5. Metal Cleaning Finishing

Glycolic Acid is highly effective for copper and aluminum finishing and metal cleaning applications.

6. Disinfecting Formulations Applications

Used for manufacturing active ingredient use in liquid disinfecting formulations
GOLD Member
VERIFIED
Oct-17-22
Supplier From Mumbai, Maharashtra, India
 
Solvent Yellow 62 Solvent Red 8
Solvent Yellow 82 Solvent Red 79
Solvent Yellow 90 Solvent Red 89
Solvent Orange 54 Solvent Red 119
Solvent Orange 58 Solvent Red 122
Solvent Orange 62 Solvent Red 127
Solvent Orange 99 Solvent Red 132
Solvent Blue 48 Solvent Red 160
Solvent Blue 67 Solvent Black 27
Solvent Blue 70 Solvent Black 29
Solvent Violet 8 Solvent Black 34
Solvent Brown 43
GOLD Member
VERIFIED
Oct-16-22

Acid Dyes

MOQ: Not Specified
Supplier From Mumbai, Maharashtra, India
 
Acid Black 1 Acid Red 119 Acid Orange 74
Acid Black 11 Acid Red 131 Acid Orange 80
Acid Black 24 Acid Red 151 Acid Orange 142
Acid Black 26 Acid Brown 14 Acid Violet 17
Acid Black 52 Acid Brown 75 Acid Violet 49
Acid Black 173 Acid Brown 79 Acid Violet 54
Acid Black 174 Acid Brown 106 Acid Blue 7
Acid Black 194 Acid Brown 158 Acid Blue 9
Acid Black 210 Acid Brown 214 Acid Blue 15
Acid Black 234 Acid Brown 348 Acid Blue 92
Acid Red 14 Acid Brown 349 Acid Blue 113
Acid Red 17 Acid Brown 355 Acid Blue Br
Acid Red 18 Acid Yellow 11 Acid Blue N
Acid Red 33 Acid Yellow 17 Acid Blue V
Acid Red 44 Acid Yellow 23 Acid Green 1
Acid Red 52 Acid Yellow 42 Acid Green 3
Acid Red 54 Acid Yellow 73(Uranine) Acid Green 9
Acid Red 73 Acid Yellow 99 Acid Green 16
Acid Red 87(Eosine Sodium) Acid Yellow 110 Acid Green 17
Acid Red 88 Acid Yellow 194 Acid Green 20
Acid Red 89 Acid Orange 3 Acid Green 25
Acid Red 97 Acid Orange 7(Acid Orange Ii) Acid Green 111
Acid Red 99 Acid Orange 10
Acid Red 114 Acid Orange 56

R/o Salt Free Dyes For Ink Application
Acid Red 52 Acid Blue 15 Acid Violet 17
Acid Red 87 Acid Blue 25 Acid Black 1
Acid Blue 9 Acid Yellow 151

Verification Status