PLD8000C Dynamic FPD Radiography and Fluoroscopy System
Features Benefits
Selfdeveloped ultrahigh frequency and high voltage generator
Good Xray source
Strong penetration ability
Lowdose radiation
Stable performance
Highquality image
High efficiency
Flexible flat panel detector
Standard highresolution dynamic flatpanel
Removable dual grid
Removable grid for reducing radiation
Designed for pediatrics
Highquality Xray tube
Large heat capacity
High rotate speed of Xray tube
Suitable for long time and highintensity work
Have long service life
High Performance and Intelligent
Easily ascending and descending
ascend or descend ina large range low ground clearance
convenient to move patients reduce patients pain
Table Rises and falls freely
Wide liting range
special angiographic examination
Lower dose to protect doctors and patients
Free column movement
Large Scale movement of detector
radiography of different body parts
Free stretching
SID can electrically strech to 18m
meet the needs of special clinical radiography
High Performance and Intelligent
Pulse fluoroscopy
Instant exposure reduce image noise and improve clarity
reduce the radiation dose
DAP Optional
Intelligent radiation dose monitoring
Care for the health of patients and doctors
Simultaneous monitoring with backend interconnection
Automatic stitching function Optional
Correction of panoramic photography
reliable diagnosis basis for clinic
AEC Optional
High level ionization chambrer
Intelligent control of exposure more efficient
Intelligent control of light sensitivity
Intelligent operation
Intelligent workstation with humanized design
Intelligent control intuitive display fficient and fast
The system can be maintained remotely it can perform fault selfdiagnosis and display the fault code quickly and accurately determine the fault status and has selfprotection function
lt can share information with PACS system bring benefits for remote diagnosis
PLX101 Series High Frequency Mobile X-ray Equipment PLX101/101A/101C Rocker safety lock design, make your operate much safer High quality x-ray monoblock assures more details, less dose Symmetrical adjustable collimator for accurate positioning and better exposure protection Aviation aluminum connectors, connection reliable, more safety Advanced dislocation braking system, flexible movement, flexible braking Multifunctional cassette storage box design Features Our high frequency technology assures the best image in every operating condition Along with reduced patient dose and extended x-ray tube life time The generator provide the right amount of penetration, reducing exposure times and retakes. The parameter can be adjusted by the kV and mAs. Multiple security protect function such as over-voltage, over-current. 50 preset exposure programs allow extensive possibilities to optimize the exposure and processing parameters according to your preferences. Fault automatic protection setting and fault alarming display Parameters are automatically storage when power cut off. Adopt rotating beam limiting device to adjust the X-ray field and angle freely. Adopt manual controller and remote controller to do exposure. Optional: PLXF152 mobile table for high frequency mobile X-ray equipment. PLX101D is equipped with built-in battery, can take 200 films when full charged. Rocker can move up and down, automatically balance High quality X-ray monoblock can rotate in ±90 Options PLXF152 Mobile Bed For Mobile X-ray Machine Size: 2000 X 700X 500mm Range of grid box movement 1210mm Size of grid box: 430X 430(17 X 17) Bucky Stand Height: 1770mm Vertical movement range: 470-1470mm Grid density: 103L/inch Grid radio: 10:1 Focus distance: 150cm Maximum grid box: 17 X 17 Technical Parameters
100 mA, 100 KVP Mobile X-ray Machine 100mA, 100 KVP, Mobile X-ray Machine for Radiography only Electronic Timer Electronic Overload Protection Device Stationary Anode X-ray Tube : BEL or Imported Collimator Counter Balanced Mobile Stand Suitable for Bed Side X-rays
Brand New Ge Make Portable 20 Ma X Ray Machine For Sale With Tube Head Anmd Console .(fully Refurbished Equipment)
We're a leading XRay machine and accessories manufacturer company with over 29 years of experience and global presence and distributor network in 7 different countries. We have Line Frequency & High Frequency, APR X-Ray Machine, Dental X-Ray Machine, Mobile 100MA X-Ray Machine, 300MA X-Ray Machine, 500MA XRay Machine, Vertical Bucky, Multi-Position Bucky Table, 4 & 2 Way Floating Bucky Table Etc Beside new machines, we offer complete modification & repairing of any brand XRay machines, Rotating Anode Tube Head, HT 100MA, 300MA, 500MA Etc
Power Output 5.0KW x ray machine Main Inverter frequency 40 KHz X-ray Tube of radiography machine fixed anode focus: 1.5 (X-ray tube for high frequency) Power Supply 220V�±10% 50Hz Inner-resistance â?¤1.0�© Operation Method Wire/wireless control mobile x-ray machine safety mobile x ray machine cost mobile x ray machine price
2.5kw high frequency portable X-ray machines PLX101 x ray tube Fixed Anode Power Output of x ray machine 2.5kW Frequency 25kHz Tube voltage 40~100kV Power Supply 220V�±10%, 50kHZ Operation Method Wire/ Wireless control price list of x-ray machine price of 500ma x-ray machine price of medical x ray machine
X-ray machine Technical parameter 1. The numbers of x-ray tubes used in the product are also used as product number and x-ray generator (bulb tube head) number. 2. The current and voltage of x-ray tubes are fixed in three groups, they are: X exposure voltageú¿kvpú¬ 60 65 70 X-ray currentú¿maú¬ 0.50 0.85 1.10 3. When adding up voltage, total current is less than 2a and total power is 500w 4. Drain current and earth resistance are in accordant with the stipulates in gb9706.1 5. The three groups of voltage (60kvíó65kvíó70kv) are adjustable. 6ú«wireless remote control in any angles within 10 meters part form the control box 7. The parameter of x-ray generator (bulb tube head) 7.1. The parameter of x-ray tubes A. Focus index: 0.3í-0.3mm2 Bú«the voltage of the-highest-voltage generator: 90kv C. The highest inverse peak voltage: 90kv D. Filament characteristic: vf=5ví+0.5vú¼if=3a E. Target surface obliquity: 12íp F. The cooling manner of bulb tube head: oil immersion 8.7.2 the parameter of x-ray generator (bulb tube head): A. Focus-skin distance: 200mm B. The thickness of filter-ray film: more than 1.5mmal C. The leakage rate of x-ray: no more than 0.002mgy/h (no. 29.204.3 in gb9706.12 prescript that the leakage rate of x-ray is no more than 0.25mgy/h) D. The manner of limiting beam: using planigraphic device
Technical parameter 1. The numbers of x-ray tubes used in the product are also used as product numbers and x-ray generator (bulb tube head) numbers. 2. The current and voltage of x-ray tubes are fixed in three groups, they are: X exposure voltage (kvp) 60 65 70 X-ray current (ma) 0.50 0.85 1.10 3. When adding up voltage, total current is less than 2a and total power is 500w 4. Drain current and earth resistance are in accordant with the stipulates in gb9706.1 5. The three groups of voltage (60kv, 65kv, 70kv) are adjustable. 6. Wireless remote control in any angles within 10 meters part form the control box 7. The parameter of x-ray generator (bulb tube head) 7.1. The parameter of x-ray tubes A. Focus index: 0.3í-0.3mm2 B. The voltage of the-highest-voltage generator: 90kv C. The highest inverse peak voltage: 90kv D. Filament characteristic: vf=5ví+0.5v, if=3a E. Target surface obliquity: 12íp F. The cooling manner of bulb tube head: oil immersion 7.2 the parameter of x-ray generator (bulb tube head): A. Focus-skin distance: 200mm B. The thickness of filter-ray film: more than 1.5mmal C. The leakage rate of x-ray: no more than 0.002mgy/h (no. 29.204.3 in gb9706.12 prescript that the leakage rate of x-ray is no more than 0.25mgy/h) D. The manner of limiting beam: using planigraphic device
100 mA Mobile x-ray machine. very good image quality. built in stabilizer. works on 220v AC.