mainly responsible for the purchasing of hydraulic pump components. Last October, developed a new hydraulic pump and planned to promote this new product at this year's exhibition. During the debugging, the output pressure of the hydraulic pump can not be established several times, which is a little troublesome, because the owner has sent all the invitations to the exhibition to the customers and grandly introduced the functions of this hydraulic pump. The R & D personnel checked and tested each component one by one. It is basically certain that it is caused by the instability of the pilot operated pressure control valve.
The technical team dissected the pilot pressure control valve and found local friction marks on one side of the hole wall of the valve body. The diagnosis conclusion is that the main valve spool is stuck, which should be caused by the concentricity difference between the hole of the main valve body and the hole of the pilot pressure control valve body. to re purchase the pilot pressure control valve that meets the technical requirements, which must be solved within 25 days, otherwise he will leave because the exhibition is too important. the original hydraulic valve manufacturer and got a reply that due to equipment, he could not produce high-precision pilot pressure control valves with the exactly same concentricity. At the same time, he contacted a number of hydraulic valve suppliers and they basically replied that they could not do such a high precision pilot operated pressure control valve, which made almost .
When searched the hydraulic valve suppliers in , he found AAK HYDRAULIC VALVE. The details page of the hydraulic valve on AAK made feel that maybe AAK could have a try. He emailed us firstly to ask whether the concentricity of the pilot operated pressure control valve could be consistent. We need the detailed drawings, working conditions and parameters of his whole hydraulic pump to judge. After receiving all information from him, AAK technical team pondered the whole afternoon, with more than 95 confidence, and it would take 15 20 days to complete it.
he was happy and uneasy. He was happy that some hydraulic valve manufacturer could try this high-precision pilot operated pressure control valve and has a high probability of success. He was uneasy that if AAK HYDRAULIC VALVE did not succeed in proofing, the time would be wasted. We understand his concern. We told him that the reason why we are not sure for 100 is that there is a data that can't be determined. If AAK HYDRAULIC VALVE failed in sampling, then he should not waste time in Ningbo area. We suggest that he also find a hydraulic valve supplier in Europe, so as to sample with AAK at the same time.
Carbon Steel Pilot Operated Pressure Reducing Valve Rating : Max. Inlet Pressure 350 PSIG (24.1 Bar) Set Pressure range 5/60, 20/50, 40/125 PSIG for Steam Material : Carbon Steel Description : Pilot Operated, R-Type Trim : SS410 + Stellite Ends : Flanged Specials : IBR Item Code : BM000030 Size : 15mm Notes : Available Valve Size : 25mm to 200mm
Erik compared more than 20 hydraulic pilot pressure control valve factories. No manufacturer can do the hydraulic pilot operated pressure control valves which can be used under high pressure above 450bar for more than one year. AAK hydraulic pilot operated pressure control valve passes the test at one time, and there is no abnormality after one year of use. Erik is from a German hydraulic equipment manufacturer. In the first half of last year, the company needed to purchase a special hydraulic pilot operated pressure control valve with a working pressure of more than 450 bar, a service life of more than one year and a durability of more than 2 million times. The boss realized that it was some difficult to purchase the hydraulic pilot operated pressure control valve this time, and asked Erik and his colleague to purchase at the same time. Whoever successfully purchased the hydraulic pilot operated pressure control valve first will be promoted and raised. Erik is full of energy and keeps looking for hydraulic pilot operated pressure control valve factories online and offline. He contacted more than 20 new suppliers, including AAK hydraulic valve. Most of the hydraulic pilot operated pressure control valve manufacturers replied that they need to be customized from the beginning of materials, and it takes 25 days to sample this special hydraulic pilot operated pressure control valve. Erik chose two factories to test the samples. A month later, Erik received the samples and asked the engineer to test them. The results failed, but the hydraulic pilot operated pressure control valve obtained by his colleague passed the first test, which made Erik very depressed. Fortunately, this is just in the test stage, the final effect depends on the test results of the hydraulic pilot operated pressure control valve one year later. Erik contacted AAK for the second time. He clearly informed that the samples of hydraulic pilot operated pressure control valves he selected in the first round failed. For the first time, he did not choose AAK because AAK needed 35 days. This time, he only asked AAK to make samples. Whether he can win or not, he can only count on AAK. Because the material selection and internal test of hydraulic pilot operated pressure control valves need time, Erik also understands the difficulties of making the samples. After 35 days, AAK sent 6 samples of hydraulic pilot operated pressure control valves. Last week, almost a year after the hydraulic pilot operated pressure control valve samples were sent, Erik sent an email to inform that AAK hydraulic pilot operated pressure control valve was the only sample that passed 2 million tests, and there was no abnormality after one year of use. Although his colleague's sample passed the early test, it could not withstand the high pressure above 450 bar for enough time, it leaked in less than a year.
For the leakage in the pilot-operated pressure control valves less than 2drops /min, Howard from Accupress in Canada, contacted more than 30 Chinese hydraulic valve manufacturers. Only AAK pilot-operated pressure control valves met the standard and replaced his local factory in the United States. Last year, the hydraulic shearing machine they listed sold well. The boss decided to mass produce it in Suzhou, China. However, the pilot-operated pressure control valve to be used in the hydraulic shearing machine was originally purchased in the United States, and the internal leakage is less than 2drops / min. If the pilot-operated pressure control valve is purchased from China, it will save money and time. While contacting some old suppliers, Howard is also looking for new manufacturers of pilot-operated pressure control valves. We also received Howard's inquiry. The email subject is: can you supply pilot-operated pressure control valves with internal leakage less than 2drops / min for our Suzhou factory? We thought it was a domestic purchase, so we politely refused. Until Howard's second email told us why he wanted to ship to Suzhou, and he contacted more than 30 Chinese hydraulic valve manufacturers, only two of them replied that they could try to make samples of pilot-operated pressure control valves with internal leakage less than 2drops/min, and there was no any reply from the other manufacturers. Howard asked if AAK pilot-operated pressure control valves could meet American factory standards? If not, the sample is meaningless. I told him directly that AAK had tested samples of pilot-operated pressure control valves with internal leakage less than 2drops/min for a German company some time ago. The pilot-operated pressure control valves can be refunded in full if our samples do not meet the standard. One month later, 30 pilot operated pressure control valves were sent to Accupress's Suzhou plant. Four weeks later, Howard sent an email saying that their engineers tested the pilot operated pressure control valves of AAK and two other manufacturers, and only AAK samples met the standard. Some parameters were higher than those of the original American factory, and those of the other two manufacturers did not meet the standards. In particular, AAK pilot operated pressure control valves caught up with and surpassed his American factory, which surprised him. AAK pilot operated pressure control valves can meet such requirements because of two reasons: 1ã??For the pilot operated pressure control valves, the matching clearance accuracy between the valve spool and the valve body directly determines the internal leakage of the whole valve. AAK has German Nagel precision honing machine. After honing, the dimensional accuracy of the cone plating of the valve spool and valve body of the pilot operated pressure control valve is IT7 ~ 4, and the surface roughness can reach Ra0.32 ~ 0.04�¼m, which can not be achieved by most of hydraulic valve
Lucas is from a Canadian hydraulic equipment company. He found AAK hydraulic valves online last September. His first inquiry was the hydraulic pilot-operated pressure control valve. After 3 rounds of email communication, he placed a trial order for 20 pcs of hydraulic pilot-operated pressure control valves. I received the order so smoothly, but I didn't expect that AAK would almost take the blame for others in the first cooperation. At the beginning of last month, Lucas informed by email that there were problems with all 20 hydraulic pilot-operated pressure control valves provided by AAK. When the equipment was installed and debugged, the hydraulic system went on strike. This is the first time I have encountered such a complaint. AAK will do various tests on each hydraulic pilot-operated pressure control valve before leaving the factory, and deliver it only after it is qualified. I asked the engineer and the workshop to verify. It was proved that the programming and production of the hydraulic pilot-operated pressure control valves are completely consistent with the drawings provided by Lucas, so I can ensure that the samples of AAK hydraulic pilot-operated pressure control valves are qualified. Our engineers speculate that there may be a problem with the oil circuit design of the valve block system, but Lucas engineers believe that AAK is shirking the responsibility. So I suggest Lucas try the hydraulic pilot-operated pressure control valves of other manufacturers to debug. If the hydraulic system is still abnormal, our guess is right. Two weeks later, Lucas frankly told us that there should be a problem with the oil circuit design and asked us what good methods we had? The next day, Lucas sent us the video of equipment commissioning. Indeed, during the operation of the equipment, the speed increases when the cylinder of the hydraulic system is lowered, which is equivalent to the increase of flow, and the original set pressure of the hydraulic pilot-operated pressure control valve will also increase, resulting in the instability of system pressure. Therefore, it is inferred that the instability of pressure is caused by the thin oil passage of the hydraulic valve block in the system. We suggest that he send us the schematic diagram of the hydraulic system. After analysis, AAK engineers believe that the oil circuit design cannot match the working conditions of the equipment. AAK plans to design and process a new hydraulic valve block, and then installs the AAK hydraulic pilot-operated pressure control valves to debug the equipment. If it is not successful, AAK will not charge any fee for the hydraulic valve block. A month later, AAK sent out the newly designed hydraulic valve block. Lucas sent an email 3 days after receiving AAK hydraulic valve block. He informed that after installing the AAK designed hydraulic valve block and the hydraulic pilot-operated pressure control valves, the hydra
William is a purchaser of a hydraulic equipment company in the United States. At the beginning of last year, a South American customer wanted to customize a drilling machine for geological exploration. The South American customer promised to order this equipment for a long time if it has excellent performance and stability. The owner asked the engineers to design and test samples. According to the working conditions, the maximum pressure of the hydraulic system is 450bar or above, which has a very high requirement on the pressure resistance and stability of the hydraulic pilot operated pressure control valves. When William received the task of purchasing this hydraulic pilot operated pressure control valve, he felt a big pressure, because the pressure resistance of normal hydraulic pilot operated pressure control valve is basically 250bar, and the maximum pressure resistance provided by previous hydraulic valve manufacturers was also only 380bar. He asked all the hydraulic valve manufacturers that he contacted before, they basically replied that according to this working condition, their hydraulic pilot operated pressure control valve can only ensure a service life of 3 months, but the customer asked for a service life of 1 year. William also contacted the local hydraulic valve manufacturers in the United States. They told him that he could not promise a service life of 1 year for this hydraulic pilot operated pressure control valve. They can only test the samples first, then to know the service life. One of his other hydraulic valve manufacturers in China introduced AAK to him. He told William that AAK shipped a hydraulic pilot operated pressure control valve for a working condition of maximum pressure 450bar before, but the service life required by that customer is 6 months. After receiving the drawings of the hydraulic pilot operated pressure control valve from William, AAK technical team found that the requirements of this hydraulic pilot operated pressure control valve were higher than those of our last shipment. The conventional No. 45 steel could not meet the requirements, so we had to find special steel. Later, after 5 times of material selection and testing, 2 months later, AAK internal sample testing was successful by using a German steel with high wear resistance and high fatigue resistance. After sending the samples of hydraulic pilot operated pressure control valve, we have been waiting for news from William. William said that no news from customer is the best news. Last month, 1 year after AAK samples were sent, William emailed us that he would order 100 hydraulic pilot operated pressure control valves at one time. The quality standard is the same as that of the hydraulic pilot operated pressure control valves sent last year. Because the other hydraulic valve manufacturers in China can only ensure the service life of 3 months,
Pressure rating: 1.6- 2.5mpa Specification : dn15-50 Material:steel wcb Standard flanges :din ansi jis jb79. This reducing valve is the new type pilot extra-huge membrane pressure reducing valve developed by our company. It is greatly improved on basis of normal pressure reducing valve. The membrane use new material, enlarging the working area, so the slight change of upper pressure or lower pressure can be fed back to membrane of main valve, and adjust the opening of main valve to ensure the constant pressure of lower stream pressure. Plywood case
Supplier: 1 ) pp woven bags 2 ) pp woven fabric & pp woven rolls 3) bopp woven sack 4) fibc bag / jumbo bag 5 ) block bottom valve bag 6 ) block bottom bag with open mouth 7 ) jute bag 8 ) wheat flour 9 ) wheat flour maida 10 ) organic wheat flour 11) wheat flour type 55 to 65 12) ashirwad wheat flour