ALSTOM GBCDG31FF014SBCH
NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E
Model No - CDG31FF014SBCH
RELAY TYPE - CDG 31
APPLICATION - 2 O/C + 1 E/F
BURDEN / D.M.T - 3 VA / 1.3 SEC.
C.T. SECONDARY - 1 AMP CT.
CASE SIZE - 3D VERT.
CONTACTS (S/R OR H/R) - 2 N/O S/R
E/F SETTING - 0.1 - 0.4 Amps.
FLAG - YES
FREQUENCY - 50 HZ
MOUNTING - FLUSH
O/C SETTING - 0.5 - 2 Amps.
NAME PLATE - RFG9125 901
Outline Diagram MFJ013
Wiring Diagram MFDZ801-101-1
GBCDG31EG001SACH NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E Model No : CDG31EG001SA(M) CDG31 APPLICATION - 3 O/C BURDEN / D.M.T - 3 VA / 3 SEC. C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 3D HORZ. CONTACTS (S/R OR H/R) - 2 N/O S/R FLAG - YES FREQUENCY - 50 HZ MOUNTING - FLUSH O/C SETTING - 2.5 - 10 Amps. Name Plate RFG9126774 Outline Diagram MFJ014 Wiring Diagram MADZ802.63-1
GBCDG31EG001SBCH NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E Technical Specifications Model No - CDG31EG001SBCH RELAY TYPE - CDG 31 APPLICATION - 2 O/C + 1 E/F BURDEN / D.M.T - 3 VA / 3 SECS. C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 3D HORZ. CONTACTS (S/R OR H/R) - 2 N/O S/R E/F SETTING - 1 - 4 Amps. FLAG - YES FREQUENCY - 50 HZ MOUNTING - FLUSH O/C SETTING - 2.5 - 10 Amps. NAME PLATE - RFG9126 904 Outline Diagram MFJ 014 Wiring Diagram MADZ802.63-1
GBCDG31EG001SCCH NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E Model No : CDG31EG001SC(M) CDG31 APPLICATION - 3 O/C BURDEN / D.M.T - 3 VA /3 SEC. C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 3D HORZ. CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R FLAG - YES FREQUENCY - 50 HZ MOUNTING - FLUSH O/C SETTING - 2.5 - 10 Amps. Name Plate RFG9126674 Outline Diagram MFJ014 Wiring Diagram MADZ802.64-1
GBCDG31EG001SDCH NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E Model No - CDG31EG001SD(M) RELAY TYPE - CDG 31 APPLICATION - 2 O/C + 1 E/F BURDEN / D.M.T - 3 VA / 3 SEC. C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 3D HORZ. CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R E/F SETTING - 1 - 4 Amps. FLAG - YES FREQUENCY - 50 HZ MOUNTING - FLUSH O/C SETTING - 2.5 - 10 Amps. Name Plate - RFG9126 904 Outline Diagram MFJ 014 Wiring Diagram MADZ802.64-1
GBCDG31EG002SACH NON DIR.SELF POWER 3 O/C RELAY 2M S/R TECHNICAL SPECIFICATION Model No : CDG31EG002SACH CDG31 APPLICATION - 3 O/C BURDEN / D.M.T - 3 VA / 3 SEC. C.T. SECONDARY - 1 AMP CT. CASE SIZE - 3D HORZ. CONTACTS (S/R OR H/R) - 2 N/O S/R FLAG - YES FREQUENCY - 50 HZ MOUNTING - FLUSH O/C OR O/V SETTING - 0.5 - 2 Amps. Name Plate RFG9126771 Outline Diagram MFJ014 Wiring Diagram MADZ802-63-1
GBCDG31EG002SBCH NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E MODEL NO - CDG31EG002SBCH RELAY TYPE - CDG 31 APPLICATION - 2 O/C + 1 E/F BURDEN / D.M.T - 3 VA / 3 SEC. C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 3D HORZ. CONTACTS (S/R OR H/R) - 2 N/O S/R E/F SETTING - 0.5 - 2 Amps. FLAG - YES FREQUENCY - 50 HZ MOUNTING - FLUSH O/C SETTING - 2.5 - 10 Amps. NAME PLATE - RFG9126 903 Outline Diagram MFJ 014 Wiring Diagram MADZ802.63-1
GBCDG31EG002SCCH NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E Technical specification Relay Model No CDG31EG002SC(M) Relay type CDG31 CASE SIZE 3D HORZ. APPLICATION 3 O/C O/C SETTING 0.5 - 2 Amps BURDEN / D.M.T 3 VA / 3 SEC. Taps Std C.T. SECONDARY 1 AMP CT. CONTACTS (S/R OR H/R) 2 N/O 2 N/C H/R FLAG YES FREQUENCY 50 HZ MOUNTING FLUSH Name Plate RFG9126 671 Outline Diagram MFJ 014 Wiring Diagram MADZ802.64-1
GBCDG31EG002SDCH NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E Technical Specifications Relay model No CDG31EG002SDCH Relay type CDG 31 Case size 3D H 30T Application 2 O/C + 1 E/F Current setting - O/C 2.5 to 10 amps ( 50-200% ) Contacts (S/R OR H/R) 2 N/O 2 N/C H/R Output Contacts 2 N/O 2 N/C H/R Taps / Burden Std / 3 VA C.T.Secondary 5 amps D.M.T 3 secs Current setting - E/F 0.5 to 2 amps (10 - 40% ) Flag / Mounting Yes / Flush Frequency 50 Hz Name plate RFG9126 903 Outline Diagram MFJ 014 Wiring Diagram MADZ 802.64-1
GBCDG31EG003SACH NON DIR.SELF POWER 3 O/C RELAY 2M S/R Technical specification Relay Model No CDG31EG003SACH Relay type CDG 31 Case size 3D Hor. Application 3 O/C Current setting 0.2 to 0.8 amps Contacts (S/R OR H/R) 3 N/O S/R Output contacts 2 N/O S/R Burden / Operating Time 3 VA / 3 Secs. C.T.Secondary 1 amps Taps / frequency Std / 50 Hz. Note:-write in name plate as over current instead of E/F. And Erase E/F symbol. Flag Yes Mounting Flush Name Plate RFG9126 793 Outline Diagram MFJ 014 Wiring Diagram MADZ802.63-1
GBCDG31EG003SBCH NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E Model No - CDG31EG003SB(M) RELAY TYPE - CDG 31 APPLICATION - 2 O/C + 1 E/F BURDEN / D.M.T - 3 VA / 3 SEC. C.T. SECONDARY - 1 AMP CT. CASE SIZE - 3D HORZ. CONTACTS (S/R OR H/R) - 2 N/O S/R E/F SETTING - 0.2 - 0.8 Amps. FLAG - YES FREQUENCY - 50 HZ MOUNTING - FLUSH O/C SETTING - 0.5 - 2 Amps. NAME PLATE - RFG9126 902 Outline Diagram MFJ014 Wiring Diagram MADZ802.63-1