3 1/2 / 114 mm strainer waste kit with basket strainer without overflow HIGH RANGE
ASK FOR OFFER
Italy
"Flange and basket grid : Stainless Steel
Finishing : Polished
Application : suitable for 1 bowl-sinks without overflow outlet
Plastic parts colour / materials :
grey or white / polypropylene
Place of Origin : Italy
Port Of Loading : any italian port
Payment Term : in advance
Delivery Time Shipment within 4 weeks from order confirmation"
"Unit Packing : bags
(neutral packaging with instruction and warning printed on bag)
Box qty : 80 pcs (carton box)
Pallet qty : 1280 pcs (fumigated pallets)
Minimum Order Quantity : 20 feet container
ask information for different quantities"
Product Name - SERIE 6400 FUTURO Product Description - " 1-bowl-siphon 40 mm Futuro U type permit to save space under the sink Price of product ( USD price or FOB price) - ASK FOR OFFER Product origin - Italy Key Specifications/Special Features - Application : Suitable for 1-bowl-sink decentrated wall outlet permitting to save space under the sink Plastic Colour / materials : grey or white / polypropylene Place of Origin : Italy Port Of Loading : any italian port Payment Term : in advance Delivery Time Shipment within 4 weeks from order confirmation" Minimum Order Size and Packaging details - Unit Packing : bags (neutral packaging with instruction and warning printed on bag) Box qty : 55 pcs (carton box) Pallet qty : 440 pcs (fumigated pallets) Minimum Order Quantity : 20 feet container ask information for different quantities"
SYSTEM INFORMATION The electromagnetic flow meter HMF 2110 series is the most common and highly accurate flow measurement device that can be universally used in various measurement fields. Since there is no driving part like a propeller, no trouble is caused due to pressure loss, and the durability is excellent In addition, since the installation is simple with the flange type, even a beginner can easily install it through simple training. The sensor measures the flow rate by direct contact with the fluid,, thus a more reliable flow rate value can be obtained, and the reproducibility is also excellent If you are looking for a flowmeter that can be used with confidence, choose the HMF 2110 series without hesitation. â?? KEY FEATURES Quick Start Self diagnostic Easy Maintenance â?? CHARACTERISTICS â?¢ Due to high stability, popular for water flow measurement â?¢ Excellent durability due to no driving part â?¢ Electrode and lining materials are selected for measuring chemical flow â?¢ There is no pressure drop, which reduces electricity costs. â?? SPECIFICATIONS * Sensor installation method : Flange mounting type (Standard: JIS, DIN, ANSI, etc.) * Accuracy : �±0.2% (flow rate 0.1 m/s or more)0.2% (flow rate 0.1 m/s or more) * Max Minimum Flow : 0.05 m/s ~ 10 m/s (Flow rate by diameter) * Measuring pipe caliber : 6 mm ~ 2,000 mm * Measurable fluid : Water, sewage, wastewater, chemicals, etc. (Conductivity of 5�¼S /cm or more) * Power : 110 ~ 220 V AC / 60 Hz * Operating temperature : Sensor (40 ~ 70 â??), Operation: (18 ~ 60 â??) * Screen display contents : LCD Size: LCD Display 100 x 55, 3 Line, 16 Characters, Instantaneous flow rate (4 digit), accumulated flow rate (9 digit), pressure (4 digit) * Flow display unit : Unit: m3, L, etc. / Directions: Forward & Reverse (-) * Electrode : Hastelloy C * Liner: NBR, Hard Rubber, EPDM * Flange : Carbon Steel * Flow measurement frequency : 1.875 ~ 12.5 Hz * Sensor cable length : 100m * Output signal : 4 ~ 20 mA, Integrated pulse active , Passive (Max 10 kHz), Relay pulse (Max Load 24 V DC / 1A) * Communication and memory : RS 232, RS 485 Modbus 128 Mbyte internal memory: date, time, instantaneous flow rate, accumulated flow rate, Pressure memory interval: 5 seconds ~ 24 hours * Protection class : Sensor unit: IP 68 / Operation unit: IP 65 * Self diagnosis function : Alarm display when empty pipe information and self diagnosis error occur For more details on quality Korean flowmeters, please feel free to visit http://www.hnl-global.com/flowmeter and contact us.
System Information The electromagnetic flow meter HMF 2110 series is the most common and highly accurate flow measurement device that can be universally used in various measurement fields. Since there is no driving part like a propeller, no trouble is caused due to pressure loss, and the durability is excellent In addition, since the installation is simple with the flange type, even a beginner can easily install it through simple training. The sensor measures the flow rate by direct contact with the fluid,, thus a more reliable flow rate value can be obtained, and the reproducibility is also excellent If you are looking for a flowmeter that can be used with confidence, choose the HMF 2110 series without hesitation. â?? KEY FEATURES Quick Start Self diagnostic Easy Maintenance â?? CHARACTERISTICS â?¢ Due to high stability, popular for water flow measurement â?¢ Excellent durability due to no driving part â?¢ Electrode and lining materials are selected for measuring chemical flow â?¢ There is no pressure drop, which reduces electricity costs. â?? SPECIFICATIONS * Sensor installation method : Flange mounting type (Standard: JIS, DIN, ANSI, etc.) * Accuracy : �±0.2% (flow rate 0.1 m/s or more)0.2% (flow rate 0.1 m/s or more) * Max Minimum Flow : 0.05 m/s ~ 10 m/s (Flow rate by diameter) * Measuring pipe caliber : 6 mm ~ 2,000 mm * Measurable fluid : Water, sewage, wastewater, chemicals, etc. (Conductivity of 5�¼S /cm or more) * Power : 110 ~ 220 V AC / 60 Hz * Operating temperature : Sensor (40 ~ 70 â??), Operation: (18 ~ 60 â??) * Screen display contents : LCD Size: LCD Display 100 x 55, 3 Line, 16 Characters, Instantaneous flow rate (4 digit), accumulated flow rate (9 digit), pressure (4 digit) * Flow display unit : Unit: m3, L, etc. / Directions: Forward & Reverse (-) * Electrode : Hastelloy C * Liner: NBR, Hard Rubber, EPDM * Flange : Carbon Steel * Flow measurement frequency : 1.875 ~ 12.5 Hz * Sensor cable length : 100m * Output signal : 4 ~ 20 mA, Integrated pulse active , Passive (Max 10 kHz), Relay pulse (Max Load 24 V DC / 1A) * Communication and memory : RS 232, RS 485 Modbus 128 Mbyte internal memory: date, time, instantaneous flow rate, accumulated flow rate, Pressure memory interval: 5 seconds ~ 24 hours * Protection class : Sensor unit: IP 68 / Operation unit: IP 65 * Self diagnosis function : Alarm display when empty pipe information and self diagnosis error occur For more details on quality Korean flowmeters, please feel free to visit http://www.hnl-global.com/flowmeter and contact us.
0.6MPA FRP TANKS (30 to 63 INCH) FOR INDUSTRIAL USE FRP Water Softening, Filter Tanks-Economy 100PSI-Rohone&Aowy Series FOR INDUSTRIAL: 30" to 63" FRP Water Softening, Filter Tanks-Economy 100PSI-Rohone&Aowy Series FOR INDUSTRIAL: 30" to 63" HEBEI CHENGDA HUAMO(HBCDHM in short) manufactures FRP tanks with design pressure 1.0Mpa(150Psi), 0.6Mpa(approx 100Psi) to meet various needs of the users. Structure and Materials of FRP Tanks Liner material: Rotation molding or Blowing One-piece seamless PE liner Outer Winding: High performance Epoxy resin + Fiberglass three-dimensional winding reinforcement. Opening: 2.5" and 4" reinforced plastic thread; 6" alloy flange. Base Materials: FRP or reinforced PP ASME Certification frp tanks Application Conditions Working Pressure: 150 psi(10.5 bar) for Winder series 0.6Mpa for Rohone and Aowy economy series. Working Temperature: 1 C - 49 C (34F - 120F) Max. Vacuum: 127mmHg Lowest Environment Temperature:-27 C (-17F) Strict Quality Control(Q/A) Fatigue test: 250, 000 times. (standard 100, 000 times) Burst test: 4 times of its design pressure. Certification: NSF & ACS, ASME Model: 0517-8079. Rohone and Aowy FRP tank also is Chengda brand: 100 Psi. (Chengda is the FRP RO membrane housing and FRP tanks production base for Frotec - the largest water treatment trading company in China. AOWY brand only for Frotec.) Specification of frp tanks No. Model Nominal dimension Opening Volume Base Dimension Top Bottom litre Gallon A (mm) B (mm) C (mm) D (mm) 1 06�?17 150*450 2.5"-8NPSM / 6.7 1.8 Standard 437 161 / 55 2 0635 150*890 2.5"-8NPSM / 15 4.0 Standard 896 61 / 155 3 0713 180*330 2.5"-8NPSM / 6.3 1.7 Standard 335 188 / 180 4 0717 180*432 2.5"-8NPSM / 8.6 2.3 Standard 437 188 / 180 8 0735 180*890 2.5"-8NPSM / 20.1 5.3 Standard 895 �¦188 / 180 9 07�?44 180*1110 2.5"-8NPSM / 24.5 6.5 Standard 1125 188 / 180 10 0813 200*330 2.5"-8NPSM / 8.5 2.2 Standard 335 216 / 207 FEATURE Chengda Winder, Rohone, and Aowy FRP softner tanks quality assurance: burst test with 4 times of its design pressure, and 250000 times cycle test. 1.HBCDHM FRP tanks (844-1665) use 600 TEX fiberglass, not 1200TEX fiberglass, with higher safety factor. 2.The base of HBCDHM FRP tank is made from pure raw material not recycled material, With better appearance, stronger toughness, and more environmentally friendly. 3.Key additives are imported from the US. APPLICATION HBCDHM FRP tanks are widely l used for water softening equipment in food processing plants, hospitals, laundries, manufacturing plants, office campuses and restaurants, condominiums, boiler feedwater, car washes, institutions, municipal, multimedia filters, carbon filters, iron filters, calcite filters and specialty media filters
Supplier: Polyamide flexible conduit & gland, ss cable ties, pa 66 cable ties, air vent ( fan filter ), air vent premium series, air vent oval design with epdm gasketing, a.b.s fan finger guard, metal fan finger guard, p.s junction box 1p 65, a.b.s junction box ip 55/65, a b s junction box ip 67, camera box, push button station, self adhesive gasket tape, toggle switches, l t control switches, p.a handles, document holder