Please click here to check who's online and chat with them.

Microprocessor Turbidity-Temp. Meter

Supplier From India
Apr-16-25

Microprocessor Turbidity-Temp. Meter S-966

Highly Stable & Accurate.
16 Character X 2 Lines Alphanumeric LCD.
30 mm flat bottom Test Tube.
0 to 1000 NTU
Automatic Range Selection.
Higher durability and long life.
Tested on quality parameters.
1000 Samples Storage with Date &Time.
Measurement of Temp. and Turbidity.

Technical Specifications:-

Model
S- 966

Turbidity
Range
0-1000 NTU
Resolution
1.0 NTU in lowest Range
Range Selection
Automatic
Accuracy
+3%, FS+1 -digit

Detector
Photodiode

Sample System
30mm Clear Glass Test Tube

Light Source
3.6 V/ 100ma LED

Calibration
Manual

Temperature

Range
0C to +100C

Resolution
0.1c

Accuracy
+0.2%

Input Type
Pt 100

Calibration
Auto/Manual

Display
16 Character X 2 Lines Alphanumeric LCD

Display Format
Temp &Turbidity Simultaneously

Setting
By Soft Touch Keys

Storage
1000 Samples With Date & Time

PC Interface
RS-232

Real Time Display
24 Hour Mode With Date

Power Supply
230 V +-10% Ac 50 Hz Dimension 198x238x103mm

Weight
3 kg.
Accessories-

Test tube (Set of 5)
Operation Manual
Dust Cover

Price and Minimum Quantity

Price: Negotiable
MOQ: Not Specified

Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Microprocessor Turbidity-Temp. Meter

GOLD Member
Apr-16-25
 
Portable Turbidity meter, has Principle Nephelometric Method (90)
2 to 5 points calibration, using formazin standards.
Selectable of 4 Turbidity units NTU, FNU, EBC, ASBC.
Single measurement mode, automatically identify and lock the measurement end.
Continuous measurement mode for indexing or matching vials.
Automatic Power OFF, effectively save battery energy consumption
Settings menu to customize the number of calibration points, date and time, display resolution etc...
Reset function, automatically restore the meter to factory default settings.
Expand memory to store or retrieve up to 100 sets of data.
USB communication interface, easy to transfer data or connect power adapter to the meter.
Automatic shutdown - After 15 minutes, If not in use
Carrying Case is Standard Supply

Principle-  Nephelometric Method (90)
Turbidity Measuring range-0~1100 NTU/0~275 EBC/0~9999 ASBC
Display resolution -0.01 (0~99 NTU), 0.1 (100~999 NTU), 1 (1000~1100 NTU)
Measurement accuracy -2% (0~500 NTU),+3% (501~1100 NTU)
Calibration point -  2 to 5 points (0.02, 10, 200, 500, 1000NTU)
Calibration Standard value : 200, 500, 1000 NTU
4 turbidity units-  NTU, FNU, EBC and ASBC.
Light source-  Infrared light-emitting diode, 850nm
Detector : Silicon photoelectric
Stray light : ; 0.02 NTU
Vial size -  60 (height) 25 (diameter) mm
Sample Volume : (approx.) 30ml
Carrying Case- Available
Auto-Power OFF : Yes
Display -  LCD
Data storage : 100 data readings
Ambient Temperature -  10 C~ 40 C
Interface- USB
Power supply type - AA battery 3 cells or DC5V power adapter
Packing Dimension -  (LxWxH) 280 x 80 x250 mm
Net / Gross Weight : 300g / 1.5kg
GOLD Member
Apr-16-25
 
Turbidity meter LMTB200 with TSS measurements mode,selectable four turbidity units
Turbidity meter is equipped with a 4.5" TFT display
2 to 7 points calibration using the formazin standards
Selectable four turbidity units,including the NTU,FNU,EBC and ASBC
TSS conversion factor ensures accurate measurement for total suspended solids
Contiuous measurement mode that can used for indexing and matching the sample vials
Hold fuction freezes current reading for easy viewing and recording
Password protection prevents the unathorised calibration and settings
Help message as a operational guide that helps user quickly begin using the meter
System menu allows setting the 9 parameters,including the date and time,resolution etc..,
Reset feature automatically resumes all settings back to factory default settings
GOLD Member
Apr-16-25
 
Highly Stable & Accurate
16X2 Line Alphanumeric LCD
1000 Samples Storage Facility
PC Interface Facility
Auto/Manual Calibration
D.O. & Temperature Measurements
Soft Touch Membrane Type Keys

Technical Specifications:-

Model
S- 955


Display
16X2 Line Alphanumeric LCD With Backlit


Range
DO: 0-20 ppm, Temp. 0-100C


Resolution
DO: 0.1 ppm, Temp.: 0.1C

Accuracy
DO: +0.2 ppm, Temp.: + 0.2C

Temp. Comp.
0-50C (Auto/Manual)

Key Board
8 Keys, Soft Touch Membrane Type

PC Interface
RS 232

Storage
Up to 1000 Samples

Power Supply
230V, + 10% AC, 50 Hz

Dimension
195X225X65 mm (LXBXH)

Weight
2 KG

 Accessories:

D.O. Probe
Temperature Probe.
D.O. Membranes
12V DC Adapter
Operation Manual
Dust Cover
RS 232
Software CD
GOLD Member
Apr-16-25
 
Microprocessor Nephelo Turbidity Meter S-968 is

Highly Stable & Accurate
4 Digit 7 Segment LED
30 mm Flat Bottom Test Tube
0 to 400 NTU
Higher Durability and Long Life
Tested on Quality Parameter

Technical Specifications-

Model
S- 968

Range
0-400 NTU (in 5 Ranges), 0-2, 10, 100, 200, 400

Resolution
1 NTU

Accuracy
+/- 3% FS, +1 Digit

Display
4 Digit 7 Segment LED

Light Source
3 V, 0.3 Amp LED Lamp

Detector
Photodiode

Sample System
30 mm Clear Glass Test Tube

Power Supply
230V, +-10% AC, 50 Hz

Dimension
195X230X95 mm (LXBXH)

Weight
3 KG

Accessories:-

Test Tube Set of 3
Operation Manual
Dust Cover
Mar-03-22
 
Turbidity Meters
GOLD Member
Mar-06-25
 
We are ready to supply "Lab Refrigerator".
KEY FEATURES:
Capacityof100 Liters to 1000 Liters.
Microprocessor controlled temperature control.
Non CFC compressor.
Interior illumination for working area.
Specially designed Stainless Steel trays.
Outer glass door(optional)
Available in GMP and Standard variants.

TEMPERATURE SPECIFICATION:
Temperature range - 2 C to 8C
Uniformity- ±1.0C
Temperature accuracy- ±0.5C

TEMPERATURE CONTROL:
Operating temp. 2C to 8C.
Motor and blower arrangement to have uniformity of temperature in loaded condition.
Inside See -through unbreakable acrylic door to
prevent loss oftemperature.
GOLD Member
Dec-19-24
 
Water testing equipment includes devices like pH meters, turbidity meters, and water quality testers. These tools are used to measure various parameters such as pH, turbidity, and chemical contaminants, ensuring water safety and compliance with environmental standards.
VERIFIED
Mar-07-14
Supplier From Guangzhou, Guangdong, China
GOLD Member
Nov-28-24
 
Forced convection digitally controlled hot air ovens suitable for precise heating drying and various other laboratory drying applications requiring controlled heating zone

Features
Forced convection system ensures good mixing strong dispersion and maintains higher temperature uniformity inside the chamber
Most ideal for various experiments in microbiology cell cultivation of animals and plants and food for various laboratories industries R D labs etc
Synthetic door gasket made of neoprene on the doublewalled door
Useroriented design of shelves makes you adjust each space of shelves without difficulty
Adjustable two ventilation slides control inner airvapor circulation
Beaded heating elements are placed in ribs at bottom and sides for uniform heat distribution

Constructional Features
Outer body made of CRC Sheet duly powder coated
Inner chamber and adjustable trays are made of Stainless Steel SS304 grade
Gap between the inner chamber and the outer wall is filled with highgrade mineral wool for minimal heat dissipation
Bigger sized units mounted on caster wheels for easy portability
Door fitted with heavyduty hinges and door handle ensuring there are no leakages through the door gasket
Temperature Range 50C to 250C
Temperature Accuracy 1C
Temp Controller Microprocessor Based Digital Temperature IndicatorCumController with LED OR LCD Display OR TFT Touch Screen Display Controller Option
Type Available with forced convection system
Regulator Solidstate electronic relay with protective heat sink
Safety Device Overtemperature limiter switch prevents overheating
To work on 220230V AV 5060 Hz supply

Verification Status