XLPE insulated high voltage power cable is used to transmit power on the power transmission and distribution line of A.C.50Hz, rated voltage 35kV or lower, and also used for Subway,Power station,Factory and Mine.It can be installed underground, in pipe, in trench or in tunnel. XLPE Cable not only has excellent electric character, mechanical character, heat and aging-resistant character, environmental stress-resistant character and chemical corrosion- resistant character, but simple structure, light weight, no restriction by laying drop, and high temperature allowance for long-term working as well.
XLPE insulated power cable is used to transmit power on the power tansmission and distribution of AC,rated voltage 35kv or lower.Incompatison with PVC insulation cable,It boasts not only excellent electric character,mechanical chatacter,heat and agingresistant character,environmental stress-resistant chatacter and chemical corrosionresistant chatacter,but simplw structure,light weight,no restiction by laying drop,and hight temperature allowance for long-term working as well. Executive standard 1)GB/T12706.1-2002(Equivalent IEC 60502) Rated voltage 1kv (Um=1.2kv)and power cable 2)GB/T12706.2-2002(Eqquivalent IEC60502-2)Rated voltage6 kvUm=7.2kv and Um=36kv power cable 3)G/BT12706.3(VOLTAGE Grade Overtep IEC 60502-2) Rated Voltage3.5V Um=40.5kv and power cable. Working consitions: 1) This maximum working temperatuie of thr conductor temperature is +90. During having a short (lasting less than 5 seconds )the maximum temperature of the cable conductor shall not be above +250 Environment temperture should be no lower than+0 for laying the cable. 2) Bending radius allowance of the cable: Single core cable:No steel tape cable 20D,steel tape cable 15D Cores cabel: No steel tape cable 15D steel tape cable 12D Notes: D ptactical esternal diameter of cable. Wooden drums
CU conductor PE insulation Twisted electrical wire belong to the series of laying electrical wire,which is mainly suitable for laying at the fixed places.It is widely used as lighting,connectors of drive, electric equipments,instrument and telecommunication equipments.The rated voltage is 450/750V(U0/U) or below.Part of the plastic wires are used at the equipment with AC rated voltage up to 300/300V . Electric wire is usually PVC insulated wire.This system include the below types: BV,BV-90,BVR, BVV,BLVV,BVVB,BLVVB,RVB,RVS,RVV BV Copper (aluminum) conductor PVC insulated w BLValuminum) conductor PVC insulated wires BVR Copper conductor PVC insulated flexible wires)* Copper (aluminum) conductor PVC insulated PVC sheathed round wires * Copper (aluminum) conductor PVC insulated PVC sheathed flat wires * Copper conductor PVC insulated flat flexible connectors * Copper conductor PVC insulated PVC sheathed round flexible connectors* Sizes: 0.5-185mm2* Standard: GB Standard and IEC Standard. GB 5023.11997450/750V or below PVC insulated electric wires,JB 8734.15-1998450/750V or under PVC insulated cables,electric wires and flexible wiresand Q/ZEL 02-2002Piastic insulated electric wires and cables.GB 5023.17-1997 is identical to IEC227,and type are same as the stipulation of IEC,technical specification is just the same,and more we have extended the range of the type to fit for the requipment of the consumers. We can also produce as per the other special requirements Coil
Control Cable are PVC insulation, XLPE insulation, fluoroplastic Insulation materials, different materials such as silicone rubber insulation performance cable products for In power stations, substations, factories, petrochemical, and other companies controlled remotely controlled loop, as the connection between the lines of various types of electrical instrumentation and automation devices, from the role of the various power or signal transmission, so that the entire electrical system safe, Reliable operation. Control cable is suitable for power station, substation, factory and petrochemical industry.
JSA Exports, a trusted name in the realm of import-export, offers a diverse range of high-quality electric cables. Our extensive selection encompasses a wide array of cables tailored to meet the demands of various industries and applications. Experience seamless connectivity and exceptional conductivity with our cutting-edge electric cables, designed to empower businesses worldwide.
Application :- The XLPE (Cross Link Poly Ethylene) Power Cables are used under ground as well as over head transmission of power in power plants, industries, projects and all other electrical installations. Features :- Manufactured from bright annealed 99.97% pure bare copper & aluminum conductors. These cables are insulated with XLPE compound. Taped/Extruded inner sheath. Round steel wire / flat galvanised steel grip armoured. The outer sheaths can be PVC, HR PVC, FRLS or FR depending upon the application and requirement. Technical Advantage of XLPE Insulation :- Higher current rating, higher short circuit rating (approx 1.2 times that of PVC), thermosetting in nature, higher insulation resistance (1000 times more than PVC cables), higher moisture resistance, better resistance to surge currents, low dielectric losses, better resistance to chemicals and corrosion, longer service life. Comparatively higher cable operating temperature 90�°C and short circuit temperature 250�°C. Technical Data :- Working Voltage : Up to 1100 V Temperature Range : -15�°C to +90�°C Power Cable Sizes : 1.50 Sq. mm to 400.00 Sq. mm in 2, 3, 3 Copper Control Cable Sizes : 1.50 Sq. mm, 2.50 Sq. mm up to 24 cores. Color Codes : 2 Core Cables - Red, Black 3 Core Cables - Red, Yellow & Blue 3 Core Cables - Red, Yellow, Blue & Black (for Neutral) 4 Core Cables - Red, Yellow, Blue & Black 5 Core Cables - Red, Yellow, Blue, Black & Grey 6 Core Cables & above - Adjacent cores are blue for reference and yellow for direction in each lay Black outer sheath Specification : IS:7098 (Part-1) Packing : 500 / 1000 meters on drums
Application :- The Power Cables are used under ground as well as over head transmission of power in power plants, industries, projects and all other electrical installations. Features :- Manufactured from bright annealed 99.97% pure bare copper & aluminum conductors. These cables are insulated with PVC compound. Taped/Extruded inner sheath. Round steel wire / flat galvanised steel grip armoured. The inner & outer sheaths can be PVC, HR PVC, FRLS, HR-FRLS or FR depending upon the application and requirement. Technical Data :- Working Voltage : Up to 1100 V Temperature Range : -15�°C to +70�°C or +85�°C in HR PVC Power Cable Sizes : 1.50 Sq. mm to 400.00 Sq. mm in 2, 3, 3 & 4 core. Copper Control Cable Sizes : 1.50 Sq. mm, 2.50 Sq. mm up to 24 cores. Color Codes : 2 Core Cables - Red, Black 3 Core Cables - Red, Yellow & Blue 3 Core Cables - Red, Yellow, Blue & Black (for Neutral) 4 Core Cables - Red, Yellow, Blue & Black 5 Core Cables - Red, Yellow, Blue, Black & Grey 6 Core Cables & above - Adjacent cores are blue for reference and yellow for direction in each lay Black outer sheath Specification : IS:1554 (Part-1) Packing : 500 / 1000 meters on drums