Our most advanced intelligent spot detectors, multi-criteria/multi-sensor devices use multiple sensors to detect various conditions in an environment sensing a wider range of fires with greater accuracy.
Features & Benefits:
Multi-Criteria/Multi-Sensor smoke detection
Unique ability to detect major elements of a fire
Highest nuisance alarm immunity
Advanced algorithms interpret and respond to multiple inputs
Honeywell BW Solo is a easy to service single-gas detector with BLE connectivity that provides real-time visibility into the status and safety of hazardous-area workers, helping companies respond faster, more knowingly and decisively to safety incidents. The first single-gas detector with the 1 Series sensor for CO, H2S and O2
Features & Benefits:
User-friendly operation,
Easy-to-read display for multiple languages,
Lightweight convenience,
Ease of maintenance,
Serviceability,
The new 1-Series sensor for enhanced reliability,
Connected Bluetooth Low Energy (BLE) capabilities.
H2-BF Hydrogen Sensor H2 Sensor Description
Alphasense is expanding its line of electrochemical Toxic Gas Sensors to address industry-specific requirements, including emissions monitoring, process safety, environmental monitoring and VOCs.
Hydrogen (H2)
The Hydrogen sensor has excellent ppm sensitivity for low concentrations to 2,000ppm H2. The very low sensitivity to CO makes this one of the most selective Hydrogen sensors on the market.
As with all Hydrogen sensors, temperature compensation for sensitivity must be applied carefully.
Available in A series.
H2-BF Hydrogen Sensor H2 Sens or Specifications
* Range: 5,000 ppm H2 limit of performance warranty
* Sensitivity: 10 to 25 nA/ppm in 400ppm H2
* Response time t90: < 55s from zero to 400ppm H2
* Resolution: < 0.8 RMS noise (ppm equivalent)
* Temperature range: -30 to 50 deg C
* Pressure range: 80 to 120 kPa
* Humidity range: 15 to 90 % rh
* Weight: < 13g
CM8 Carbon Monoxide Sensor Features:
1. More than ten years long life, electrochemical principle
2. Low sensitivity to ethanol;
3. Can reduce the influence of various interference gases, good linear output characteristics;
4. Consistency is very good;
5. The carbon monoxide gas selectivity and repeatability is very good;
6. The sensor signal output and the concentration of carbon monoxide gas into a linear relationship;
7. The leading production technology and new advanced materials;
8. Electrolyte pollution, materials comply with RoHS requirements;
9. Strong anti-interference;
10. The shell thicker will never rust, the new material used in component feet is conductive.
CM9 Carbon Monoxide Sensor Features:
1. More than ten years long life, electrochemical principle
2. Low sensitivity to ethanol;
3. Can reduce the influence of various interference gases, good linear output characteristics;
4. Consistency is very good;
5. The carbon monoxide gas selectivity and repeatability is very good;
6. The sensor signal output and the concentration of carbon monoxide gas into a linear relationship;
7. The leading production technology and new advanced materials;
8. Electrolyte pollution, materials comply with RoHS requirements;
9. Strong anti-interference;
10. The shell thicker will never rust, the new material used in component feet is conductive.
CM8 Carbon Monoxide Sensor Features:
1. More than ten years long life, electrochemical principle
2. Low sensitivity to ethanol;
3. Can reduce the influence of various interference gases, good linear output characteristics;
4. Consistency is very good;
5. The carbon monoxide gas selectivity and repeatability is very good;
6. The sensor signal output and the concentration of carbon monoxide gas into a linear relationship;
7. The leading production technology and new advanced materials;
8. Electrolyte pollution, materials comply with RoHS requirements;
9. Strong anti-interference;
10. The shell thicker will never rust, the new material used in component feet is conductive.
Performance
Output î¼a @ 20.9% o2 80 to 120
Response time t90 (s) from 20.9% to 0% o2 < 15
Zero current î¼a in n2 < 2.5
Linearity % o2 deviation @ 10% o2 0.6
Lifetime
Output drift % change in output @ 3 months < 1
Operating life months until 85% original output of 20.9% o2 > 24
Environmental
Humidity sensitivity % o2 change: 0% to 95% rh @ 40â?? < 0.7
Co sensitivity % (change o2 reading) / % co2 @ 5% co2 0.1
Pressure sensitivity (% change of output)/(% change of pressure) @ 20kpa < 0.1