Place of Origin: China Brand Name: OEM Model Number: FF01-18 Instrument classification: Class III, Class I, Class II Properties: Medical X-ray Equipments & Accessories Product name: hospital x ray cassettes Name: X-ray Equipment Application: X-ray Room .Radiography Department ~ Certificate: CE ISO Function: Medical Diagnosis Size: Customized Type: Xray Accessories Color: White Item: X-ray Equipment Material: X-ray Protective Material
Place of Origin : China Brand Name : OEM Power Source : Electric Warranty : 1 Year After-sale Service : Online technical support Material : Acrylic Shelf Life : 1 years Quality Certification : ce Instrument classification : Class I Safety standard : None Product Name : x-ray view box Application : X-ray Room Size : 50*800*105mm ODM : Accept Function : x ray film view Keyword : x-ray view box Color : White Certificate : CE ISO Feature : Stable Thickness : 105mm
Place of Origin: China Brand Name: OEM Model Number: CQ-TR Power Source: Electricity Warranty: 2 years, 2 Years After-sale Service: Online technical support Material: metal, Plastic Shelf Life: 1 years Quality Certification: ce Instrument classification: Class II Safety standard: GB/T18830-2009 Properties: Medical X-ray Equipments & Accessories view field: 75mm power supply: 220V/50HZ weight: 6kg Application: X-ray Room .Radiography Department ~ Name: portable x-ray machine Feature: Light Weight Certificate: CE ISO Package: Wooden Boxes
Place of Origin: China Brand Name: OEM Model Number: FC20 Power Source: None Warranty: Lifetime After-sale Service: NONE Material: Rare Earth, Gadolinium Oxysulfide Shelf Life: 6months Quality Certification: ce Instrument classification: Class I Safety standard: GB2626-2006 Power: X-ray Intensifying Screen Type: Universal protective Certificate: CE ISO Type 1: Blue sensitive 400 Type 2: Green sensitive 500 Speed: High speed Size for cassette: ALL available MOQ: 10 Customize: Available Function: Improve the overall quality of the X-ray image
Place of Origin: China Brand Name: OEM Model Number: HF-DP326 Power Source: Electric Warranty: 2 years After-sale Service: Free spare parts Material: Acrylic, metal, Plastic Shelf Life: 2 years Quality Certification: CB Instrument classification: Class III Safety standard: GB15979-2002 Name: X-ray Equipment Application: X-ray Room Certificate: CE ISO Power Supply: AC220V MOQ: 1set Function: Medical Diagnosis
Place of Origin: China Brand Name: OEM Model Number: MSLXF01 Instrument classification: Class II Properties: Medical-Ray Protective Products Product name: x ray film processor Developing capacity: 80 films/h (14"*17");145 films/h (10"*12") Rinse width: 4"*4"-14"*17" Develop time: 25/35/45sec Process time: 105/135/165secs Film sensing mode: micro switch Film feed mode: U-slot Dryer temperature: 40-65 Certificate: CE ISO Warranty: 2 years
High speed, high contrast fine grain film, for exposures in combination with RCF fluorometallic screens or fluorescent screens. High system speed is main requirement On stream corrosion/erosion radiography Concrete and heavy constructions Low dosage output, e.g. Microfocus
When you need to get to a patient fast, you need a durable, mobile X-ray imaging system. GE Healthcares AMX-4+ analog X-ray system answers that challenge by providing high-performance in a compact, easy-to-maneuver package. The rotating arm and tube simplify positioning and facilitate bedside studies, while the maintenance-free battery produces up to 50 high-quality exposures with a single charge. GE AMX4 Plus * Mobile X-ray * S/N : xxxxxxxxx * Excellent condition unit GE AMX 4 Plus Features GE Healthcares AMX 4+ analog X-ray system provides highperformance in a compact, easy-tomaneuver package. The rotating arm and tube simplify positioning and facilitate bedside studies, while the maintenance-free battery produces up to 50 high-quality exposures with a single charge. Dual drive motors and oversize casters facilitate movement; even in taxing environments.
Simplified User Interface A CR systems ease of use is critical to optimizing efficiency. The Flash IIP console workstation is the user interface to the XG5000 and it is the key to enhancing technologist workflow. Designed for patient identification, image review and image optimization, the Flash IIP integrates these multiple functions into one compact workstation. The simplified user interface automates processes to decrease errors and reduce the number of steps required to produce images meaning examinations are completed more quickly and patients spend less time in the waiting room. The minimal space requirements allow in-room installation and offer the most flexibility for placement. Multiple Flash IIP consoles can be networked to communicate with all of the FCR readers in the department, improving flexibility and reducing potential workflow bottlenecks. Standard Component XG5000 high capacity Image Reader (CR-IR 362) Throughput 150 IPs/hour average (103-165 IPs/hour) Image Preview 15-25 seconds DICOM Connectivity DICOM Modality Worklist Management DICOM CR Store SCU DICOM Basic Gray Scale Print SCU DICOM Storage Commitment DICOM Modality Performed Procedure Step Reading Gray Scale: 12 bits Network: 10 Base T/100 Base T Dimensions (W x D x H): 26 x 29 x 58 (655 x 740 x 1480mm) Weight: 628 lbs. (285kg) Power Supply Conditions: Single phase 50~60Hz 120-240V±1 Sizes 14³ x 17³ (35 x 43cm) 14?³ x 1³ (35 x 35cm) 10³ x 12³ 8³ x 10³ 18 x 24cm 24 x 30cm Number of Pixels HQ Standard 14³ x 17³ 3520 x 4280 pixels 1760 x 2140 pixels 14³ x 14³ 3520 x 3520 pixels 1760 x 1760 pixels 10³ x 12³ 2505 x 3015 pixels 1670 x 2010 pixels 8³ x 10³ 2000 x 2510 pixels 2000 x 2510 pixels 24cm x 30cm 2364 x 2964 pixels 1576 x 1976 pixels 18cm x 24cm 1770 x 2370 pixels 1770 x 2370 pixels Fuji XG5000 CR High Capacity Digital X-ray DOM: 10/2004 Each system will include: Dell IIP Workstation (2) 14-17 Type-C Cassettes w/ST-VI IMAGING PLATES (2)10-12 Type-C Cassettes w/ST-VI IMAGING PLATES
1. When adding up voltage, total current is less than 2a and total power is 500w; 2. The current and voltage of x-ray tubes are fixed in three groups, they are: X exposure voltag (kvp) 60 65 70 X-ray current (ma) 0.5 0.85 1.10 3. When adding up voltage, total current is less than 2a and total power is 500w 4. Drain current and earth resistance are in accordant with the stipulates in gb9706.1 5. The three groups of voltage (60kv, 65kv, 70kv) are adjustable. 6. Wireless remote control in any angles within 10 meters part form the control box 7. The parameter of x-ray generator (bulb tube head) the parameter of x-ray tubes A focus index: 0.3*0.3mm2 B. The voltage of the-highest-voltage generator: 90kv C. The highest inverse peak voltage: 90kv D. Filament characteristic: vf=5v+0.5v, f=3a E. Target surface obliquity: 12 F. The cooling manner of bulb tube head: oil immersion The parameter of x-ray generator (bulb tube head): A. Focus-skin distance: 200mm B.The thickness of filter-ray film: more than 1.5mmal C.The leakage rate of x-ray: no more than 0.002mgy/h (no. 29.204.3 in gb9706.12 prescript that the leakage rate of x-ray is no more than 0.25mgy/h) D. The manner of limiting beam: using planigraphic device
Detecting such as stone ,sand,teflon,fe,sus ,non-fe,harder material and so on in the food stuff
X-ray machine Technical parameter 1. The numbers of x-ray tubes used in the product are also used as product number and x-ray generator (bulb tube head) number. 2. The current and voltage of x-ray tubes are fixed in three groups, they are: X exposure voltageú¿kvpú¬ 60 65 70 X-ray currentú¿maú¬ 0.50 0.85 1.10 3. When adding up voltage, total current is less than 2a and total power is 500w 4. Drain current and earth resistance are in accordant with the stipulates in gb9706.1 5. The three groups of voltage (60kvíó65kvíó70kv) are adjustable. 6ú«wireless remote control in any angles within 10 meters part form the control box 7. The parameter of x-ray generator (bulb tube head) 7.1. The parameter of x-ray tubes A. Focus index: 0.3í-0.3mm2 Bú«the voltage of the-highest-voltage generator: 90kv C. The highest inverse peak voltage: 90kv D. Filament characteristic: vf=5ví+0.5vú¼if=3a E. Target surface obliquity: 12íp F. The cooling manner of bulb tube head: oil immersion 8.7.2 the parameter of x-ray generator (bulb tube head): A. Focus-skin distance: 200mm B. The thickness of filter-ray film: more than 1.5mmal C. The leakage rate of x-ray: no more than 0.002mgy/h (no. 29.204.3 in gb9706.12 prescript that the leakage rate of x-ray is no more than 0.25mgy/h) D. The manner of limiting beam: using planigraphic device
Technical parameter 1. The numbers of x-ray tubes used in the product are also used as product numbers and x-ray generator (bulb tube head) numbers. 2. The current and voltage of x-ray tubes are fixed in three groups, they are: X exposure voltage (kvp) 60 65 70 X-ray current (ma) 0.50 0.85 1.10 3. When adding up voltage, total current is less than 2a and total power is 500w 4. Drain current and earth resistance are in accordant with the stipulates in gb9706.1 5. The three groups of voltage (60kv, 65kv, 70kv) are adjustable. 6. Wireless remote control in any angles within 10 meters part form the control box 7. The parameter of x-ray generator (bulb tube head) 7.1. The parameter of x-ray tubes A. Focus index: 0.3í-0.3mm2 B. The voltage of the-highest-voltage generator: 90kv C. The highest inverse peak voltage: 90kv D. Filament characteristic: vf=5ví+0.5v, if=3a E. Target surface obliquity: 12íp F. The cooling manner of bulb tube head: oil immersion 7.2 the parameter of x-ray generator (bulb tube head): A. Focus-skin distance: 200mm B. The thickness of filter-ray film: more than 1.5mmal C. The leakage rate of x-ray: no more than 0.002mgy/h (no. 29.204.3 in gb9706.12 prescript that the leakage rate of x-ray is no more than 0.25mgy/h) D. The manner of limiting beam: using planigraphic device
XX- line of portable X-ray units is designed to the principle of low cost and high reliability, which is characteristic in convenient to carry, easy to operate, and highly automated. X-ray tube and HT coil are all produced by DANDONG NDT which guarantees system consistency. Weight is further reduced with the use of SF6 insulation. Forced cooling fan guarantee the longevity of X-ray tube, which makes the product suitable for field and highly above work. K03/K05 control unit is microprocessor controlled with module of controlled silicon voltage adjustment and frequency conversion. The functions of fully automatic warm-up program, fault display, over voltage and mis-start protection, the stability and service life are much improved. 655 ¬200mm 15kg
100 mA Mobile x-ray machine. very good image quality. built in stabilizer. works on 220v AC.
9-inch/12-inch/6-inch 20mm/25mm image output high dqe high resolution high contrast high definition high image quality x-ray image intensifier (xrii) for image intensifier tv system (ii tv) and x-ray fluoroscopy x-ray machine, c-arm x-ray machine, industrial inspection x-ray machine More info plz contact: Lina Whatsapp: +86-15653608205 Skype: lina zhang-newheek E-mail: newheeklina@163.Com Web: www.Newheek.Com
Tube stand (xts-01) Type : floor-to-ceiling rail Distance of longitudinal travel : 2550mm Distance of vertical travel : 1600mm Rotation of x-ray tube : ±180° Lock system : electromagnetic lock by manual Weight : 170kg Ceiling (xce-01, option) Type : ceiling rail Distance of longitudinal travel : 2800mm Distance of vertical travel : 1200mm Rotation of x-ray tube : ±180° Lock system : electromagnetic lock by manual Weight : 130kg Bucky stand (xbs-01, option) Type : vertical travel Distance of vertical travel : 120mm ~ 1780mm X-ray grid : grid ratio of 8:1, 103 line/inch Front plate to film distance : 50mm Weight : 105kg 4way type bucky table (xbt4-01) Type : 4way travel Longitudinal distance of tabletop sliding : 420±5mm Lateral distance of tabletop sliding : 120±5mm Tabletop to floor distance : 665mm X-ray grid : grid ratio of 8:1, 103line/inch Dimensions : 2000l x 750w x 665h (mm) Weight : 150kg 6way type bucky table (xbt6-01, option) Type : 6way travel Drive type : electric motor drive X-ray grid : grid ratio of 8:1, 103line/inch Longitudinal distance of tabletop sliding : 420±5mm Lateral distance of tabletop sliding : 120±5mm Vertical distance of tabletop : 300±5mm Tabletop to floor distance : 689(880)mm Dimensions : 2000l x 750w x 680(880)h (mm) Weight : 170kg High voltage cable (hvc-6/8) Length : 6m/8m Maximum voltage : dc 75kv The number of core line : 3 lines
NDT X ray equipment is used for inspect the inner fault of the material. It adopts radiography theory to make the image on the film, in order to evaluate the work piece. Features of X Ray Generator: Adopt high temperature installation technology and high pure degree aluminum radiator to improve 30% heat radiation. Portable design, light weight and easy operation. SF6 gas insulator, grounded-anode design to keep the operator safety. Strictly follow 1:1 work and rest radio, eliminating the disoperation. Good HV coil made by imported enamel wire in the generator to improve the power. Glass tube Panoramic XXH-1005 Power(KW) >1.0 , Beam Angle: 360*25 ,Max.Penetration A3 steel (mm) : 6 XXH-1605 Power(KW) >1.5 , Beam Angle: 360*25 ,Max.Penetration A3 steel (mm) : 18 XXH-2005 Power(KW) >2.0 , Beam Angle: 360*25 , Max.Penetration A3 steel (mm) : 26 XXH-2505 Power(KW) >2.5 , Beam Angle: 360*25 , Max.Penetration A3 steel (mm) : 36 XXH-3005 Power(KW) >3.0 , Beam Angle: 360*25 ,Max.Penetration A3 steel (mm) : 46 XXH-3505 Power(KW) >3.5 , Beam Angle: 360*25 , Max.Penetration A3 steel (mm) : 56 Glass tube Directional XXQ-1005 Power(KW) >1.0 , Beam Angle: 40 , Max.Penetration A3 steel (mm) : 8 XXQ-1605 Power(KW) >1.5 , Beam Angle: 40 , Max.Penetration A3 steel (mm) : 20 XXQ-2005 Power(KW) >2.0 , Beam Angle: 40 , Max.Penetration A3 steel (mm) :29 XXQ-2505 Power(KW) >2.5 , Beam Angle: 40 , Max.Penetration A3 steel (mm) : 39 XXQ-3005 Power(KW) >3.0 , Beam Angle: 40 , Max.Penetration A3 steel (mm) : 49 XXQ-3505 Power(KW) >3.5 , Beam Angle: 40 , Max.Penetration A3 steel (mm) : 59 Ceramic tube directional XXG-1605 Power(KW) >1.5 , Beam Angle: 40 , Max.Penetration A3 steel (mm) : 20 XXG-2005 Power(KW) >2.0 , Beam Angle: 40, Max.Penetration A3 steel (mm) : 29 XXG-2505 Power(KW) >2.5 , Beam Angle: 40 , Max.Penetration A3 steel (mm) : 39 XXG-3005 Power(KW) >3.0 , Beam Angle: 40 , Max.Penetration A3 steel (mm) : 49 XXG-3505 Power(KW) >3.5 , Beam Angle: 40°, Max.Penetration A3 steel (mm) : 59 wooden case 80KG