We're a leading XRay machine and accessories manufacturer company with over 29 years of experience and global presence and distributor network in 7 different countries. We have Line Frequency & High Frequency, APR X-Ray Machine, Dental X-Ray Machine, Mobile 100MA X-Ray Machine, 300MA X-Ray Machine, 500MA XRay Machine, Vertical Bucky, Multi-Position Bucky Table, 4 & 2 Way Floating Bucky Table Etc Beside new machines, we offer complete modification & repairing of any brand XRay machines, Rotating Anode Tube Head, HT 100MA, 300MA, 500MA Etc
Power Output 5.0KW x ray machine Main Inverter frequency 40 KHz X-ray Tube of radiography machine fixed anode focus: 1.5 (X-ray tube for high frequency) Power Supply 220V�±10% 50Hz Inner-resistance â?¤1.0�© Operation Method Wire/wireless control mobile x-ray machine safety mobile x ray machine cost mobile x ray machine price
Power Output 5.0KW Frequency 40KHz Power Supply 220V± 10% 50Hz inner-resistance Operation Method Wire/Wireless control mobile x ray machine cost mobile x ray machine price mobile x ray machines ww1
Mobile 100mA high frequency X-ray system PLX101C for sale Item Contents Environmental Conditions No erosive volatile gas and dust around Temperature +10â??~+40â?? Relative Humidity 30%~75% Atmospheric Pressure 700 hpa~1060hpa Power Output 5.0KW Frequency 50kHz Tube Voltage 40~120KV Power Supply 220V±10% 50/60HZ Internal Resistance less than input power 9kVA Operation Method Wire/Wireless Control Dimension 120cm*62cm*130cm Net Weight 150kg mobile x ray machine cost mobile x ray machine price mobile x ray machine ww1
2.5kw high frequency portable X-ray machines PLX101 x ray tube Fixed Anode Power Output of x ray machine 2.5kW Frequency 25kHz Tube voltage 40~100kV Power Supply 220V�±10%, 50kHZ Operation Method Wire/ Wireless control price list of x-ray machine price of 500ma x-ray machine price of medical x ray machine
brand of surgical x-ray equipment PLX101D mobile x ray machine for sale price of x ray machine mobile x ray machine specifications Power Output 5.0KW x ray machine Main Inverter frequency 40 KHz X-ray Tube of radiography machine fixed anode focus: 1.5 (X-ray tube for high frequency) Power Supply 220V±10% 50Hz Inner-resistance Operation Method Wire/wireless control
X-ray protective Aprons - Lead Apron - Lead-Free Apron
X ray tube technology parameters  Testing equipment using x ray tube Mainly used for application in the heat, pressure vessel, aviation, aerospace, electric power, petroleum, chemical, pipeline, military industry, nuclear industry, shipbuilding, automobile, metallurgy, steel structure, railway, university, luggage and parcel safe industries such as manufacturing, production, quality control links. mode Tube voltage Tube current spots Filament voltage ThefilamentcurrentRadiation Angle (KVp) (mA) (mm) (V) (A) (°) The length of the XA33A 160 2 0.8* 0.8 5.3 4.4 40°+5° 68mm190mm XA33B 160 4 0.3*0.8 4 3.5±0.2 110°�40° 68mm190mm XA33C 160 4 2.5*0.8 3.5±0.2 3.7±0.2 110°�20° 68mm190mm XA33D 160 2 0.8* 0.8 3.5±0.2 3.70±0.2 80°�60° 68mm190mm XA33E 160 4 0.8*0.8 3.5±0.2 3.7±0.2 60° 68mm190mm XA33F 160 5 0.8*0.8 3.5±0.2 3.7±0.2 40°�60° 68mm190mm XA33G 200 3 1.5*1.5 4.6±0.2 3.4±0.2 80°�60° 211mm XA36H 100 1.4 0.6�0.6 5±0.2 2.1±0.2 40°�60° ���mm
X ray tube technology parameters Testing equipment using x ray tube Mainly used for application in the heat, pressure vessel, aviation, aerospace, electric power, petroleum, chemical, pipeline, military industry, nuclear industry, shipbuilding, automobile, metallurgy, steel structure, railway, university, luggage and parcel safe industries such as manufacturing, production, quality control links. specifications Tube Tube Filament The filament spots size voltage current voltage current �KV) �mA) (V) (A) (mm) (mm) XA-801 80 1.5 5±0.5 2.1 0.8*0.8 116±1 XA-801A 80 1.5 5±0.5 2.1 0.8*0.8 116±1 XA-1001 100 1.5 5±0.5 2.1 0.8*0.8 116±1 XA-1001A 100 1.5 5±0.5 2.1 0.8*0.8 116±1 XA-1402 140 2.5 5±0.5 4 0.8*0.8 190±2 XA-1402A 140 2.5 5±0.5 4 0.8*0.8 190±2 XA-1602A 160 2.5 5±0.5 4 0.5*0.5 190±2 XA-2003 200 2.5 5±0.2 4 1.5*1.5 211±1
X ray tube technology parameters  Testing equipment using x ray tube Mainly used for application in the heat, pressure vessel, aviation, aerospace, electric power, petroleum, chemical, pipeline, military industry, nuclear industry, shipbuilding, automobile, metallurgy, steel structure, railway, university, luggage and parcel safe industries such as manufacturing, production, quality control links.  mode Tube voltage Tube current spots Filament Thefilame Radiation Angle voltage ntcurrent (KVp) (mA) (mm) (V) (A) (°) XA33A 160 2 0.8* 0.8 5.3 4.4 40°+5° XA33B 160 4 0.3*0.8 4 3.5±0.2 110°�40° XA33C 160 4 2.5*0.8 3.5±0.2 3.7±0.2 110°�20° XA33D 160 2 0.8* 0.8 3.5±0.2 3.70±0.2 80°�60° XA33E 160 4 0.8*0.8 3.5±0.2 3.7±0.2 60° XA33F 160 5 0.8*0.8 3.5±0.2 3.7±0.2 40°�60° XA33G 200 3 1.5*1.5 4.6±0.2 3.4±0.2 80°�60° XA36H 100 1.4 0.6�0.6 5±0.2 2.1±0.2 40°�60°
Place of Origin : China Brand Name : OEM Power Source : Electric Warranty : 1 Year After-sale Service : Online technical support Material : Acrylic Shelf Life : 1 years Quality Certification : ce Instrument classification : Class I Safety standard : None Product Name : x-ray view box Application : X-ray Room Size : 50*800*105mm ODM : Accept Function : x ray film view Keyword : x-ray view box Color : White Certificate : CE ISO Feature : Stable Thickness : 105mm
Place of Origin: China Brand Name: OEM Model Number: FF01-18 Instrument classification: Class III, Class I, Class II Properties: Medical X-ray Equipments & Accessories Product name: hospital x ray cassettes Name: X-ray Equipment Application: X-ray Room .Radiography Department ~ Certificate: CE ISO Function: Medical Diagnosis Size: Customized Type: Xray Accessories Color: White Item: X-ray Equipment Material: X-ray Protective Material
FDR-3201 sulfur content analyzer (X-ray spectroscopy) Scope This instrument conforms to the standards GB / T11140, GB / T17040, ASTM D4294 and ASTM D2622. The instrument is suitable for the determination of trace amounts of sulfur in petroleum products. Because it uses physical analysis method, high analysis speed, no sample pretreatment, high accuracy, little artificial error, the operator labor intensity is low, no pollution, this analysis method has being widely used in the international and replace the other sulfur analysis method. Features 1, the instrument uses a full English operating system, human-friendly communication interface. 2, detection time is short, automatically detect the results within 30 seconds; automatic C / H ratio correction, which is suitable for a variety of samples; 3, large-screen LCD display, automatically print measurement data; 4, the instrument uses the X-ray tube excitation, so that the instrument can be long-term use, without being affected by the source attenuation; 5, the instrument uses a physical analysis method, the analysis does not touch and destroy the sample, no chemical reagents; 6, the instrument uses an integrated design, easy maintenance; Technical Parameters 1, the scope of analysis: S analysis range can be adjusted, the user can calibrate the work curve to select the scope of the analysis. 2, the width of the analysis range: S% max-S% min â?¤ 9.999%; for example, oil: S: 0.001 ~ 9.999%. 3, the inherent error, analysis accuracy: for example, oil: in line with national standards GB / T 17040, in line with the US national standard ASTM D4294 related requirements. 4, the system analysis time: 1 ~ 999 seconds, the recommended value of 60 seconds. 5, detection limit: 10ppm 6, the use of conditions: Ambient temperature: 5 ~ +40 â??, relative humidity: â?¤ 85% (30 â??), power supply: 220V ± 20V, 50Hz. 7, the whole power consumption:
New & Refurbished Systems Available!!! We Offer New, Used, And Refurbished Portable X-Ray Systems. Amx4, Amx4 Plus, Dynarad And Many More!!!
X-Ray View Box
Item Code 18.09.001 Specification 18.09.002 : X-Ray Viewer Single Film 18.09.003 : X-Ray Viewer Double Film 18.09.004: X-Ray Viewer Triple Film 18.09.005: Snellen Chart Single Sided (for litrate) 18.09.006: Snellen Chart Single Sided (for Illitrate)
Microfocus Fusion 5 X-ray Machine Suitable for SMT and semiconductor components
x-ray baggage scanner
x-ray film processing chemicals
Main specification Hf generator110kv, 3.5kw , 40khz Fluoroscopy modefluoroscopy mode40~110kv 0.5~5ma (kv manual and automatic); Pulsd fluoroscopy 40~110kv 0, 5-5ma Boost fluoroscopy 40~110kv 5~10m Photography 40~110kv 1~250mas X ray tubedual-focus fixed anode:0.6mm/1.5mm Italy imd technology Image intensifierthree fields of vision 9, 6, 4.5 french thales brand Ccd cameraccd camera, japanese watt brand, 360rotation Image systemrecursive noise reduction Frame freezing Multi frame image storage Image conversing and rotating Screen display with image comparison Mechanical motion specificationsverticaltravel:0-400mm horizontaltravel:0~200mm rotation about horizontal axis:180 C-arm dimensiondistance of focal spot to image generator(sid):1000mm Depth in arm 650mm Mobile stand :1800mm*800mm*1850mm Image system: 750mm*530mm*1680mm Standard configurationhigh resolution ccd camera:1set X-ray generator:1set 9 image intensifier:1set Digital noise reduction system 15 high resolution monitor :2sets Mobile stand :1 set