Pressure range: -1 20 bar(optional) Accuracy: 1%F.S. Supply voltage: 5VDC, 12VDC, 3.3VDC Output: 0.5-4.5V, Others on request Operating temperature: -40 105 Compensation temperature: -20 80 Operating Current: 3mA Temperature drift (zero & sensitivity): 0.03%FS Long-term stability: 0.2%FS/year Response Time: 4ms Overload pressure: 150%FS Burst pressure: 300%FS Cycle life: 500,000 times Pressure connection: NPT1/8 by default, Others on request Electrical connection: Packard connection Housing Material: Copper Shell Water-proof level: IP65 Explosion-proof level: Exia CT6 Weight: 0.08kg Medium: non-corrosive environment Sensor core: Al2O3-96% ceramic sensor Cable length: 0.3m for Packard, 0.5m for plastic direct cable by default
Function & Feature 1. Isolate the DC input signal from the DC Output signal, which is directly proportional to the input signal. 2. These isolators can be used to prevent earth loops, which occur when a measuring source 3. Excellent temperature characteristic and good working stability. 4. It have an advantage over loop powered units, in that if for any reason the output lead should become disconnected, the input will not be saturated. 5. Fixed in a standard 35mm DIN rail or screwed on the cabinet.
Function & Feature 1. QPCX electrical transducer converts ac current and voltage signals into a load independent dc signal proportional to active power (watt), reactive power (var) and power factor (PF). With an extra output channel for customized. Total four channel output for electrical data sampling use. 2. The current and voltage signals are passed into the circuit via precision instrument transformers to provide galvanic isolation between the input circuits and the transducer circuitry. Each pair of current and voltage signals is mathematically multiplied together to produce a product signal proportional to true power and independent of wave shape and phase angle. 3. This combination transducers with RS485 communication port, it can be connected to a variety of measuring and control devices and systems, such as analogue meters, PLC, computers, data loggers, digital instruments and telemetry systems. 4. Snap on to DIN rail 35 x 7.5 mm complies with DIN-EN 50022 BS 5584
Function & Feature 1. QPPX electrical transducer measures a wide range of electrical parameters and generates analog or digital output signals suitable for interfacing with instrumentation and control systems. Total four channel output, with panel key or PC control programmable, user can free to set 4 different data from max 26 electrical parameter for sampling and analog signal output. 2. Have three channel digital inputs and optional RS485-Modbus communication functionality. Can monitor the galvanically isolated DI signal and programmed the transducer with customized SCADA software. Any of the measured parameters can be read out via the optional RS485-Modbus connection. 3. QPPX also can be used to configure the connection to the measured circuit for single-phase, three-phase three-wire, three-phase four-wire, balanced or unbalanced load. Can be connected to a variety of measuring and control devices and systems, such as analogue meters, PLC, computers, data loggers, digital instruments and telemetry systems. 4. Snap on to DIN rail 35 x 7.5 mm complies with DIN-EN 50022 BS 5584
Function & Feature 1. Isolate the DC input signal from the DC Output signal, which is directly proportional to the input signal. 2. These isolators can be used to prevent earth loops, which occur when a measuring source 3. Excellent temperature characteristic and good working stability. 4. It have an advantage over loop powered units, in that if for any reason the output lead should become disconnected, the input will not be saturated. 5. Fixed in a standard 35mm DIN rail or screwed on the cabinet.
Function & Feature 1. QPPX electrical transducer measures a wide range of electrical parameters and generates analog or digital output signals suitable for interfacing with instrumentation and control systems. Total four channel output, with panel key or PC control programmable, user can free to set 4 different data from max 26 electrical parameter for sampling and analog signal output. 2. Have three channel digital inputs and optional RS485-Modbus communication functionality. Can monitor the galvanically isolated DI signal and programmed the transducer with customized SCADA software. Any of the measured parameters can be read out via the optional RS485-Modbus connection. 3. QPPX also can be used to configure the connection to the measured circuit for single-phase, three-phase three-wire, three-phase four-wire, balanced or unbalanced load. Can be connected to a variety of measuring and control devices and systems, such as analogue meters, PLC, computers, data loggers, digital instruments and telemetry systems. 4. Snap on to DIN rail 35 x 7.5 mm complies with DIN-EN 50022 BS 5584 Specifications Inputs: Nominal input 1 or 5 Amp C.T. connected 110V, 230V, 240V, 400V, 415V ac +/-20% Power consumption
Function & Feature 1. Have microcontroller technology as the core, using the latest algorithms, to achieve precise measurement. 2. Current transducer converts an ac current input into a load independent output signal. 3. Excellent temperature characteristic and good working stability. 4. The output signal is based on the a root mean square(rms) measurement of the input signal and hence the transducer can be used with distorted waveforms. 5. The unit conforms to IEC 60688. In an addition it meets the insulation requirements of IEC 60255-5, clauses 5, 6 and 8 as well as the high frequency disturbance test of IEC 60255-22 for Class III test voltage. Specifications Inputs: System current 1A, 5A, 10A, 30A Absorbed power 0.3VA Frequency range 50Hz, 60Hz Output: Standard nominal outputs 4~20mA, 0-5V, (others on request) 0-20mA, 5-10V 0-10V Ripple
Function & Feature 1. QPCX electrical transducer converts ac current and voltage signals into a load independent dc signal proportional to active power (watt), reactive power (var) and power factor (PF). With an extra output channel for customized. Total four channel output for electrical data sampling use. 2. The current and voltage signals are passed into the circuit via precision instrument transformers to provide galvanic isolation between the input circuits and the transducer circuitry. Each pair of current and voltage signals is mathematically multiplied together to produce a product signal proportional to true power and independent of wave shape and phase angle. 3. This combination transducers with RS485 communication port, it can be connected to a variety of measuring and control devices and systems, such as analogue meters, PLC, computers, data loggers, digital instruments and telemetry systems. 4. Snap on to DIN rail 35 x 7.5 mm complies with DIN-EN 50022 BS 5584 Specifications Inputs: Nominal input 1 or 5 Amp C.T. connected 110V, 230V, 240V, 400V, 415V ac +/-20% Power consumption
Push button switch, circuit breaker and over, under voltage protector, pressure transducer, temperature sensor.
1.Type: convex array 2.Frequency: 3.5MHz 3.Compatible system: HIVision 6500, HiVision 5500,EUB-6000, EUB-6500 4.Application:Obstetrics,Abdominal 5.Condition: pre-owned one, original, in good working condition 6.With 60 days warranty
Toshiba PVT-661VT Endovaginal 10mm transducer 1.Type: Endovaginal 2.Frequency: 3-9MHz 3.Compatible system: Aplio 50 SSA-700A, Aplio SSA-750A, Xario SSA-660A 4.Condition: pre-owned and original, in good working condition 5.With 60 days warranty
Toshiba PLT-805AT Linear 56 mm Ultrasound Transducer 1.Type: linear 2.Frequency: 6.2-12.0 Mhz 3.Compatible system: Aplio 50 SSA-700A, Aplio SSA-750A, Aplio SSA-770A, Xario SSA-660A 4.Application: peripheral vascular and small part 5.Condition: pre-owned and original, in good working condition 6.With 60 days warranty
Rated input current AC 50A, 100A, 400A AC/DC Accuracy 1.0 Input Impedance (R) approximate zero Linear measuring range 0 - 1.2 times of rated input current Over Load Capacity 30 times of rated input current, 5s Frequency range 25Hzï½?5kHz Isolation Voltage(Input/Output) â?¥2500Vdc, for 1 minute Thermal drift 600ppm/°C Ambient Temperature -25ï½?+70 Mounting DIN Rail 35mm Mounting or screw mounting
Rated input current AC 50A, 100A, 400A AC/DC Accuracy 1.0 Input Impedance (R) approximate zero Linear measuring range 0 - 1.2 times of rated input current Over Load Capacity 30 times of rated input current, 5s Frequency range 25Hz~5kHz Isolation Voltage(Input/Output) 2500Vdc, for 1 minute Thermal drift 600ppm/ Ambient Temperature -25~+70 Mounting DIN Rail 35mm Mounting or screw mounting
Nominal current(rms):50/100/200/300/400/600a Voutipn:+4.000v Measuring range:0~+900a Supply voltage dc:+15v Accurancyipn, +25degree Celsiusless than1.0% Mounting(mm):10.5*20.5 * open- loop supply voltage: dc +15.0v * capable measurement of currents: dc, ac, pulse with galvanic isolation between primary circuit and secondary circuit.
Nominal Current(RMS):30/300A Vout@Ipn:2.500+_2.000V Measuring Range:+_30/+_300A Supply VoltaIpn,+25
P/N: M2734B hp TOCO Transducer 100% original Latex free one year warranty 1pcs/box
Function & Feature 1. Isolate the DC input signal from the DC Output signal, which is directly proportional to the input signal. 2. These isolators can be used to prevent earth loops, which occur when a measuring source 3. Excellent temperature characteristic and good working stability. 4. It have an advantage over loop powered units, in that if for any reason the output lead should become disconnected, the input will not be saturated. 5. Fixed in a standard 35mm DIN rail or screwed on the cabinet. 6. Ultra-thin dimension, suitable for limited space, the control cabinet.
Function & Feature 1. QPK transducer converts ac current and voltage signals into a load independent dc signal proportional to reactive power (vars). This signal is capable of driving a number of independent instruments. 2. The current and voltage signals are passed into the circuit via precision instrument transformers to provide galvanic isolation between the input circuits and the transducer circuitry. Each pair of current and voltage signals is mathematically multiplied together to produce a product signal proportional to true power and independent of wave shape and phase angle. 3. These var transducers to be connected to a variety of measuring and control devices and systems, such as analogue meters, PLC, computers, data loggers, digital instruments and telemetry systems. 4. Snap on to DIN rail 35 x 7.5 mm complies with DIN-EN 50022 BS 5584
Function & Feature 1. Isolate the DC input signal from the DC Output signal, which is directly proportional to the input signal. 2. These isolators can be used to prevent earth loops, which occur when a measuring source 3. Excellent temperature characteristic and good working stability. 4. It have an advantage over loop powered units, in that if for any reason the output lead should become disconnected, the input will not be saturated. 5. Fixed in a standard 35mm DIN rail or screwed on the cabinet. 6. Ultra-thin dimension, suitable for limited space, the control cabinet.