Ultrasonic Transducers Name Method Eg, UCE-6845D-20LA PZT8 UCE mean our company logol. 68 is stand for the dimetions of radiation head, 45 is stand for the dimetions of the piezoelectric ceramic,PZT8 is mean the material of piezoelectric ceramic,PZT8 is yellow ceramic,PZT4 is black. Ultrasonic Transducers is one of main products of at UCE ultrasonic,which used the piezoelectric effort to realize transduction between electric and sound energy,also named as BLT transducer,ultrasonic transducer normally used in ultrasonic cleaning industry,high power ultrasonic etc.
Electropneumatic transducer Input electrical current:4-20ma, 0-10v Output pressure:20-100kpa Et-500 is electropneumatic transducer equipment, it can decrease supply pressure to produce output pressre which is effectively proportional to input electric signal. Supply pressure range:125kpaí½1000kpa.With bulk augmenter supply big flow (20.4 m3/h). Features: Flow rate: 7.6m3/h when supply pressure is 175kpa 20.0m3/h when supply pressure is 700kpa Min/max. Supply pressure: Minimum-3psig(21kpa) above maximum output Maximum-100psig(700kpa) Sensitivity:
"FAMAGA Group OHG, the global supplier of industrial equipment and spare parts, is glad to provide encoders by Transducers SENECA: We supply a complete range of the manufacturerâ??s catalog, including the following items: SENECA T201 SENECA Z109REG2 SENECA Z-SG SENECA �¢201 SENECA T201DC SENECA T201DCH100 SENECA K121 SENECA 1K-RS65-03 SENECA T201DCH300-LP SENECA T201DCH300 SENECA T201DCH100-LP SENECA Z-SG-L SENECA Z-10-D-IN SENECA Z170REG-1 SENECA S105TCS-3 SENECA Z-PC-DINAL2 SENECA Z-PC-DINAL2-17.5 Our company is also pleased to offer products of other brands: Bei Sensors IBH Softec Schmersal BALLUFF Pepperl+Fuchs Bernstein Di-Soric Elobau Univer Eltra Aventics FESTO Camozzi Euchner END-Armaturen TAMAGAWA SENECA Airtac Murrelektronik Azbil Yamatake FRANKE-Filter Endress+Hauser IFM Ipf Electronic Kieback & Peter MD Micro Detectors Bihl Wiedemann ANDERSON-NEGELE KITAGAWA Georg Schlegel Metal Work Kipp Allen-Bradley Netter Vibration Kuebler / K�¼bler RAFI LINDY 4B Braime SOUTHCO ELGO Electronic FAG RECO Pilz AIRTEC Pneumatic COMITRONIC-BTI L�¼tze Hydac Barksdale Keyence AirCom Pneumatic Garlock Mac Valves MAHLE (Filtration Group) Riegler Baumer Elreha Sick Siko FAMAGA Group OHG is a family-owned company with many years of experience in the supply of components and spare parts for industrial enterprises around the world. Our mission is to provide fair prices, reducing the cost of production for our customers. A significant network of suppliers around the world allows us to supply any equipment, which client needs on favorable terms. Therefore, the list of equipment we provide is tenfold greater than the catalog presented on this site. You are welcome to check the full catalog on our website."
Type includes:TAT Transducer,Static Temperature Transducer,Platinum Resistance Temperature sensor,Thermocouple Transducer,AWT Wireless temperature sensor Performance TAT Transducer senses the air temperature of the stagnation point and output resistance signal Operation temperature range:-60 ? ~+350? Type:GZW-3, GZW-6, GZW-7 Static Temperature Transducer Measures the static T of air or liquid and provides resistance output accordingly. Measure range: -60?~300? Error less than ±1? Platinum Resistance Temperature sensor Measurement Range: -60?~300? Tolerance: d=±(0.5+5×10 -3 t)? Type: GWR-24, GWR-24A,GWR-31/31A,GWR-39, GWR-92, GWR-95 Thermocouple Transducer Use a thermocouple to sense the temperature of the environment or air flow, and produce a voltage signal (mv) Temperature range: 0ºC~900ºC AWT Wireless temperature sensor Model:AWT-GN-DU1 Characters: 1.Low power consumption, long standby time 2.High measurement accuracy 3.Adjustable sampling rate(10min~12h) 4.Zigbee wireless communication protocol 4.long distance transmission 5. Full Metal Package with the IP65/67 Protection class 6.Good appearance
Consistent and accurate readings during blood pressure monitoring. Pressure transducer kit includes: -- transducer -- infusion set -- pressure monitoring line -- stopcock etc 20pcs/carton
JD168 series are low range differential pressure transducers and transmitters with NEMA4 (IP-65) rated aluminum. They are very rugged and very reliable, good for many industrial applications. The patented stainless steel sensor provides good corrosion resistance, excellent performance and long-term stability. Our unique production setup can also make special pressure range (e. G. -0.5WC to +3.5WC) to meet special applications. Features: Up to 15 PSI overpressure on all ranges Wrong-wiring full protection Pressure range as low as 10pa only Application: Power plant air flowmonitor and controw Clean room and fime hood control Duct static pressure control Draft control HVAC and VAV control Furnance air flow control. Shocking-proof package.
Sound output (at 10 cm) dBA: Min. 70 (3Vp-p, 4000Hz, Square Wave) Max. Input Voltage Vp-p: 25 Max. Current Consumption mA: 1.0 Capacitance ( at 120 Hz ) pF: 14000 pF ± 30 % Operating Temperature º C: -20 ~ +80 Storage Temperature º C: -30 ~ +85 Terminal : SMD Housing Material / Color : LCP/Black Weight g: 1.
Operating Voltage V: 4 ~ 6 Rated Voltage V: 5 Rated Current mA: Max. 80 Coil DC Resistance : 40 ± 5 Sound output ( at 10 cm ) dBA: Min. 90 Rated Frequency Hz: 2700 Operating Temperature º C: -20 ~ +70 Storage Temperature º C: -30 ~ +85 Terminal : SMD Housing Material / Color: LCP / Black Weight g: 0.9.
We are the professional fish finder transducer manufacturer in China a)Cable:8-20m. b)Frequence:50KHz,200KHz,50/200KHz c)Power:300-1000w d)Material:Bronze e)Connector: Pin3-Pin10 f)Compatible:Furuno,Garmin,Raymarine,Navman,Hondex,Humminbird,Koden etc. 26*14*9cm.
Main characteristics: High efficiency: with high mechanical quality, it can achieve high transfer efficiency between electrical energy and acoustic energy when working at the point of resonance frequency. Large amplitude: after optimal designed by computer, the speed of vibration becomes high and the amplitude of front plate becomes large. High power: under the action of the prestressed bolts , piezoelectric ceramic energy reaches to the utmost. Good heat-resistance : of small resonance impedance, little quantity of heat, can be used in a wide range of temperature with long life and high reliability.
Et-500 electropneumatic transducer Input electrical current:4-20ma, 0-10v Output pressure:20-100kpa Et-500 is electropneumatic transducer equipment, it can decrease supply pressure to produce output pressre which is effectively proportional to input electric signal. Supply pressure range:125kpaí½1000kpa.With bulk augmenter supply big flow (20.4 m3/h). Features: Flow rate: 7.6m3/h when supply pressure is 175kpa 20.0m3/h when supply pressure is 700kpa Min/max. Supply pressure: Minimum-3psig(21kpa) above maximum output Maximum-100psig(700kpa) Sensitivity:
We have many kinds of connector types, such as edwards, utah, argon, philips, ICU/ medex/ elcam/ abbot/ hospira/ biometrix, ace, bd etc, and also we produce monitor cable which have different connector. 30pcs per box
1, high mechanical quality and excellent electro-acoustic conversion efficiency, providing a high ouput amplitude. 2, having steady output amplitude even the load markedly changed. 3, extended using temperature, ensuring god amplitude linearity. 4, ensuring high conversion efficiency
Pcui immersible ultrasonic transducer pack can be used together with our "pcug" - series pulse sweep frequency generator to perform an ultrasonic cleaning equipment. It internally equipped with high power, durable blt transducers with hard chrome plating sonic surface on stainless steel housing to provide a ultra-long life feature. The size and power of transducer pack can be custom made. Generally, the output power can be from 600w to 3600w with one or more frequency combination. The operating frequency can be offered from 25khz to 130khz.
Ultrasonic cleaning transducer Ultrasonic cleaning transducers features: 1 low resonance impedance 2 high mechanical quality factors 3 high transforming efficiency from electrical energy to mechanical energy 4 low calorific capacity 5 good consistencies of frequency and static capacitance
Product Introduction: SAND PT4XX6 series pressure transducers are ideal for the measurement of melt pressure in extrusion processes at temperatures up to 400 . This series are produced with special materials and alloyed elastic diaphragm together with delicate processing and debugging. The main characteristics are high accuracy and small zero and span shifts caused by changes in process temperatures Performance Parameters: Pressure Range: 0 ~ 5 MPA ~ 150 MPA ( 0 ~ 750psi ~ 20000psi ); Accuracy: ±0.5% FS; Power: 10VDC ( 6 ~ 12 V DC ); Output Signal: 3.33mV/V (Default), 3.0mV/V(Optional) etc. Probe Heat Resistance: PT4516 Series: 300°C; PT4616 and PT4626 Series: 400°C; Temperature Drift: =500M/500VDC; Mechanical Connections: 1/2"-20UNF, M10x1.5, M12x1.5, M14x1.5, M18x1.5, M22x1.5 etc. (Optional) Electrical Connections: 6PIN (SD02106P/SD02106S); Thermometric Config: Thermocouple: E, J, K, S type etc.; (PT4626 Series Optional) Thermal Resistance: Pt100 etc. (PT4626 Series Optional) Features: * Anticorrosive wear-resisting coating: apply to high concentrations of rough media pressure measurement, can improve the service life of 3 to 5 times (optional); * Special requirement can make to order, delivery date 7 ~ 15 working days; * Optional supporting intelligent digital pressure meter: PS1016-43x series, PS4810-43x series, PS4812-43x series and PS9016-43x series. Order Format: Example1: PT4516-350bar-M18-150-3.33mV/V Note: Product design Model "PT4516". Function code "Null" stands for melt pressure transducer. Coating code "Null" stands for without coating . Pressure range: 0 ~ 350bar. Thread size : M18 * 1.5. Rigid stem length:150mm . Pressure output signal: 3.33mV/V.
for the measurement of electrical variables in heavy current power system RISH Ducer M40 (Fig. 1) is a programmable transducer with a RS 485 bus interface (MODBUS ). It supervises several variables of an electrical power system simultaneously and generates 4 proportional analogue output signals. The RS 485 interface enables the user to determine the number of variables to be supervised (up to the maximum available). The levels of all internal counters that have been configured (max. 4) can also viewed. Provision is made for programming the RISH Ducer M40 via the bus. A standard EIA 485 interface can be used, but there is no dummy load resistor for the bus. The transducers are also equipped with an RS 232 serial interface to which a PC with the corresponding software can be connected for programming or accessing and executing useful ancillary functions. This interface is needed for bus operation to configure the device address, the Baud rate and possibly increasing the telegram waiting time (if the master is too slow) defined in the MODBUS protocol. The usual methods of connection, the types of measured variables, their ratings, the transfer characteristic for each output and the type of internal energy metering are the main parameters that can be programmed. The ancillary functions include a power system check, provision for displaying the measured variably on a PC monitor, the simulation of the outputs for test purposes and a facility for printing nameplates. The transducer fulfils all the essential requirements and regulations concerning electromagnetic compatibility(EMC) and safety (IEC 1010 resp. EN 61 010). It was developed and is manufactured and tested in strict accordance with the quality assurance standard ISO 9001. nSimultaneous measurement of several variables of a heavycurrent power system / Full supervision of an asymmetrically loaded four-wire power system, rated current 1 to 6 A, rated voltage 57 to 400 V (phase to neutral) or 100 to 693 V (phase-ton phase) nFor all heavy-current power system variables n4 analogue outputs nInput voltage up to 693 V (phase-to-phase) nUniversal analogue outputs (programmable) High accuracy: U/I 0.2% and P 0.25% (under reference nconditions) 4 integrated energy meters, storage every each 203 s, storage nfor: 20 years Windows software with password protection for programming, data analysis, power system status simulation, acquisition of nmeter data and making settings DC-,AC-power pack with wide power supply tolerance / nuniversal Provision for either snapping the transducer onto top-hat rails or securing it with screws to a wall or panel
Product Introduction: PT4XX6 series pressure transducers are ideal for the measurement of melt pressure in extrusion processes at temperatures up to 400 . This series are produced with special materials and alloyed elastic diaphragm together with delicate processing and debugging. The main characteristics are high accuracy and small zero and span shifts caused by changes in process temperatures Performance Parameters: Pressure Range: 0 ~ 5MPA ~ 150 MPA ( 0 ~ 750psi ~ 20000psi ); Accuracy: ±0.5% FS; Power: 10VDC ( 6 ~ 12 V DC ); Output Signal: 3.33mV/V (Default), 3.0mV/V(Optional) etc. Probe Heat Resistance: PT4516 Series: 300°C; PT4616 and PT4626 Series: 400°C; Temperature Drift: =500MΩ/500VDC Mechanical Connections: 1/2"-20UNF, M10x1.5, M12x1.5, M14x1.5, M18x1.5, M22x1.5 etc. (Optional) Electrical Connections: 6PIN (SD02106P/SD02106S) Thermometric Config: Thermocouple: E, J, K, S type etc.; (PT4626 Series Optional) Thermal Resistance: Pt100 etc. (PT4626 Series Optional) Features: * Anticorrosive wear-resisting coating: apply to high concentrations of rough media pressure measurement, can improve the service life of 3 to 5 times (optional); * Special requirement can make to order, delivery date 7 ~ 15 working days; * Optional supporting intelligent digital pressure meter: Order Format: Example1: PT4516-350bar-M18-150-3.0mV/V Note: Product design Model "PT4516". Function code "Null" stands for melt pressure transducer. Coating code "Null" stands for without coating . Pressure range: 0 ~ 350bar. Thread size : M18 * 1.5. Rigid stem length:150mm . Pressure output signal: 3.0mV/V. Example2: PT4616-50MPa-1/2"-20-150/470-3.33mV/V Note: Product design Model "PT4616". Function code "Null" stands for melt pressure transducer. Coating code "Null" stands for without coating . Pressure range: 0 ~ 50MPa. Thread size : 1/2"-20UNF . Rigid /Flexible length:150mm/470mm . Pressure output signal: 3.33mV/V. Example3: PT4626-50MPa-M14-150/470-J-3.33mV/V Note: Product design Model "PT4626". Function code "Null" stands for melt pressure transducer. Coating code "Null" stands for without coating . Pressure range: 0 ~ 50MPa. Thread size : M14*1.5 . Rigid /Flexible length:150mm/470mm . Thermometric config: J type thermocouple temperature sensor . Pressure output signal: 3.33mV/V.
Nominal Current(RMS):10/25/50/75A Vout@Ipn:2.500+_0.625V Measuring Range:0~+_150A Supply Voltage DC:+5V Accurancy@Ipn,+25degree Celsius:less than +_0.5% Mounting(mm):8.2 in diameter
Nominal Current(RMS):50/100/200/300/400/600A Vout@Ipn:+_4.000V Measuring Range:0~+_900A Supply Voltage DC:+_12-15 Accurancy@Ipn,+25degree Celsius:less than +_1.0% Mounting(mm):10.5*20.5