Compact, space saving design No special tools are needed for assembly Reduce space for storage and transportation High flexibility Designed according to customer needs Dimensions : â?? Height from 300 mm up to 1200 mm â?? Width from 300 mm up to 1000 mm â?? Depth from 200 mm up to 300 mm Protection degree up to IP 65 Can be equipped cable compartment Rated current up to 630A Design and assembled according to IEC 439-1 All routine tests are applied Polyester powder RAL 7032 or 7035 As Reqest Incoming and outgoing from top or bottom Can be recessed Frame Must Be added or wall mounted Applications : Main & outgoing switchboards Motor Starter Load Center up to 72 Lines Available in stainless steel as per Request
General KYN28A-12 type metalclad withdrawable switchgear is a complete set of three phase AC indoor device and applicable to the singlebusbar and single busbar section power system of which the rated voltage is 3.6 to 12 kV,the reated frequency is 50/60Hz,Having perfect"five prevention"function,Used for power reception and power distribution,the device is mainly used in power plant,transformer substation,industrial and mining enterprises and high building,Having the function of controlling,protecting and monitoring the circuit. Standards: - KYN28A-12 switchgear meets the following domestic and international standards: IEC62271-200, GB3906, GB/T11022, DL/T404, etc.. Working condition: Normal working condition Ambient temperature: - Maximum temperature +40 C - Average value is no more than +35 C - Minimum temperature -15 C Ambient humidity - Daily average relative humidity of 95% and below - Average relative humidity of 90% and below - Maximum altitude of 1000 meters of the place of installation - Earthquake intensity is not more than 8 degrees, there is no fire, explosion danger, serious pollution, chemical corrosion and violent vibration. Technical data:
Main functions: 1. Decrease starting current. Utilizing soft start as the most general application starting mode, the motor is given an initial voltage setting, from the initial voltage level; the output voltage to the motor is steplessly increased to the rated full voltage in the pre-setting ramp time. The starting current of the motor is limited in 2 times of the rated working current, while the conventional full voltage starting current is 5 or 6 times of the rated working current. The limited soft starting current can decrease the insulation damage to the motor & the cable and avoid the problem of mechanical and electric pressure as well as lengthen mechanical life of the ESP-unit and reduce maintenance. 2. Eliminate operating over-voltage. Utilizing soft stop as the most general application stop mode, the output voltage to the motor is steplessly decreased from the full voltage to the point where the load torque is greater than the developed motor torque, this can eliminate the 3 or 4 times operating over-voltage occurred with conventional coast-to-rest stop or unexpected power-off. The destruction of the 3 or 4 times operating over-voltage is always a deathblow especially to the worn-out and low-insulating motor. 3. Surge voltage absorption equipment The built-in resistance-capacitance surge voltage absorption equipment can effectively reduce the destruction of the opposing electromotive force occurred with coast-to-rest stop or unexpected power-off, so as to protect the motor. 4. By-pass contactor If the Controller senses that the soft starter itself has a malfunction, the output voltage can be switched to full voltage (Power-Frequency) to ensure the continuous running by the built-in bypass contactor. 5. Auto-startup under load time delay When mechanical unit soft stop under load, if user turn on the auto-startup when under load, it will soft start automatically by the time delay setting. 6. Consummate protection It can protect the mechanical unit not only overload, under load, short circuit, phase loss, three phase unbalance, but also over voltage and under voltage protection, when this mode is turned on, when the working voltage is higher or lower than the setup value it can stop to protect the mechanical unit. 7. Backlit LCD display and programming keypad. The human interface modules, a display panel and a Switchboard, can be used to program and display the following technical parameters: * Three-phase current *Three-phase voltage * Active Power *Reactive Power * Apparent Power *Power factor *175 pieces of diagnostic and running data *Power Consumption. 8. Default Phase and Phase discrimination Protection When the phase order is default or connect wrong, the unit would not start and clue on the LCD screen. 9. Grounding automatic-alarming function. 10. Display the online detection of unit insulated resistance. (*as usersf+ requirement) 11. Communication and remote control. The Soft Controller can be configured to communicate via radio (and GSM or GPRS) or wire-line to computer in remote control center. The controller supports ModBus protocol. (*as usersf+ requirement) All in one sentence, The QYRK serial Soft-Start Switchboard has very important meaning for lengthen the mechanical unit life, reduce maintenance and the ESP colligate cost. Normal ESP switchboard doesn't have these features.
GANZ measuring instruments are made according to the EN 60051;EN 61010-1, and DIN 43780 standards. The accuracy of the instruments is idnicated on the detailed data sheets. (0,5;1;1,5;2,5;3%). The dimensions of the cases and the cut-outs comply with the standard DIN 43700. The instrument cases are made of inflammable plastic according UL 94 V-1 or steel plate. See at the detailed technical data sheet at our website:www.ganzinst.hu.
The inflatable ring network cabinet is suitable for 12kV power system, which is mainly used for power supply of ring network, automatic isolation of fault area and line segment in distribution network.Only the upper power distribution automation terminal equipment (FTU/RTU) and communication device are equipped in the ring network cabinet to communicate with the control center of the power distribution automation system, and it can measure the voltage and current of the line and monitor the working state of each switch. The ring network cabinet seals all switch equipment in a closed stainless steel box filled with SF6, and there is no exposed live body outside. It is a fully enclosed and fully insulated switch equipment, which is not affected by the external environment and runs safely and reliably.The ring network cabinet is divided into straight through cabinet, circuit breaker cabinet, load switch cabinet, combination electrical cabinet, contact switch cabinet, metering cabinet and other standard units can be flexibly combined to achieve multiple schemes.
Electrical switchboards/panels. As per customer specifications.
Style no: KYN ANTI-corrosion high voltage switch cabinet 1)main special feature: 1anti-corrosion aluminized and galvanized steel cabinet, can be used in complex working situation 2with flexible hardcart, easy for operation and maintenance 3full safety protection for human and electric grid 4: multi loope distribution way 2)general Kyn28 is a complete set of indoor equipment for power distribution / receiving , protecting and supervisng the circuit. Rated voltage Kv3.Kv to24kv Frequency Hz50hz, 60hz Rated current of breaker A630, 1250, 1600, 2500, 3150 Rated current of switch gear630, 1250, 1600, 2500, 3150 Rated short time withstand currentKa16, 20, 25, 31.5, 40 Peak value withstand curent40, 50, 63, 80, 100 3)features 1: strict protection step to ensure personal safety 2: the cable room can be installed as many as 6 to 9 single-core cables 3: operation and testing positions will be established for the handcart, and both positions are equipped with safe and reliable positioning device and display device 4: the enclosure is completely assembled from aluminized and galvanized steel plate, which are machined and bent by machine tool and then bolted. 5: it has high mechanical strength and its neatness and beauty is ensured. 6: the switchboard door is sprayed with plastic, also has strong capacity of impact resistance and corrosion protection. 7: the primary switch may be provided with vd4 vacuum circuit breaker and c3 series of fixed type load switch from abb, various domestic vacuum circuit breakers (such as vs1, vh1, vk, zn28) may also be provided in lieu of the same foreign products. 8: front door is installed with a observation window to check the operating state of the components inside the room. Wooden case.
Style no: KYN anti-corrosion high voltage switch cabinet 1) Main special feature: 1. Anti-corrosion aluminized and galvanized steel cabinet, can be used in complex working situation 2. With flexible hardcart, easy for operation and maintenance 3. Full safety protection for human and electric grid 4. Multi loope distribution way 2) General KYN28-12 is a complete set of indoor equipment for power distribution / receiving , protecting and supervisng the circuit. Rated voltage KV 3.KV to12KV Frequency Hz 50Hz,60Hz Rated current of breaker A 630, 1250,1600,2500,3150 Rated current of switch gear 630, 1250,1600,2500,3150 Rated short time withstand current KA 16,20,25,31.5,40 peak value withstand curent 40,50,63,80,100 3) Features 1: STRICT protection step to ensure personal safety 2: The cable room can be installed as many as 9 single-core cables 3: Operation and testing positions will be established for the handcart, and both positions are equipped with safe and reliable positioning device and display device 4: The enclosure is completely assembled from aluminized and galvanized steel plate, which are machined and bent by machine tool and then bolted. 5: It has high mechanical strength and its neatness and beauty is ensured. 6: The switchboard door is sprayed with plastic, also has strong capacity of impact resistance and corrosion protection. 7: The primary switch may be provided with VD4 vacuum circuit breaker and C3 series of fixed type load switch from ABB, various domestic vacuum circuit breakers (such as VS1, VH1, VK, ZN28) may also be provided in lieu of the same foreign products. 8: Front door is installed with a observation window to check the operating state of the components inside the room 4) Conformity standard: GB3906,GB/T11022, IEC60298, DL/T404. One piece per wooden case.
Switchboard.
Electrical switches & controls, other electrical equipment, other electrical and electronic goods.Manufacturer
Heavy machinery, conveyor belt, machinery conveyor systems, electric motors.
We are works a manufacturing electrical switchboard in indonesia and so we can install electrical switchboard that. We move on to in electrical & instrumentation installation for factory & industry. Move on as your order.
Electrical Matting The insulating matting is used when operating switchboards, live LV-HV switchgear, substations, transformers and electrical workstations, insulating rubber matting protects workers against electrical shock by absorbing the power that can result from a short circuit or other electrical leak.
Panel space heaters Technical specifications: Insulation level : 2.0 kv for 1 minute Rating : 30 to 300 watts
Switchboard sheet.
The small-space fire extinguishing tool family is designed to respond to fires that occur in everyday life and industrial sites Prepared products. Simple installation method makes it easy for anyone to use. Product List: White Lease - Application of temperature-responsive automatic injection nozzle system To suppress the source of fire diffusion based on initial fire suppression - Mechanical, electrical wiring, no additional equipment ##Power-operated fire suppression small space fire extinguishing equipment White-less patch type | Fireless - Simple installation in small spaces such as distribution boards, switchboards, engine rooms, outlets and plugs - In response to temperature, the shell of the microcapsule bursts, and a special digestive agent in the capsule Sprayed to automatically extinguish fire in golden time
Mainly used in the low voltage distribution switchboard to control and protect power distribution systerm. Its technical index reaches the international advanced standard of that kind of products in 1990s and conforms to criteria for low voltage breaker in iec60947-2
Electrical component switchboard.
Low voltage switchboards (electrical panels)..
Cable tray, switchgear, switchboard, HV circuit breaker.