As a leading manufacturer and supplier in this domain, we are offering a high quality compact substation which has compact and sturdy design to save space. It is pre-fabricated secondary sub station containing, distribution transformer, medium voltage switch gear, low voltage switch board, connections and associated equipments in a compact unit. All components are housed an enclosure, which protects the equipment from environment hazards and unauthorised access. The electrical equipment is cooled by natural ventilation through openings in the sub station. It is designed in accordance with IEC-61330 standards. The Compact Substation is computerised with suitable medium voltage, low voltage sections and transformer section with separate doors for each compartment.
170mv substation equipment International standard
LMZ designs the best proper Mobile Substation by analyzing customer requirements, site and transportation conditions. SETAS Mobile Substations are used for military camps, industrial facilities, distribution networks, emergency power demands and additional power requests. Mobile Substation General Specifications: HV switching equipments can be gas ORA IR insulated Trailer / Platform / Wagon / Vessel type applications Up to IP 56 Protection Class Entire substation can be deliver being ready to use in a SCADA system Shorter manufacturing time compare to fixed type. Ideal solution for emergency power demand, temporary services and new services Production is made according to IEC 62271-202, 200, standards, different standards can also be applied on demand.
Engaging in tower manufacturing for more than a decade, our company has longtime experience in the design, manufacture and installment of steel tower mast structure. Main products include all kinds of iron towers and similar steel structures widely used in the fields like power transmission, substations, telecommunication, microwave-communication, radio/TV broadcasting, mapping, watchtower etc.
Phase - Three Phase Material -MS Brand -Rukmani Rustproof -Yes Country of Origin -Made in India Finish - Hot Dip Galvanized Range - Upto 1200 KV With A Dedicated Team Of Engineers, Supervisors & Production Workers Our Manufacturing Facility Approved By Top Industrial Utilities Like Powergrid, Ntpc, Adani, Dvc, Nhpc, State Electricity Boards â?? Power Generation / Power Transmission / Power Distribution Divisions Like Optcl, Aptransco, Apgenco, Jusnl, Tantransco, Mpptcl, Msetcl, Mahagenco, Getco Etc. For Supply Of Substation Structures (Up To 1200kv) As Per The Approved Proto Corrected & Shop Floor Drawings.
T-connector, Terminal connector, Busbar fittings Material: Aluminium alloy wide range of bus supports and compression connectors for substations and other utility installations. Our components are created in accordance with IEC and GB specifications, ensuring quality, longevity, safety and performance.
Supply & Installation of Electrical Substation
Substation structures like transformers, lightning arrestor, beams etc are always out in the open surroundings and they can easily get corroded with wear and tear. In order to protect them galvanization is absolutely essential. We hold the expertise in galvanizing all kinds of substation structures at minimal possible costs. We finish all the work on promised deadlines and quality standards are purely top notch.Our products being used by Power Plants, Cooling Towers Manufacturers, Railways, Refinery Projects, Fertilizer Industries, Cement Factories, Petrochemical Projects and Large Scale of Industrial Units.
Switchgears LV, MV, HV Compact Substations Switch board Cable Trays
NF801 is the new generation of digital relay tester. This digital relay tester is equipped with 8 optical ports, and its powerful data processing capability can achieve the full functional test of the IEC61850 devices. Support GPS\ IRIG-B\ IEEE 1588 synchronization, it makes the substation internal debugging and substation to substation combine debugging available. NF801 integrated some unique functions including: the abnormal SV\GOOSE simulation, virtual terminal test, the optical power testing and so on. Features 8 fiber optical ports for:Receiving and sending IEC61850-9-2 format SV and GOOSE message;Receiving and sending IEE1588 message;Measuring received fiber optical power Provide flexibility to configure both SV (IEC61850-9-2) and GOOSE ports independently. Each port can be configured as Receive and Send at the same time or it can be configured as Receive or Send. Can check the GOOSE communication link SV, GOOSE configure message can be saved and recall repeatedly With the IEEE1588 synchronization function, deviation of the time is less than ±80ns With GPS, IRIG-B code synchronization interface
ZBW Type Prefabricated Substation,mobile transformer substation,distribution transformer substation,power substation transformer ZBW Type Prefabricated Substation ZBW packaged substation, also known as prefabricated substation. It meet GB17467-1998 high and low voltage prefabricated substation and IEC1330 standards etc. As a new type of power supply and distribution device, has more advantages than traditional civil substation. Product Description ZBW packaged substation, also known as prefabricated substation. It meet GB17467-1998 high and low voltage prefabricated substation and IEC1330 standards etc. As a new type of power supply and distribution device, has more advantages than traditional civil substation. Such as smaller size, smaller floor area, compact structure, flexible movement, which greatly reduce period and area for construction in site, also the construction cost. Meanwhile, prefabricated substation is easy to be installed at site , can realize rapid power supply, almost maintenance free. Most particularly, it is placed at load center so that reduce power loss effectively to improve power quality, enhance the reliability of power supply and also is significant for distribution network transformation. This substation fulfills the functions such as transformation of energy, distribution, transmission, metering, compensation, system control, protection and communication. The ZBW prefabricated substation is composed by the high-voltage switchgear, low-voltage distribution panel, distribution transformer and enclosure. The high-voltage switchgear adopts air load switch and the transformer is dry-type or oil immersed type. The substation adopts good ventilation structure with elegant appearance and good heat-insulating performance. The temperature rise of the compartments caused by the outdoor solar radiation can be reduced to within the lowest limits on account of the upper and lower ventilation windows. The forced ventilation device and the temperature auto-controlled device should be installed in the substation. The systems of control, protection, live display and the lighting are equipped in each separate unit. Product Features
NF801 is the new generation of digital relay tester. This digital relay tester is equipped with 8 optical ports, and its powerful data processing capability can achieve the full functional test of the IEC61850 devices. Support GPS\ IRIG-B\ IEEE 1588 synchronization, it makes the substation internal debugging and substation to substation combine debugging available. NF801 integrated some unique functions including: the abnormal SV\GOOSE simulation, virtual terminal test, the optical power testing and so on. Features 8 fiber optical ports for:Receiving and sending IEC61850-9-2 format SV and GOOSE message;Receiving and sending IEE1588 message;Measuring received fiber optical power Provide flexibility to configure both SV (IEC61850-9-2) and GOOSE ports independently. Each port can be configured as Receive and Send at the same time or it can be configured as Receive or Send. Can check the GOOSE communication link SV, GOOSE configure message can be saved and recall repeatedly With the IEEE1588 synchronization function, deviation of the time is less than ±80ns With GPS, IRIG-B code synchronization interface
NF802 is the new generation of digital relay test equipment with local control. This digital relay tester is equipped with 8 optical ports, and its powerful data processing capability can achieve the full functional test of the IEC61850 devices. Support GPS\ IRIG-B\ IEEE 1588 synchronization, it makes the substation internal debugging and substation to substation combine debugging available. NF802 integrated some unique functions including: the abnormal SVGOOSE simulation, virtual terminal test, the optical power testing and so on Features 8 fiber optical ports for:Receiving and sending IEC61850-9-2 format SV and GOOSE message;Receiving and sending IEE1588 message;Measuring received fiber optical power Provide flexibility to configure both SV (IEC61850-9-2) and GOOSE ports independently. Local control with quick control buttons Each port can be configured as Receive and Send at the same time or it can be configured as Receive or Send. Can check the GOOSE communication link SV, GOOSE configure message can be saved and recall repeatedly With the IEEE1588 synchronization function, deviation of the time is less than ±80ns With GPS, IRIG-B code synchronization interface.
PNS630 portable analyzer was designed for smart substation maintenance. IEC61850-8-1(Goose),IEC61850-92, IEC60044-7/8 msssage can be monitored and analyzed, digital relay test function also equipped. SMV GOOSE message numerical and status analysis were realized and dispalyed visually by its numerical analyzing function. Features 1) Support IEC 61850-9-2, IEC 60044-7/8 (FT3), GOOSE, IRIG-B and IEEE1588 standards. 2) Support SCD, ICD, CID files analysis to get sampling value, sampling channel and GOOSE signal configuration. 3) Support SCD displayed in graphics. 4) Support SMV ang GOOSE monitor, and record the abnormal messages. 5) Support IEC60044-7/8 (FT3) receving and sending. The baud rates 2.5Mbps, 5Mbps, 10Mbps is available. 6) Support IEC 61850-9-2/9-2LE receiving and sending. ASDU 1-8 is available. 7) Support message monitor and record (PCAP format) for analysis. 8) Support network load analysis. 9) Support phase check. 10) Support IRIG-B and IEEE 1588 synchronization to provide time synchronization and clock source. 11) Simulate MU to output IEC61850-9-2, IEC 60044-7/8 to test digital relays. 12) Support IED time delay and SOE test. 13) Support MU time delay test, synchronization and time test. 14) Support to output messages in different flow. 15) Support SMV in different status in maximum 10. 16) Support DC testing to test digital voltage, CT and PT�??s polarity. 17) Support dBm test within -31dbm~-14dbm at wavelength 1310nm. 18) Large LCD screen to operate. 19) Chargeable battery for continuous working 6 hours above.
1)Shape of section;polygonal, round; 2)Slip joint or flang connect; 3)Voltage grade;10-220KV ; 4)Deal: Hot dip galvanization 5)Material: hot rolled coil steel (Q235, Q345 or as lients requested) 6)Packing: Plastic bulble, mat & straw bale at the top and bottom or as clients required Advantage; Light weight; Easy install; Compactness; Reduced visual intrusion; Reduced right of way; Reduced land occupancy; Price competitive or lower cost than wood, concrete and sometimes lattice tower; Environmental inert: non toxic, no disposal cost, fully recyclable; Compatible with most standard hardware and banding; Aesthetically pleasing; Reduced transportation cost; Minimal maintenance and inspection cost;
Qingdao Wuxiao electric power substation framework is the steel framework for electric power transmission and transformation.We manufacture them with complicated technology and adopted sophisticated production line. Now we sell them widely all over the world. Availability size: Based on the customers requirements. Material:All the steel are used the noted Chinese steel plant products or based on the customer's specific requirements or product them according to our Chinese national standard. Color: Silver white or Based on the customers requirements. Package: wrapped with felt cloth or rubber mat and fix them by iron wire in case of collision or bump Terms of Payment: L/C,T/T Capacity: 40,000tons/year Delivery Time: one month or based on the customer's need Certification: We also supply Factory accept test,Warranty certification, Certificate of product quality, Certification of Quality Management System
UPS with nickel cadmium battery for power substation; UPS with lithium battery for power substation, telecom; IP55 outdoor UPS with water proof, work for -45C degree to +60C degree environment for railway, telecom, power substation; DC UPS with 48V/110V/125V/220VDC for power substations 110V/125V/220V battery chargers for power substations, plant, lithium battery, electricity, navy 110V/125V/220V inverters for power substations, power plant,
48V/110V/220V/10A-5000A thyristor battery charger, IGBT battery charger, phase-controlled battery charger, modular battery charger, rack mount battery chargers are widely used for power substations, plants, electric car, lithium batteries, capacitors, etc.
1. Function: AC sampling device and sampling RTU (Remote Terminal Unit) calirbation 1) AC/DC analog value input measurement 2) state variables input measurement 3) remote control execution testing 4) remote regulation function testing 5) digital value input testing 6) impulse input testing 2. AC Power source It can output AC voltage AC current accuracy 0.05 class can provide standards of AC/DC voltage/current power phase power factor frequency energy. Output method and output electric quantity can be set arbitrarily 3. Data management It can save search browse print or delete RTU testing data. Calibrated parameters can be saved permanently
1. Function: AC sampling device and sampling RTU (Remote Terminal Unit) calirbation 1) AC/DC analog value input measurement 2) state variables input measurement 3) remote control execution testing 4) remote regulation function testing 5) digital value input testing 6) impulse input testing 2. AC Power source It can output AC voltage AC current accuracy 0.05 class can provide standards of AC/DC voltage/current power phase power factor frequency energy. Output method and output electric quantity can be set arbitrarily 3. Data management It can save search browse print or delete RTU testing data. Calibrated parameters can be saved permanently