Supports Measuring Values, Output Tests, and Adaptations on control modules using the new UDS/ODX/ASAM protocol. Adds new UDS addresses and updated ODX data for 2010 models. Includes support for TP1.6 protocol which is required for the 6J Ibiza and speeds up access on many modules in other models. The Select Control Module screen now shows "Installed Modules" rather than "Common Modules" if the car being worked on is new enough to have a proper CAN Gateway. Modified SRI Screen to show more info and force user to select a job before proceeding. Adds drop-box function selection in Basic Settings and Adaptation. Reads Mileage stored in many EDC16 ECUs. New CODES file, now with over 13, 000 fault code and measuring value texts. New USB drivers for enhanced PC compatibility and stability. New firmware for HEX interfaces required for compatibility with 6J Ibiza Updated Label files; better documentation for new and existing models. Compared with the 812, the 908 has its biggest advantage. It lies in that the 908 can match Airbags under the protocol of UDS while the 812 can only read code, erase code and do coding, and it cannot match airbags. Pls check the comparence in the following pictures. The icons of 908 are activated while the ones of 812 are not. The new models that the VW launches now or in the future, such as New Bora and Lavida, will all use UDS protocol. Besides, the VAS5054 in the market nearly doesn't support UDS protocol.
1, Use: Aluminum wire and ACSRs structures are simple. They are easy to set up and maintenance. The cost is low in building the lines. The transmission capacity is large. They are also convenient to cross special geographical conditions, such as rivers, valleys and so on. So the products are applied for various voltage levels of overhead transmission and distribution lines. 2, Model Model Name cross sectional area LJ aluminum wire 16-500 LGJ ACSR 10-240 GB/T1179-1999 "Round wire concentric lay, stranded conductors" standard is equivalent to IEC61089-1991 standard. According to user needs. Our company can produce the aluminum wire and ACSR on the basis of ASTM, DIN, BS and other standards. Note: the products model and code in GB1179-83 of the new and old standard still has a large number of users and market, it can be used as non-standard£¨or users special needs£© when ordering the products. 3, material standards: Aluminum wire and ASCR with a hard steel core execute GB/T17048 (identical with IEC60889 standard). ACSR with galvanized steel execute IEC60888 standards. According to users needs, we can produce the production on the basis of the user's material standards and requirements. 4, product performance: the electrical properties of aluminum wire and ACSR should be showed as the resistance at 20 ¡æ. Hard aluminum wire's resistance is not greater than the international standard value 0.028264¦¸.mm2 / m. ACSR has three intensity levels: general intensity level ACSR, high strength ACSR and extra high strength grade level ACSR. 5, product maintenance: the product should avoid squeezing and bumps during handling and transportation. Cables should not be laid flat during the transportation and storage. Product should take moisture measures during storage.
Types : 1) ladder straight run 2) ladder inward bend 3) ladder outward bend 4) ladder bolted type. Strength - light, medium & heavy duty Raw material - mild steel is 1079, pre-galvanized sheet, stainless steel & aluminum Width - 150 mm to 1200 mm Side channel height - 50 mm to 150 mm Run width - 30 mm to 50 mm Run height - 10 mm to 20 mm Run c to c - 250 mm / 300 mm Thickness - 1.6 mm to 3 mm Length - 2500 mm / 3000 mm & 2444 mm (for aluminum) Finish - mild steel: self finish, pre-galvanizing (mill finish), hot dip galvanizing as per I.S. 2629 / 4759, bs 729, astm 123, painted (red oxide, painted & powder coated) Finish - stainless steel: self finish & mirror finish Finish aluminum: self finish & anodized finish. Loose and safe.
Perforated type cable tray Types : 1) perforated straight channel 2) perforated inward bend 3) perforated outward bend 4) perforated with reinforcement. Strength - light, medium & heavy duty Raw material - mild steel is 1079, pre-galvanized sheet, stainless steel & aluminum Width - 50 mm to 1200 mm Height - 10 mm to 100 mm Thickness - 1.2 mm to 3 mm Length - 2500 mm / 3000 mm & 2444 mm (for Aluminum) Finish - mild steel: self finish, pre-galvanizing (mill finish), hot dip galvanizing as per I.S. 2629 / 4759, bs 729, astm 123, painted (red oxide, painted & powder coated) Finish - stainless steel: self finish & mirror finish Finish aluminum: self finish & anodized finish. Loose and safe packing.
1. Fibre optic patch cord LC/UPC-SC/UPC Singlemode Duplex 2. Various kinds of connectors available, LC, SC.ST, FC, MTRJ, E-2000, MTP 3.Optional Outer Jacket, PVC,LSOH 4.APC Polish Available 5.Custom length, metres, feet accepted. depends on the lengh and quantity.
ABC Cable 1) Standard: IEC60502/BS 2627 2) Voltage: 0.6/1kV 3) Certificate: ISO, CCC 4) MOQ: 3KM ABC Cable Aerial bundled cable Standard and application scope: This product is produced in accordance with the standard of IEC60502/BS 2627. The products,Cu core or Al core XLPE or HDPE aerial insulated electric power cable,may be used for the fields where the A.C.rated voltage U(Um) is 0.6/1kV. Using feature: 1) The max. long-term operating temperature of cable conductor(cable having supporting structure): a) XLPE insulation :90¡ãC b) HDPE insulated 75¡ãC 2) When short circuit (the Max. lasting time is not over 5 seconds), the Max.temperature of the cabl: a)XLPE insulated: 250¡ãC b)HDPE insulated 150¡ãC 3) When laying, the temperature should not be lower than -20oC; 4) The permitted bend radius should not be less than the diameter of cylinder that had been used for the bend testing. 5) Cables installed in air; 6) Ambient temperature:40oC 7) Intensity of solar radiation:1000w/m2.
Structure: Solid bare copper conductor, pe insulation, center cross skeleton, aluminum foil screen, pvc/pe /lsoh sheathed. Standard: Europe celenec en 50173/50167 Usa eia/tia568b International iso/iec 11801/61156 China yd/t 1019-2001. According to client request.
sell coaxial cable with messenger,messenger wire CCS + FPE + Al foil + braiding + jacket£¬diameter: 1.00, 1.02, 1.25, 1.66,2.15, 2.77mm available 2.dielectric: foamed PE, solid PE available 3.shield: AL foil (bonded/ unbonded), copperized AL foil (bonded/ unbonded) 4.braiding wire: Cu, Al-Mg, TC available braiding wire diameter: 0.12mm, 0.15mm, 0.16mm available braiding net number: 32, 48, 64, 96, 128, etc braiding coverage: 30-95% 5.jacket: PVC, PE color: white, black etc. 6.OEM and client's specification are acceptable. Packing: 1.packing length:100,200,305m/roll; 100,200,300yard/roll;n other length available according to client's request 2.inner packing:wooden drum, plastic drum, plastic bag 3.outer packing:carton,plastic bag 4.other packing available according to client's request.
RG6 Coaxial Cable: 1.02CCS/BC+4.57mm Foamed PE+Bonded AL-Foil+0.12mm*80 AL-Mg alloy Braiding+6.9mmPVC Specification : Inner conductor:1.02BC/CCS Dielectric:4.57mm Foamed PE AL-Foil:Bonded AL-Foil;Ordinary AL- Foil, Double-Sided AL- Foil, Single-Sided AL-Foil Braided material: cu;AL-Mg alloy;Copper Clad Aluminum Braided diameter:0.12mm;0.13mm;0.14mm;0.15mm..... Braided net:64;80;96;112.... Braided coverage:50%;60%;70%;80% Jacket:6.8mmPVC ;6.9mmPVC. Characteristics: Impedance:75¡À3.0hms Capacitance(pF/m) :54¡À3.0 Nominal Velocity of Propagation: 85% Return loss(¡ÝdB) : VHF 5-300MHz ¡Ý20dB UHF 300-960MHz¡Ý18dB. Attenuation [@68¡ã F.(20¡ãC.)]: Frequency (MHz) Maximum(dB/100m) 5 1.90 55 5.25 83 6.40 187 9.35 211 10.00 250 10.82 300 11.64 350 12.63 400 13.61 450 14.43 500 15.09 550 16.08 600 16.73 750 18.54 865 20.01 1000 21.49 Applications: 1)CATV-community antenna television 2)CCTV-closed-circuit television 3)DBS-direct broadcasting satellite. 1.Client's specification and designation are welcome. 2.Don't hesitate to contact us! Inquiries and visits are more than welcome. 1)100m/roll,200m/roll,305m/roll 100yard/roll,200yard/roll,300yard/roll (other lengths available client's request) 2)Inner packing:Wooden reel,plastic reel and paper reel available 3)Outer packing:Carton box,pull out box,pallet available (other packing available according to client's request).
5 kv grade single core airfield lighting cables with stranded annealed plain copper conductor xlpe insulated 7 pe or pvc sheathed of size 6 sq.Mm. 500 / 1000 mtrs in non returnable wooden drum with qty tolernce of 5%.
Construction 1)Center conductor: Copper clad steel 2)Dielectric:Foam PE 3)1st shield: Bonded Aluminum Foil(100%) 4)2nd shield:Al-Mg braid(60%) 5)Jacket:PVC. 500ft/1000ft coil in carton.
Construction: 1)Center conductor: Bare Copper 2)Dielectric:Foam PE 3)1st shield: Bonded Aluminum Foil(100%) 4)2nd shield:Al-Mg braid(60%) 5)Jacket:PVC. 500FT/1000FT coil in carton.
7D-FB coaxial cable specification: 1)Inner conductor: Bare Copper or Copper Clad Steel 2)Dielectric:Foam Polyethylene Foam (PE) 3)1st shield: Bonded Aluminum Tape 4)2nd shield: Tinned Copper wire(70%) 5)Jacket:Polyethylene(PE). 500ft/1000ft coil in carton.
Construction: 1) center conductor: copper clad steel 2) dielectric: foam PE 3) 1st shield: bonded aluminum foil(100%) 4) 2nd shield: AL-mg braid(60%) 5) jacket: PVC. 500ft/1000ft coil in carton.
LMR195 specification: 1)Inner conductor: Bare Copper 2)Dielectric:Foam Polyethylene(Foam PE) 3)Outer conductor: Bonded Aluminum Tape 4)Overall Braid: Tinned Copper wire 5)Jacket:Polyethylene(PE). 500ft/1000ft coil in carton.
1.Standard:GB5023.6-2006 IEC60227-6:2001 2.Fire worked stranded bared copper wires or tinned coppr wires 3.PVC jacket and insulator 4.Passed national complusory. 500metre/roll with drum.
1.Standard:GB5023.6-2006 IEC60227-6:2001 2.Fire worked stranded bared copper wires or tinned coppr wires 3.PVC jacket and insulator 4.Passed national complusory . 500metres /rool, in drum.
Pc polished, sm, sx, il45db, lszh 3.0mm, 1mtr. Each patch cord be packed in individual poly bag.
Cable conduits are manufactured in white. They can be easily used in sub plaster or plaster surface installations in interior spaces. They are both decorative and durable. As they are made from PVC, in the event that they catch fire, they are self extinguishing. For this reason, the cables and the area of usage are protected from fire risk. Code Diameter Packaging Quantity KN-9642 16x16 mm 50 mt. KN-9643 25x16 mm 50 mt. KN-9644 40x16 mm 50 mt. KN-9645 25x25 mm 50 mt. KN-9646 25x40 mm 25 mt KN-9647 40x25 mm 25 mt. KN-9648 40x40 mm 50 mt. KN-9649 40x60 mm 50 mt. KN-9650 60X40 mm 50 mt. KN-9651 60x60 mm 50 mt. KN-9652 100x40 mm 25 mt. KN-9653 100x60 mm 25 mt. KN-9654 50x10 mm 50 mt. KN-9655 70x20 mm 50 mt.