JZXC-0.14 type rectifier relay is an important element in interlocking equipment, and is the main equipment to ensure the safe operation of the system. The signal relay can control the switching of the turnout, lock and unlock the way, and control the opening and closing of the signal machine. Its reliability, availability, maintainability and the entire sauna line are the keys to the safety of railway transportation and operation services. The automatic control systems in various fields all use relays. Relays are widely used in railway signal technology, called signal relays, which are important components in railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the relay action directly affects the reliability and safety of the signal system. Product Usage The JZXC-0.14 type rectifier relay is used in the signal circuit for the filament supervision or conversion relay for the electric concentration of small stations and the local power supply in the automatic block section. Features 1. The relay is a heavy elastic rectifier electromagnetic relay, which uses the principle of "constant gravity" to force the moving and closing contacts to open when the coil is de-energized. 2. It adopts silver-silver cadmium oxide contact, which has the characteristics of strong anti-adhesion and low contact resistance. 3. The magnetic circuit adopts electromagnetic pure iron material with small residual magnetism, and a stop piece is installed at the closed position of the armature and the iron core to ensure the minimum air gap of the magnetic circuit, prevent the magnetization of the ferromagnetic parts of the magnetic circuit, and ensure the reliable fall of the relay. 4. The relay is composed of a half-wave rectifier circuit and an infinite relay. The input of the rectifier is alternating current, and the output of the rectifier is ~ Darudapin current 1, current. 5. The relay contact system consists of common contacts, with four groups of common contacts for switching on and off. Applicable environment a) Ambient temperature: -40~+60; b) Relative humidity: not more than 90% (temperature +25C); c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. Dimensions Relay: 165mm 49mm 163mm (length width height) Socket: 157mm 48mm 22mm (length width height)
Product Usage The JWXC-2.3 type infinite relay is used as a DC track relay in the signal circuit. Features 1. The relay is a heavy elastic DC electromagnetic relay, which uses the principle of "constant gravity" to force the moving and closing contacts to open when the coil is de-energized. 2. It adopts silver-silver cadmium oxide contact, which has the characteristics of strong anti-adhesion and low contact resistance. 3. The magnetic circuit adopts electromagnetic pure iron material with small residual, and installs the stop piece at the closed position of the armature and the iron core to ensure the minimum air gap of the magnetic circuit, prevent the magnetization of the ferromagnetic parts of the magnetic circuit, and ensure the reliable fall of the relay. 4. The contact system is composed of ordinary contacts, and there are four groups of ordinary contacts for switching on and off. 5.The rated current of the relay is 280mA DC. Applicable environment a) Ambient temperature: -40~+60; b) Relative humidity: not more than 90% (temperature +25); c) Air pressure: not less than 70KPa (equivalent to an altitude below 3000m); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. product structure Infinite relay is the typical structure of Ax series relay, which is composed of electromagnetic system and contact system. The electromagnetic system includes coil, iron core, choke and armature. The coil is installed horizontally on the iron core, and is divided into a front coil and a back coil. The use of dual coils is to enhance the flexibility and flexibility of the control circuit, which can be controlled by a single coil or a series of double coils according to the circuit needs. The armature is fixed on the blade of the iron by a butterfly-shaped steel wire, which is flexible in movement. There is a heavy hammer in the transmission part of the armature to ensure that the relay armature returns reliably by gravity. The number of weights installed is determined by the structure of the relay contact system, and should be able to ensure the reliable release of the relay. A stop piece is installed at the closed position of the armature and the iron core to ensure the minimum air gap of the magnetic circuit of the relay, prevent the ferromagnetic parts of the magnetic circuit from magnetizing, and ensure that the relay falls reliably. The iron core, choke iron and armature of the relay are made of electromagnetic pure iron, which has high magnetic permeability and small remanence. Installation method
Product Introduction JWXC-1000 type infinite relay is used to close and open the special multi-way switch of signal control circuit. It is an important part of railway signal. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the action of the relay directly affects the reliability and safety of the signal system. Features JWXC-1000 type infinite relay is one of the main components in railway signal equipment. Its reliability and safety in use are necessary requirements to ensure the normal operation of various automatic control and remote control signal equipment. Product function The signal relay is an important component in the interlocking equipment, and is the main equipment to ensure the safe operation of the system. The signal relay can control the switching of the turnout, lock and unlock the route, and control the opening and closing of the signal machine. Its reliability, availability, maintainability and the whole line are the keys to the safety of railway transportation and operation services. Product Usage The JWXC-1000 type infinite relay is used as a general relay in the signal circuit. Executive standard GB/T7417-2010 "Railway Signal AX Series Relay" Product Usage JWXC-1000 type infinite relay (hereinafter referred to as relay) is used as a general relay in the signal circuit. Applicable environment The applicable environment of the relay is: a) Ambient temperature: -40~+60; b) Relative humidity: not more than 90% (temperature +25C); c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. Applicable characteristics Mechanical properties Number of contact groups: 8QH; Identification pin number: 11, 52; Contact gap: not less than 1.3mm; Pallet gap: not less than 0.35mm; Contact pressure: the dynamic contact point is not less than 250mN; the dynamic disconnection point is not less than 150mN; Contact uniformity error: not more than 0.20mm. Electrical characteristics
Product Introduction The JZXC-480 rectifier relay is an important component in the chain equipment and the main equipment to ensure the safe operation of the system. The signal relay can control the switching of the turnout, lock and unlock the route, and control the opening and closing of the signal machine. Its reliability, availability, maintainability and the entire sauna line are the keys to the safety of railway transportation and operational services. The automatic control systems in various fields all use relays. Product Usage The JZXC-480 rectifier relay is used as an AC rail and AC accident relay in the signal circuit. test method Requirements for testing measuring tools, meters, and power supply (1) The accuracy of the measuring tool for measuring the shape and installation dimensions should not be less than 0.05mm; the accuracy of the feeler gauge should not be less than level 2; the measurement error of the force measurement should not be greater than 2%. (2) The accuracy of the DC voltmeter and ammeter used for testing should not be less than 0.5, and the accuracy of the AC (50Hz) voltmeter and ammeter should not be less than 1 (3) The power supply voltage should remain stable, and its fluctuation range should not exceed 5%. The DC power supply should be a DC generator, battery or AC full-wave rectifier power supply (except for special regulations, the ripple factor should not be greater than 5%). The waveform of the AC power supply should be a sine wave with a frequency of 50 Hz. Features The relay is composed of a DC infinite relay and a full-wave rectifier circuit. Applicable environment a) Ambient temperature: -40â??~+60â??; b) Relative humidity: not more than 90% (temperature +25â??); c) Air pressure: not less than 70kPa (equivalent to below 3000m above sea level); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. Dimensions 165mm 49mm 163mm (length width height) Installation method The relay socket is installed on the combination frame (cabinet) with bolts, and the relay is inserted into the socket horizontally and clamped with a hanging spring. Relay identification pin numbers 13, 54. Mechanical properties Number of contact groups: 4QH; 2Q Identification pin number: 13, 55; Contact gap: not less than 1.3mm; Pallet gap: not less than 0.35mm; Contact pressure: the dynamic contact point is not less than 250mN; the dynamic disconnection point is not less than 150mN; Contact uniformity error: not more than 0.20mm.
Product Features JWXC-1700 type infinite relay (hereinafter referred to as relay) is used as a general relay in the signal circuit. Features 1. The relay is a heavy elastic DC electromagnetic relay, which uses the principle of "constant gravity" to force the moving and closing contacts to open when the coil is de-energized. 2. It adopts silver-silver oxide contact, which has the characteristics of strong anti-adhesion and low contact resistance. 3. The magnetic circuit adopts electromagnetic pure iron material with small residual magnetism, and installs the stop piece at the closed position of the armature and the iron core to ensure the minimum air gap of the magnetic circuit, prevent the ferromagnetic parts of the magnetic circuit from magnetization, and ensure the reliable fall of the relay. 4. The contact system is composed of ordinary contacts, with eight groups of common contacts for switching on and off. 5. The rated voltage of the relay is DC 24V. Applicable environment The applicable environment of the relay is: a) Ambient temperature: -40~+60; b) Relative humidity: not more than 90% (temperature +25â??); c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m); d) Vibration: vibration is not more than 15Hz, amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. Mechanical properties Number of contact groups: 8QH; Identification pin number: 11, 51; Contact gap: not less than 1.3mm; Pallet gap: not less than 0.35mm; Contact pressure: the dynamic contact point is not less than 250mN; the dynamic disconnection point is not less than 150mN; Contact uniformity error: not more than 0.20mm. Electrical characteristics (at 20c) Coil resistance: 850 (1±10%) 2 The coils are connected in series, connect 2, 3, use 1, 4; Rated value: DC24V; Magnetizing value: DC67V; Working value: not more than DC16.8V; Release value: not less than DC3.4V; Reverse working value: not more than DC18.4V; Contact resistance: not more than 0.05. Insulation withstand voltage Under the standard atmospheric conditions of the test, the absolute resistance of the relay should not be less than 100MQ. Under the condition that the air pressure is not less than 86kPa (equivalent to the altitude below 1000m), the insulation withstand voltage of the relay should be able to withstand AC sine wave 50Hz, 2000V rms voltage, there should be no breakdown flashover after 1 min, and the voltage during repeated test should be 75% of the original test voltage. Product electrical life The relay contacts are connected to DC24V1A resistive load; its electrical life is 2106 times.
Product Introduction Single Phase Relay Test Set General TKJB SINGLE PHASE RELAY TEST SET is a portable field testing equipment with excellent performance; Elegance and polished appearance with aluminum alloy chassis and PC panel, within the ARM chip control, LCD screen display voltage and current output stopwatch, it could output a full isolation way for adjustable AC/DC voltage, and AC/DC current and a way for adjustable DC voltage; the output loop with double overload protection with large output capacity ,small volume, light weight, high reliability ,It Suitable for field calibration and test for various relay. Product Characteristics Single Phase Relay Test Set Main Features 1 Output a full isolation way for adjustable DC voltage, Automatic protection for short circuit, overload and out range. 2 Maximum Output Current:0150Aã?? 3 Equipped with LCD digital AC/DC volt-ampere meter, can show the AC and DC voltage and current values, stopwatch, potential, contact state. 4 Internal electric stopwatch; Available electrical contacts, maximum potential 250V; Dual channel measurement. 5 Light-weight design, small-volume, and fully-functional.
1. Standard 4-phase voltage and 3-phase current output with 4-phase voltage and 3-phase current output can conveniently carry out various combination outputs for various types of protection tests. Single-phase voltage can output up to 120V single-phase current up to 40A (10 seconds) current three and can output up to 120A the fourth phase voltage Ux is a multi-function voltage item can be set as 4 kinds of 3U0 or check the same period voltage or a certain voltage value of the case output. 2. Single machine is easy to operate. The single machine is operated by a convenient and flexible rotating mouse through a large LCD screen all of which are displayed in Chinese. It can complete most of the field test verification work can verify all kinds of relays and microcomputer protection and can simulate all kinds of complex transient permanent and transformational faults for the whole group of tests. Boot can be used easy to operate. 3. Double operation mode connected to the computer operation through the Windows platform of the full set of Chinese operating software can carry out a variety of large complex and higher degree of automation verification work can be easily tested and scanned a variety of protection fixed value can be real-time storage test data display vector diagram draw fault waveform online print report etc. 4. Software is so powerful that can complete all kinds of high degree of automation of large complex check work such as three phase differential test auxiliary power fast cutting prepared from the cast test line protection inspection period reclosing etc. can easily test and scanning protection setting various fault playback real-time storage test data show that the vector diagram online printing report etc. 5. Switch quantity contact is rich three - phase for 7 contact input and 2 pairs of empty contact output. The input contacts are compatible with 0 ~ 250V potential contacts and can be identified automatically. Input and output contacts can be expanded according to user needs. 6. Large screen LCD display microcomputer relay protection tester adopts 320Ã??240 lattice large screen high-resolution graphics LCD display all the operation process are set on the display screen the operation interface and test results are displayed in Chinese the display is intuitive and clear. 7. Self-protection adopt reasonable design of heat dissipation structure and have a variety of reliable and perfect protection measures and power soft start and a certain fault self-diagnosis and locking function. 8. With an independent dedicated dc power output the device is equipped with one 110V and 220V dedicated dc power output. 9. High cost performance belongs to the cross - professional joint design products integrated multi - professional advanced scientific and technological achievements. Both large tester performance and small tester price with a high performance ratio.
Product Introduction Single Phase Relay Test Set General TKJB SINGLE PHASE RELAY TEST SET is a portable field testing equipment with excellent performance; Elegance and polished appearance with aluminum alloy chassis and PC panel, within the ARM chip control, LCD screen display voltage and current output stopwatch, it could output a full isolation way for adjustable AC/DC voltage, and AC/DC current and a way for adjustable DC voltage; the output loop with double overload protection with large output capacity ,small volume, light weight, high reliability ,It Suitable for field calibration and test for various relay. Product Characteristics Single Phase Relay Test Set Main Features 1 Output a full isolation way for adjustable DC voltage, Automatic protection for short circuit, overload and out range. 2 Maximum Output Current:0150A 3 Equipped with LCD digital AC/DC volt-ampere meter, can show the AC and DC voltage and current values, stopwatch, potential, contact state. 4 Internal electric stopwatch; Available electrical contacts, maximum potential 250V; Dual channel measurement. 5 Light-weight design, small-volume, and fully-functional.
Product Introduction Single Phase Relay Test Set General TKJB SINGLE PHASE RELAY TEST SET is a portable field testing equipment with excellent performance; Elegance and polished appearance with aluminum alloy chassis and PC panel, within the ARM chip control, LCD screen display voltage and current output stopwatch, it could output a full isolation way for adjustable AC/DC voltage, and AC/DC current and a way for adjustable DC voltage; the output loop with double overload protection with large output capacity ,small volume, light weight, high reliability ,It Suitable for field calibration and test for various relay. Product Characteristics Single Phase Relay Test Set Main Features 1 Output a full isolation way for adjustable DC voltage, Automatic protection for short circuit, overload and out range. 2 Maximum Output Current:0150Aã?? 3 Equipped with LCD digital AC/DC volt-ampere meter, can show the AC and DC voltage and current values, stopwatch, potential, contact state. 4 Internal electric stopwatch; Available electrical contacts, maximum potential 250V; Dual channel measurement. 5 Light-weight design, small-volume, and fully-functional.
TKRJ- electronic thermal relay calibration is mainly used for setting and calibration of various thermal relays and motor protection devices. Because of its reasonable design convenient operation and high output power it is widely used in electric test sites of power system railway petrochemical metallurgical and mining enterprises. 1. It can output three-phase 0-500a current at the same time. 2. It can synchronously test the action time of thermal relay thermocouple and motor protector. 3. Normally open and normally closed contact detection. 4. Several calibrations can be connected in series at the same time to improve working efficiency. Product Parameter
Professional Manufacturer for Magnetic Switch, Magnet Reed Switches, Proximity Sensors with Free OEM Customized Service. NC/NO/COM Sensor Switch Solution Supplier.
Key Specifications/Special Features Technical data Type JLW-180 Current range 5-80A Time-current characteristic Definite time Rated voltage 220VAC,50/60Hz Measurement error 1% Protective functions Overcurrent,locked-rotor,phase loss, Additional functions power-on delay,auto reset Indicators LED indicating current,operation status Output contacts 1 C/O Contact capacity 5A 250VAC Dimensions (L x W x D) 70Ã?44Ã?98mm Mounting screw fixing -
.1 Key Specifications/Special Features Technical data Type JFY-813 Current range 1-10A Time-current characteristic Definite time Rated voltage 220VAC,50/60Hz Measurement error 1% Protective functions Overcurrent,undervurrent, locked-rotor,phase loss, phase unbalance Additional functions power-on delay,auto reset Indicators LED indicating current,operation status Output contacts 1 C/O Contact capacity 5A 250VAC Dimensions (L x W x D) 70Ã?44Ã?98mm Mounting screw fixing -
Key Specifications/Special Features Technical data Type JFY-7701 Current range 1-100A Time-current characteristic Definite time Rated voltage 220VAC,50/60Hz Measurement error 1% Protective functions Overcurrent,undervurrent, locked-rotor,phase loss, phase unbalance Additional functions power-on delay,auto reset Indicators LED indicating current,operation status Output contacts 1 C/O Contact capacity 5A 250VAC Dimensions (L x W x D) 70*35*72 mm Mounting screw fixing Features â?? Compact modular size with integrative structure â?? Built-in LED and keypad afford a precise,digital setting â?? Three-phase monitoring of short-circuit, locked-rotor,overcurrent, undervurrent, phase loss, phase unbalance â?? Adjustable reset mode:automatic reset or manual reset â?? Adjustable power-on delay â?? 1 C/O contact Protective Functions â?? Short-circuit â?? Locked-rotor â?? Overcurrent â?? Undercurrent â?? Phase loss â?? Phase unbalance â?? failure warning Typical Applications â?¢ Pumps â?¢ Fans â?¢ Blowers â?¢ Motors â?¢ Compressors Approvals â?¢ CE â?¢ ROHS Main Export Markets Asia Australasia Eastern Europe Mid East/Africa North America Western Europe Central/South America -
Key Specifications/Special Features Technical data Type DZB Rated voltage 220VAC,380VAC,50/60HZ Current range 1-10A,5-50A,10-100A,80-200A200-400A,400-600A,600-800A Proective functions locked-rotor,overcurrent, undervurrent,phase loss,phase unbalance,overvoltage,undervoltage, Optional functions RS-485 communication port4-20mA analog output indicators LED indicating voltage,current,operation status Output contacts 1C/O for trip1C/O for alert Contact capacity 3A 380VAC Dimensions(HÃ?WÃ?Dï¼? 118Ã?54Ã?135mm Mounting Screw fixing Features Integrative structure Built-in LED and keypad afford a precise,digital setting Three-phase monitoring of short-circuit, locked-rotor,overcurrent, undervurrent, phase loss, phase unbalance,overvoltage,undervoltage Earth fault (should couple with ZCT) Fault recording RS-485 communication port (optional) 4-20 mA analog output (optional) 2 C/O output contacts, one for trip,one for alert Protective Functions Short-circuit Locked-rotor Overcurrent Undercurrent Phase loss Phase unbalance Overvoltage Undervoltage Typical Applications Pumps Fans Blowers Motors Compressors Approvals CE ROHS -
GSM BASED RELAY ON/OFF SWITCH 1 CHANNEL TO 4 CHANNEL Remote control using a MOBILE phone from anywhere in the world! - New Feature - Schedule Timer Added The GSM BASED RELAY ON/OFF SWITCH 1 CHANNEL TO 4 CHANNEL is a GSM remote control switch, it connects to the cell phone network and like a cell phone has its own cell phone number. The GSM switch is activated by Sending SMS to its cell phone number, it has 1 TO 4 independent relay switches with normally open and normally closed switch contacts, these can be programmed to switch on and Off By Sending SMS A1 B1 C1 -A0 B0 C0 ..... . SMS text message command. It can report the relay status by sending back a text message. Applications Specification â?¢ Operating Voltage - 12VAC/ DC 2 Amps â?¢ SIM card any Network SPECIFICATION : POWER INPUT: 12v DC-2 Amps RELAY: 250v 7A, 24 10A LIGHT INDICATION: FIRST LED: RED- POWER LIGHT SECOND LED: GREEN â?? BLINK 2 SECONDS ONCE GSM CONNECTED TO NETWORK RELAY ON CORRESPONDING LED WILL GLOWGSM BASED RELAY ON/OFF SWITCH 1 CHANNEL TO 4 CHANNEL Remote control using a MOBILE phone from anywhere in the world! - New Feature - Schedule Timer Added Specification â?¢ Operating Voltage - 12VAC/ DC 2 Amps â?¢ SIM card any Network SPECIFICATION : POWER INPUT: 12v DC-2 Amps RELAY: 250v 7A, 24 10A LIGHT INDICATION: FIRST LED: RED- POWER LIGHT SECOND LED: GREEN BLINK 2 SECONDS ONCE GSM CONNECTED TO NETWORK RELAY ON CORRESPONDING LED WILL GLOW
190 series diesel engineParts body * cam bearing bush 12VB.01.34 Screw compressor accessoriesLS10-30 oil filter element 250025-525 oil well cementAdditive BSG-2 16YT/YZ-14 Inhibitor Macromolecular Cations subpolymer coating inhibitor CHM Drilling rig top drive accessoriesDQ40/DQ50/DQ70 flushing pipe packing 1.04.02.01 Detroit diesel engine parts crank linkage * connecting rod bolts 16V149 23512064 50103-16-B Phase control relay E10922 Canrig 118375 GLYD RING: 10IN DIA PHD50 PHM TDS Remote Console Accessory FKQ6406 Lubricator QAL-4000 Drill pipe tong accessories ZQ203-100 rear box 02-18M PLUG, O-RING, .562-18 87196-6-S 91255 SEAL, HOUSING PLUG, EXT PIPE 53000-4-S Polyacrylamide compound ammonium salt YLAY NK400E engine*exhaust valve O-ring (rubber) S01-1229-01N Canrig DIAPHRAGM PROT ASSEMBLY 15K DIAPHRAGM PROT ASSEMBLY 15K E17-152 Electric control box FKDQ640-7 Explosion-proof switching amplifier Ifm-N0533A DC 24V Plug, Cavity (93667-M11) 93667-M11 Gear Sprocket , Drum type , Mud pump 3NB-1600GIICLZ12 BZ100 15 14 ND1250M306N BottomDisc*Cab Lifter Hydraulic Lines Inductive sensor-NCB10-30GM40-N0-15M 106283 Liquid end accessories TEM-CPT800C SMP-600 plunger 3 1/2" GT550E Chassis*Tiressteel ring Bulb: 48V 25/10W F/Hyster Fork Lift 2027396 Hydraulic tank accessories F-1300 Shear safety valve piston assembly Semicircle retaining ring BK-8-6A Logging tool accessories dipole acoustic logging tool KClog energy storage capacitor 1025486002 Falcon AIR BLADDER W31-20-901 VOLVOFM12 chassis*Cab jack hose Mechanical seal cover of the reverse rotation pump SB6Ã??8FJP SB68FJP0011 Accessories for cementing toolsFGFX insert head 339.7mm POWER SUPPLY\CANRIG\E12823 For 1275AC-681 General test mining tool turntable square tile ZP-275 Valve group 2 BK-T-2 Centrifugal fan YF 04 11kW explosion-proof Floating hoop FG ZX QZ 177.8mm Drill pipe clamp accessories ZQ203-100 Plug screw 0101-26M HH-0625NC-0225-GR8 Roller shaft accessories ZJ-40L Roller shaft assembly 3H106.28.20.00 109586-3 SHIM: BEARING RETAINER TOP DRIVE TDS-9S Spherical hinge P0900031AA MANIFOLD 109547-2 Elevator drill pipe elevator C DZ 109*109mm 2250 Hydraulic control system accessoriesFKQ6406GS master switch CE 0201-72 Winch oil pump drive shaftParts ZJ-32 winch oil pump CB-B63 Drill pipe tong accessories ZQ203-100 pressure cap 0101-21M pressure gauge YNT60 Y16100 Telescopic cylinder PIN ACTUATOR LINK 30172173 SHIM, RESERVOIR MOUNTING (.002) 110147-1 PNEUMATIC TUBE CLUTCH 600X250, FOR DRAWWORKS, MODEL: JC 70D, MAKE: HH, P/N: 1300008438 NB800G.05.15 Bolt M10x20 Liquid end fittings 45-21OFM600 Valve body 3102008950 H10409 DWYER Instruments Air Pressure Switch 1950-20-2F PDC bit 101.6mm M0864 Liner Seal QF36001-05.15 Filter Element: Hyd. 82749 OK019000701 OK TYPE PISTON SEAL SOCKET SET SCREW, 1/2" x 1/2" LONG SS, Part No: 6119, OEM Part no: 23731 Logging tool accessories four-arm caliper logging tool MAXIS-500 special sleeve tool SLB J97
Hour meter This hour meter is mechanical type.Widely applied in each kind of machine, equipment and device(such as environmental protection equipment generator etc). Used for to demonstrate the machine, the equipment, the device accumulation operating time. It is mechanical type accumulation, the longest time for accumulation time can be 11 years. It still can maintain the data after the power cut. Itemno. Bz142-1 bz142-2 bz142-3 Operating voltage ac 24-450v ac 24-450v dc 10-80v Ferquency 50hz 60hz Time range 0-99, 999.99h Dimension 48 x 48 x 40mm Net weight 50g Mounting insert type
Three phase 100A Latching relay TP41-10: -Three phase 100A switching capability ; -Multi layer blades, lower temperature rise ; -Conform to fault making capacity and short circuit current; -carrying capacity of requirement of IEC62066-31( UC3) and IEC61810-1. -It can be applied in three phase 100A electricity meter.
Single phase 80A Latching relay TP41-26: -Single phase 80A switching capability ; -Multi layer blades, low temperature rise ; -Environment protection ( Comply with ROHS) -It can be applied in single phase or three phase 60A Electricity meters.