* 10 A switching capability * subminiature, standard PCB layout * 1 Form A and 1 form C configurations * plastic sealed and flux proofed types available * contact arrangement 1H 1Z * Max. switching current 10A * Max. switching voltage 250VAC/30 VDC * insulation resistance 100m Ω
* outline dimension 18.4*10.2*15.3 * 10A switching capability * 1 Form A and 1 Form C configurations * standard PCB layout * Plastic sealed and flux proofed types available * contact arrangement 1H 1Z * Max. switching current 3A 10A * Max. switching voltage 250VDC/ 30VDC * insulation resistance 1000 Ω
* outline dimension 32.2*27.5*19.8 * 30A switching capability *UL insulation systemï¼? Class F *PCB layout , contact QC layout * Has a set of normally open, normally closed, switch contact form * plastic sealed and dust protected types available * contact arrangement 1A 1B 1C * Max. switching current 30A 15A 20A * Max. switching voltage 277VAC/ 30VDC
* outline dimension 35.2*32.2*24 * 70A withstands inrush current * 30 A switching capability * miniature high power relay, for switching motor ,lamp, heater and other load * QC terminal type * contact arrangement 1H * Max. switching current 30A * Max. switching voltage 277VAC * insulation resistance 1000m ©
* outline dimension 30.5*16*23.5 * switching motor load * 25 A switching capability * ideal for 80 A high surge motor switching * dust protected type * PCB and QC layouts available * contact arrangement 1H * Max. switching current 20A * Max. switching voltage 250VAC * insulation resistance 1000m ©
* 15 A switching capability * Flammability class according to UL94,V * subminiature, standard PCB layout * Plastic sealed and flux profed types available * contact arrangement 1H 1Z * Max. switching current 10A * Max. switching voltage 277VAC/30VDC * insulation resistance 100m ©
* outline dimension 19*15.2*15.5 * 15A switching capability * submuniature , standard PCB layout * 1 Form A and 1 Form C configurations * Plastic sealed and flux proofed types available * contact arrangement 1H 1Z * Max. switching current 10A * Max. switching voltage 277VAC/30CDV * insulation resistance 100m
* outline dimension 19*15.2*15. * 15A switching capability * subminiature, standard PCB layout * 1 Form A and 1 form C configurations * plastic sealed and flux proofed types available * contact arrangement 1H 1Z * Max. switching current 10A
* outline dimension 15.7*12.5*14 * 16A switching capability * Various of motoring positions * Rotating armature structure * SPST ( 1 Form A and B) and SPDT configurations * Dust protected type * contact arrangement SH * Max. switching current 2*6
Pressure relay is a hydraulic term, it refers to the hydraulic system when the fluid pressure reaches a predetermined value, so that the electrical contact action components, is the pressure into electrical signals of the hydraulic components. Customers according to their own pressure design needs, by adjusting the pressure relay, to achieve a set pressure, output an electrical signal function. Competitive brands:� rexroth, HAGGLUNDS, AVENTICS, Danfoss, Parker, MOOG, sunhydraforce, EOWARDS, Leybold, INFICON and other European and American brands. Products:� plunger pump, solenoid valve, gear pump, vane pump, direction valve, servo� valve,� proportional valve, hydraulic valve, hydraulic pump,� etcCompetitive Our Advantages: 1. It has a great advantage in price and inventory. 2. Stable foreign partners to ensure quality and delivery time. 3. Excellent after-sales serive. 4. Flexible paying.
ZJJ DC insulation monitoring relay monitorsthe insulation of the DC bus, and it sendsalarm signal when the bus-to-groundinsulation drops to a certain value,also it ispanel mounted type,and the relay has a high-sensitivity grounding resistance monitoringand display circuit, it is great significance forthe safe operation of the DC system. Monitoring of the DC circuit bus barinsulation resistance RF to LCD screen display resistance value. Bridge balance method for resistancemeasurement. Adjustable response value ranges of 0-100k�©. Smaller short-circuit grounding current forsafe operation.
Voltage Monitoring Series SM 501 86 Cat. No. Parameters MG53BH MG53BF MG63BH MG63BF 415 VAC (3 Phase, 3 Wire) 220 VAC (3 Phase, 3 Wire) Frequency Power Consumption (Max.) 10 VA 5 VA 50/60 Hz Supply Voltage ( ) 105% to 125% (of ) 55% to 95% (of ) Trip Settings Under Voltage Over Voltage Hysterisis 7 V (�± 2 V) of Trip Voltage Phase Loss Phase Sequence Phase Asymmetry Yes Yes LED Indication Storage Temperature Operating Temperature Separate indications for Power ON, UV and OV; ON: Phase Reverse; BLINK: Phase Asymmetry O -15 C To + 55 C O O -25 C To + 70 C O Utilization Category AC - 15 DC - 13 Rated Voltage (Ue): 120/240 V, Rated Current (Ie): 3.0/1.5 A Rated Voltage (Ue): 24/125/250 V, Rated Current (Ie): 2.0/0.22/0.1 A Output Contact Rating Electrical Life Mechanical Life Relay Output 5A @ 250 VAC / 28 VDC (Resistive) 5 1X10 6 3X10 2 C/O Enclosure Dimension (W x H x D) (in mm) Weight (unpacked) Mounting Certification Flame Retardant UL 94-V0 36 X 90 X 60 120 g Base / DIN rail Degree of Protection IP 20 for Terminals, IP 40 for Enclosure ORDERING INFORMATION Note: 1) Voltage Setting Accuracy: �± 5 % of Full Scale; Time Setting Accuracy: �± 10 % of Full Scale 2) In the event of Phase Sequence or Phase Loss, OFF Delay is 100 ms Humidity (Non Condensing) 95% (Rh) 0.5 to 15 s (Selectable) 5 s 0.5 to 15 s (Selectable) 5 s 0.5 to 15 s (Selectable) 5 s 0.5 to 15 s (Selectable) Time 5 s Delay ON Delay Trip Time (OFF Delay) 10% (of ) Cat. No. Description MG53BH 415 VAC, & Single Phasing Preventor (SPP) with Selectable ON Delay (0.5 to 15 sec), 2 C/O MG53BF 415 VAC, UV / OV & SPP with Selectable OFF Delay (0.5 to 15 sec), 2 C/O MG63BH 220 VAC, with Selectable ON Delay (0.5 to 15 sec), 2 C/O MG63BF 220 VAC, with Selectable OFF Delay (0.5 to 15 sec), 2 C/O UV / OV UV / OV & SPP UV / OV & SPP EMI / EMC Harmonic Current Emissions IEC 61000-3-2 Ed. 3.2 (2009-04) Class A ESD IEC 61000-4-2 Ed. 2.0 (2008-12) Level III Radiated Susceptibility IEC 61000-4-3 Ed. 3.2 (2010-04) Level III Electrical Fast Transients IEC 61000-4-4 Ed. 3.0 (2012-04) Level IV Surges IEC 61000-4-5 Ed. 2.0 (2005-11) Level IV Conducted Susceptibility IEC 61000-4-6 Ed. 3.0 (2008-10) Level III Voltage Dips & Interruptions (AC) IEC 61000-4-11 Ed. 2.0 (2004-03) All 7 Levels Conducted Emission CISPR 14-1 Ed. 5.2 (2011-11) Class A Radiated Emission CISPR 14-1 Ed. 5.2 (2011-11) Class B Environmental Cold Heat IEC 60068-2-1 Ed. 6.0 (2007-03) Dry Heat IEC 60068-2-2 Ed. 5.0 (2007-07) Vibration IEC 60068-2-6 Ed. 7.0 (2007-12) 5g Repetitive Shock IEC 60068-2-27 Ed. 4.0 (2008-02) 40g, 6ms Non-Repetitive Shock IEC 60068-2-27 Ed. 4.0 (2008-02) 30g, 15ms RoHS Compliant LED Indications for Power and Fault conditions Voltage Sensing Principle 2 C/O Configuration
EDAM-8067D 8-ch relay(0.5A/120Vac, 1.0A/24Vdc) Output module with LED display * 8-Channels relay Output * Normal Open Relay Output(Form A) * Relay contact rating 5A/120Vac,1A/24Vdc. * Programmable Host Watchdog Timer For Host Failure Protection. * Support MODBUS RTU And ASCII Format
PW336i(6*15A,4*150V)is a powerful secondary injection relay tester with 6-currents and 4-voltages sources.This advanced relay testing set is capable of testing differential relay easily without changing cable connection.Optional upgrade is available to support the test of IEC61850 relay. Features 6*15A, 4*150V Aux DC (0-300V), DC measuring inputs 8 binary inputs, 4 binary outputs Adjustable threshold (0-400V) for binary inputs In-built analog monitoring and recording function Can be upgraded to support the test of IEC61850 complied relay
PW460 (6*15A, 4*300V) is the 3 phase relay test equipment can test all types of protective relays.This relay test kit has in-built output monitoring and recording function and also supports testing kit IEC 61850 IED.Optional accessories include external amplifier,GPS,Circuit Breaker Simulator,Current Booster,etc. Features 6*15A, 4*300V Aux DC (0-300V), DC measuring inputs 8 binary inputs, 8 binary outputs Adjustable threshold (0-400V) for binary inputs In-built analog monitoring and recording function Can be upgraded to support the test of IEC61850 complied relay
PW466i (6*20A, 6*150V) is a powerful secondary injection test set with 6-currents and 6-voltages sources.This advanced secondary injection kit is capable of testing differential relay and synchronizing relay. Optional upgrade is available to support the test of IEC61850 relay. Features 6*20A, 6*150V Aux DC (0-300V) 8 binary inputs, 4 binary outputs Adjustable threshold (0-400V) for binary inputs In-built analog monitoring and recording function Can be upgraded to support the test of IEC61850 complied relay
Triac based ssr Used in control pannel for controlling heater It is generally used in plastic, rubber, pharma, chemical, paper industries 10pecs 48mm*48mm*30mm
Features High performance Embedded-Industrial-Computer. 8.4¡ high-resolution large LCD screen. Display all kinds of test data, operating states, and prompts and help messages. Windows operating system, Slim industrial Keyboard and optical Mouse, and many Hotkeys, most convenient to operate. Perform all test items without any external device, automatically display and record test data, and automatically plot vector diagrams and characteristic curves, and print reports. Provide many automatic test procedures. GPS synchronously trigger, synchronization error less than 50|¨¬S. USB port to transmit data and maintenance operating software. High performance D/A converter, assure high waveform accuracy and excellent linearity, transient response and frequency-amplitude characteristic. Particular waveform generation algorithm, assure pure sine wave. Hi-Fi power amplifier, create high output power and low ripple. Except of traditional Ua, Ub, Uc, Ia, Ib, Ic, the fourth voltage Ux can be applied to many functions, such as 3Uo and synchronous voltage, etc. Eight switch input and Four pairs of idle contact output. Switch input ports are compatible with idle contact and active contact, and capable to identify the polarity of active contact, and work well during ¡¨¤250V. Self-diagnosis and multi-protection, reasonable heat dissipation structure, ensure safety and reliability. Well-designed, high-strength aluminium alloy case with carrying handle, facilitate moving to test on site.
HP-W series Digital Timer Relay features: 1) 4 digit bright LED display, high accuracy: 0.5%FS 2) Power fail memory function 3) Auto cycle timing and delay output 4) 3 timing units, hour, minute and second 5) dimension: 48*48, 96*48, 72*72 6) timing range: 0.01S---999.9H 7) Power supply: 110/220V AC (48*48, 110V should be special ordered). 48*48,72*72,96*48 mm can be choosed, one product in one standard paper box.
Model s40a (3*40a, 3*150v) has large lcd display and panel control facilities. No external pc is required. It can easily test many types of relays, including distance relay, df/dt relay. The rotating mouse and quick touch buttons make the operation very easy. 3*40a, 3*150v Additional 200ma ac current source Aux dc (24v, 110v, 220v) 4 binary inputs, 1 binary output Locally with color lcd (universal relay tester, relay test equipment, 3 phase relay test set, secondary injection test system)