Tannic acid Dear sir We are manf of tannic acid in india, in all grades & very pure form , it will be our pleasure if you are intrested in purchasing our products, we are waiting for your valueable guidence and supply orders for our products. Thanking you 25 kgs h.D.P.E. Bags
5, 6, 7, 8-tetrahydropuinoline Cas no. 10500-57-9 Molecular formula: c9h11n Molecular weight 133.19 Technical index: Apeerance: clear to yellow liquid Puritu: fª99.90% Boiling point: 218-222f¦packing: 200kg/drumstorage and transport: Keep it in shadu , cool and ventilation warehouse , far away from fire and heat source.Be cautious of loading and unloading. Prevent package from damage to avoid leadage. Packing: 200kg/drum
Phosphoric acid Technical grade: H3po4 85%min Chloride as cl 0.0005%max So4 0.005%max Heavy metal as pb 0.001%max Arsenic as as 0.005%max Iron as fe 0.002%max Colority 30max Food grade: H3po4 85%min Chloride as cl 0.0005%max So4 0.005%max Heavy metal as pb 0.001%max Arsenic as as 0.0001%max Iron as fe / Colority 20max In new plastic drums of 35 kgs/330kgs net each.
Laboratory chemicals From 1 Gram to 200 Kilos
Cas No: 9045-22-1 Usage: Generally used as an anticoagulant for blood collection tube in clinical biochemical and emergency biochemical examinations. Its the top choice of anticoagulant for measuring pH, electrolytes, and ionized calcium. Characteristics: Minimal chelation, minimal interference to water and relatively low cation concentration. Production process: Made from heparin sodium through ion exchange. Crude heparin glycolysis-Â Deproteinized-> Oxidative decolorization-resin exchange- Precipitation, Dehydration Drying
Luminol has become one of the most widely used chemiluminescent reagents due to its advantages of high quantum yield, easy synthesis, and good water solubility. Its development process is the same as the arduous process of human beings. From the beginning, there is not much understanding, to the current glow and fever, it can only be summarized in one sentence: gold always shines. In the future, there may be more uses we don't know to benefit our lives. We only need to learn more about it to discover its unlimited potential as soon as possible. Application in the analysis of inorganic substances Using inorganic ions to enhance or inhibit the chemiluminescence of the luminol system, these metal ions can be measured. It is worth pointing out that some metal ions have higher catalytic activity than metal ions after being combined with complexing agents. For example, using the luminol-H2O2-silver phenanthroline system, the detection limit of silver ions can reach 2.7 10-g/L3. The use of sensitizers can improve the sensitivity of detection. The sensitization effect of triphenylmethane derivatives on the luminol luminescence system. It was found that Coomassie Brilliant Blue G250 had the best sensitization effect on the luminol-H2O2-Cu2+ system. A reverse flow injection technique was used to establish a measurement of Cu2+. The new method has a detection limit of 15. The use of the local concentration effect of surfactants to achieve micelle sensitization has been increasingly used in luminescence analysis. For example, the reversed micellar system FIA method is used to measure V4+, the detection limit is Luminol chemiluminescence analysis has been widely used in various fields, and new methods and new technologies are constantly emerging, especially the combination with FIA, HPLC and other technologies, which overcomes the shortcomings of poor selectivity in luminescence analysis and makes the analysis more flexible. Emblem and accuracy. Because of Rumi's stable performance and low price, practical application research and analysis will have broader application prospects.
|English name|3-Morpholinopropane sulfonic acid |Chinese name|3-Morpholinopropane sulfonic acid |Abbreviation|MOPS |CAS#|1132-61-2 |Molecular weight|209.26 |Molecular formula|C7H15NO4S |Storage condition|room temperature, away from light and moisture |Application|Mops is a kind of biological buffer, which is often used to prepare RNA electrophoresis buffer. |Product advantage|The purity is >99%, with good water solubility and stable process, which can ensure that the product appearance is pure white crystal powder. Desheng is a chemical reagent company specializing in blood test reagents with 14 years of R&D experience, especially has a deep research on chromogenic substrate and biological buffer.
Material is borosilicate glass and PP,the normal color is clear and amber.Suitable for HPLC and GC.Has wide application area,it's including food,consumer goods,pharmaceutical,environmental,medical,chemical materials,packing and etc testing. It's economic and convenient suitable for use in Shimadzu VP series, rack 16,Borosilicate glass,olyethylene,Starburst top feature for easy needle penetration,Cap to be packed separately from vials
Brand Name : HiMEDIA, TM MEDIA Pack Size : 500g
Warranty : 3 years Classification : Other, Other Customized support : OEM Brand Name : OEM Model Number : AF0500136001 Place of Origin : China Material : PP
Brand Name : OEM Model Number : YM-1471 Place of Origin : China Product name: coplin jar Certificate : CE/ISO13485 Size: For 5 slides/ For 10 slides Material : Glass Usage : For laboratory / School measuring Packing : standard export carton Specification : 1.5 slides Coplin staining jar 2.Rectangle 10 slides staining jar 3.Round 105(Dia.)x 120(H)mm 26 slides Staining jar 4.Rectangle 30 slides staining jar 5.Round 120(Dia.)x 150(h)mm 30 slides staining jar 6.Rectangle 60 slides staining jar
We guarantee our products are subjected to stringent quality policies to meet industry standards. Our organization has all the essential logistic resources and links to ensure on schedule delivery of order(s).
Product: Giemsa's Stain C.A.S. No.: 51811-82-6 Specifications: Solubility 0.1 % (MeOH) = Clear solution Absorption Maximum(in MeOH) ?1max = 640-650 nm Absorption Maximum(in MeOH) ?2max = 520 - 525 nm Absorptivity (A1%1cm in MeOH at ?1max on dried substance) = 950-1150 Absorptivity (A1%1cm in MeOH at ?2max on dried substance) = 600-750 Loss On Drying (110�°C) =
Product: Leishman's Stain C.A.S. No.:12627-53-1 Specifications: Solubility 0.1 % (MeOH) = Clear solution Absorption Maximum (in MeOH) ?1max = 640-645nm Absorption Maximum (in MeOH) ?2max = 522-525nm Absorptivity (A1%1cm in MeOH at ?1max on dried substance) = >900 Absorptivity (A1%1cm in MeOH at ?2max on dried substance) = >650 Loss On Drying (110�°C) =
Product : Orcein C.A.S. No. :1400-62-0 Specifications: Solubility 0.1 %(0.1N NaOH) = Clear solution Absorption Maximum (0.1N NaOH) ?max = 574-580nm Absorptivity (A1%/1cm in 0.1N NaOH, at ?max) = 250-450 Loss on drying (110�°C) =
Product : o - Cresolphthalein C.A.S. No. :596-27-0 M.F. :C22H18O4 M.W. :346.38gm/mole Specifications: Dye Content (by Spectrophotometry) = >95% Appearance = White-Off white powder Solubility 0.1% (EtOH) = Clear solution Transition Range = pH 8.2-9.8 Colorless-Red Absorption maximum (0.1N NaOH) at ?max = 564-568nm Absorptivity (A1%1cm in 0.1N NaOH at ?max) = >1670 Loss On Drying (110�°C) =
Product: Eosin Blue C.A.S. No.: 548-24-3 CI NO.: 45400 M.F.: C20H6Br2N2Na2O9 M.W.: 624.09gm/mole Specifications: Dye content (By Gravimetry) = >85% Solubility 0.1 % (Dist. Water) = Clear solution Absorption maximum (Dist. water) ?max = 516-520nm Absorptivity (A1%1cm in water at ?max) = >800 Loss On Drying (110�°C) =
Product: Evan's Blue C.A.S. No.: 314-13-6 CI NO.: 23680 M.F.: C34H24N6Na4O14S4 M.W.: 960.82gm/mole Specifications: Dye Content (by Spectrophotometry) = >85% Solubility 0.1 % (Dist. Water) = Clear solution Absorption maximum (Dist. water) ?max = 605-611nm Absorptivity (A1% 1cm in water, at ?max, on dried substance) = >800 Loss On Drying (110�°C) =
Using imported high-purity PFA material, with extremely low background, smooth surface and no adsorption. The cavity is transparent and visible for easy observation. Pagoda condensation design, no water cooling, efficient acid production. Characteristics: 1)High purity acid preparation system anti-corrosion low background 2)Specification: 1L/2L/4L/5L/6L 3)Applicable experiments: semiconductor analysis,isotope analysis,trace element detection experiment 4)Applicable to HCL,HF,HNO3 in laboratory 5)Operating temperature: room temperature 250 6)Translucent and visible, low background, Low blank value of metal elements (Pb or U 0.01 ppd) No dissolution and precipitation.
Product Description : Flasks can be used for making solutions or for holding, containing, collecting, or sometimes volumetrically measuring chemicals, samples, solutions, etc. for chemical reactions or other processes such as mixing, heating, cooling, dissolving, precipitation, boiling or analysis.