Moisture meter mc-7825ps Model: mc-7825ps Meaning: pin ·¬ search type Specifications: wood over 150 species Building moisture: 0-50% Measuring range: 0-80% Resolution: 0.1 Display: lcd display Accuracy: f+(0.5%n+0.1) Power supply: 4x1.5v aaa (um-4) battery Battery indicator: low battery indicator Dimensions: 165x62x26mm Weight (not including probe):175g Dimensions: 165x62x26mm
Can measure the thickness of non-magnetic coating layers on magnetic substrate, such as: (aluminum, chrome, copper, enamel, rubber, plaint) on magnetic substrate(steel, iron, alloy and magnetic stainless steel), and can measure the thickness of nonconductive coating layers covered on nonferrous substrate, such as:(ename1, rubber, paint, vanish, plastic anodic-oxide layer) covered on nonferrous substrate(aluminum, brass, nonmagnetic stainless steel) Model: cm-8820, cm-8821, cm-8822, cm-8823, cm-8825fn, cm-8825f, cm-8825n, cm-8826fn, cm-8826f, cm-8826n, cm-8829, cm-8829s. Dimensions: 160x68x32mm
Tsr-3296 trimming potentiometer With 5 terminal styles Electrical characteristics Resistance range: 10ohm~2mohm Tolerance: 5%, 10% Contact resistance variatio: crv
Electronic KWH Energy Meter Single/three phase static energy meter single/ three phase prepaid static energy meter single/three phase multi-tariff static energy meter single/three phase tamper-proof static energy meter single/three phase wave carrier static energy meter single/three phase multi-function static energy meter single/three phase wireless multi-function static energy meterenergy distribution monitor. And the accuracy class is 0.5, 0.5s and 1.0. The voltage range is from 100v to 480v. And the current range is from 1.5a to 100a. It is packaged by box.
Diaphragm gas meter Description Model SY-RQM Diaphragm type gas meter applies to measure the consumption of coal gas, liquefied petrol gas and natural gas. It can also be used to measure the flow rate of are and other gases. Features New design, Exquisitely-made; High sensitivity, Accurate metering, Easily-installed and Maintained; quipped with anti-reverse facilities, Adopted advanced surface treatment, Corrosion-resistant, Long operation life, The shell is cast with aluminum-alloy, diaphragm structure. Big digital wheel equipped. The casings for SY-RQM-1.6 & SY-RQM-2.5 are identical
31;057906461C;057906461CX;0281002735;03G906461C;06J906461D;AFH6037;;AFH70-08C;078133471C
Function 1. Observe thermal stress distribution after annealing 2. Measure glass tempering grade 3. Measure optical retardation caused by thermal stress in glass  Detecting object transparent glass products with complex construction. such as : glass container , glass handicraft ,glassware , tableglass , lamp penicillin bottle, light tube, light bulb,solar glass ,automobile glass etc Detecting methods Sensitive Color Tint Method and Senarmont Compensation method Specification Model PSV-413L Analyzer Diameter 78mm Viewing field 400 400mm Glass tempering grade 0-10 Measuring range ( Optical retardation ) 0-280nm Measure height ( adjustable ) Max 600mm Light Source Warm white LED light 10W Power 220VAC 50-60HZ Size W485 D584 H732mm Weight 14Kg
The unit is low cost, easy-to-use, individual and multifunctional that enables to measure all the basic parameters required in an electrical installation and monitors electricity over and above basic metering. The entire range is very rugged and cost-effective. All these products are field proven and more than 100,000 units are active in service.
Function 1.Observe stress distribution in transparent plastic, glass products and optical crystals 2.Measure retardation caused by internal stress in glass and optical crystals Detecting object 1. transparent glass products with complex construction. such as : penicillin bottle, ampoule , mobile phone cover, light tube, light bulb,solar glass ,automobile glass,sapphire, glass container , glass handicraft 2. transparent plastic samples plastic bottle , cosmetic bottle , beverage bottle, contact lenses, plastic tray plastic film 3. optical crystals such as quartz , SiC, calcium fluoride Detecting methods Sensitive Color Method and Senarmont Method Specification Model PSV-413 Size W291D384H388mm Measuring range 0-280nm Weight 11Kg Viewing field W200D200mm Measure height max259mm Light Source Warm white LED light 10W Power DC 12V(with a AC/ DC adapter)
2in1 meters measure two different ranges of frequencies in the range of 45 to 450Hz. For maximum accuracy, the essential measuring range is obtained by suppressing unwanted frequency span. The meter is housed in UL94V-0 approved polycarbonate case and can be mounted in Mosaic mounting.
ML14xx is Multiload Monitor with 12 single phase load or 4 three phase load option. It measures important electrical parameters of multiple loads simultaneously in a single unit, eliminating the need and cost of multiple panel meters. It provides quick, easy and error free current connections with plug and play connectors. It measures real time electrical parameters like Active / Reactive / Apparent energy and power, current, THD, demand, max demand for each load. The instrument has 4 configurable relay outputs, which can be used for Limit / Pulse / Residual Current / 3Phase Load Health Monitoring / Tariff / RTC / Timer tripping or alarms. This instrument communicates with either MODBUS or Ethernet connection
An ultrasonic flow meter is a type of flow meter that measures the velocity of a fluid with ultrasound to calculate volume flow. Using ultrasonic transducers, the flow meter can measure the average velocity along the path of an emitted beam of ultrasound, by averaging the difference in measured transit time between the pulses of ultrasound propagating into and against the direction of the flow or by measuring the frequency shift from the Doppler effect. Ultrasonic flow meters are affected by the acoustic pr
An ultrasonic flow meter is a type of flow meter that measures the velocity of a fluid with ultrasound to calculate volume flow. Using ultrasonic transducers, the flow meter can measure the average velocity along the path of an emitted beam of ultrasound, by averaging the difference in measured transit time between the pulses of ultrasound propagating into and against the direction of the flow or by measuring the frequency shift from the Doppler effect. Ultrasonic flow meters are affected by the acoustic pr
Product overview Hand-held ultrasonic flow meters enable non-contact measurement of liquid flow. The flow is measured by mounting the sensor on the outer wall of the pipe. It has the characteristics of small size, convenient carrying and accurate measurement. It is widely used in tap water, heating, water conservancy, metallurgy, chemical, machinery, energy and other industries. It can be used for production monitoring, flow verification, flow inspection, water balance adjustment, energy saving monitoring, and is an essential tool for real-time flow detection. Technical parameters Category Performance, parameters Host Principle Ultrasonic time difference principle Accuracy ±1% Display 48 Chinese or 416 Western-style dot matrix backlit LCD monitors, supporting Chinese, English, Italian and French. Signal output 1 channel OTC pulse output (pulse width 6~1000ms, default 200ms) Data interface The RS232 serial interface is isolated and the flowmeter can be upgraded via a PC. Pipe condition Pipe material All dense pipes such as steel, stainless steel, cast iron, copper, PVC, aluminum, and glass reinforced plastic are allowed to be lined. Pipe inner diameter 15~6000mm Straight pipe The sensor installation point is best to meet: upstream 10D, downstream 5D, Distance to pump outlet30D (D is the pipe diameter) Measuring medium Kind Water, sea water, industrial sewage, acid and alkali, alcohol, beer, various oils and other single average liquids that can conduct ultrasonic waves. Temperature -30�ºC~160�ºC Turbidity 10000ppm and small bubble content Flow rate 0~�±10m/s Working environment Temperature Host:-20C~60C Flow Sensors:-30C~160C Humidity Host:85%RH Sensor protection level IP67 Power supply Three built-in 1.2V rechargeable NI-MH batteries with a capacity of 2000AH, which can work continuously for more than 12 hours every time. Different measurement can be achieved by using the AC90~260V power adapter. Power consumption 1W Shell material Flame retardant ABS Host weight 390g
Product overview Hand-held ultrasonic flow meters enable non-contact measurement of liquid flow. The flow is measured by mounting the sensor on the outer wall of the pipe. It has the characteristics of small size, convenient carrying and accurate measurement. It is widely used in tap water, heating, water conservancy, metallurgy, chemical, machinery, energy and other industries. It can be used for production monitoring, flow verification, flow inspection, water balance adjustment, energy saving monitoring, and is an essential tool for real-time flow detection. Technical parameters Category Performance, parameters Host Principle Ultrasonic time difference principle Accuracy ±1% Display 48 Chinese or 416 Western-style dot matrix backlit LCD monitors, supporting Chinese, English, Italian and French. Signal output 1 channel OTC pulse output (pulse width 6~1000ms, default 200ms) Data interface The RS232 serial interface is isolated and the flowmeter can be upgraded via a PC. Pipe condition Pipe material All dense pipes such as steel, stainless steel, cast iron, copper, PVC, aluminum, and glass reinforced plastic are allowed to be lined. Pipe inner diameter 15~6000mm Straight pipe The sensor installation point is best to meet: upstream 10D, downstream 5D, Distance to pump outlet30D (D is the pipe diameter) Measuring medium Kind Water, sea water, industrial sewage, acid and alkali, alcohol, beer, various oils and other single average liquids that can conduct ultrasonic waves. Temperature -30C~160C Turbidity 10000ppm and small bubble content Flow rate 0~±10m/s Working environment Temperature Host:-20C~60C Flow Sensors:-30C~160C Humidity Host:85%RH Sensor protection level IP67 Power supply Three built-in 1.2V rechargeable NI-MH batteries with a capacity of 2000AH, which can work continuously for more than 12 hours every time. Different measurement can be achieved by using the AC90~260V power adapter. Power consumption 1W Shell material Flame retardant ABS Host weight 390g
Size DN3-DN3000 Electrode:SS316,HC,HB,Ti,Tan,Pt Liner Material: PTFE,PFA,FEP,NEOPRENE,HARD RUBBER Accurance: 0.5% of reading velue,0.3% and 0.2% optional Connection: Flange,Tri-clamp,Wafer,Union Introduction Electromagnetic flow meter is hallmarked by its high performance and reliability based on successful, field-proven technology. It is being widely used in industries such as petroleum, chemical engineering, iron and steel, food, electricpower, paper making, water treatment, petrochemical, medicine etc Features Medium temperature can be -20~200. Integrated vertification, diagnostic function and empty pipe detection. Measure forward and reverse direction flows. Built-in reference electrodes, no need to connect ground ring. Dual frequency excitation and stable zero point. Precision coil winding technology, makes magnetic field more uniform. High protection grade,IP65. No moving parts, no pressure loss. High accuracy: ±0.5% of reading,±0.3% and ±0.2% optional, velocity >0.3 m/s. Application Chemical Medicine Beverage Iron and steel Water supply Electricpower Water treatment
3 1/2 digits 18mm LCD Range: 1~100,000Lux Accuracy: â?¤10,000Lux, ±(4%rdg+10digit) , >10,000Lux, ±(5%rdg+10digit) Resolution: 1Lux Repeatability: ± 2% Temperature Characteristic: ± 0.1%/ Sampling Time: 0.5 second Photo detector: one silicon photo diode with fliter Dimensions: 130Lx72Wx30H(mm) Over-input: Indication of 1
3 1/2 digits 18mm LCD Range: 0.1~200,000Lux/0.01~20,000FC Over-input: Indication of 1 Accuracy: â?¤20,000Lux, ±(3%rdg+10digit) ã??ã??ã??ã??ã?? >20,000Lux, ±(5%rdg+10digit) Resolution: 0.1Lux Repeatability: ±2% Temperature Characteristic: ±0.1%/ Sampling Time: 0.5second Photo detector: one silicon photo diode with fliter Dimensions: 160Lx79Wx43H(mm) Date hold, peak hold Display in Lux and FC switchable
Model: CCZ1000 Description: CCZ1000 Portable Digital Dust Meter Introduction: 1. Micro-processor technology, fast data process, good anti-interference ability, good stability, high precision, digital display, small volume, light weight, easy operation, convenient use. 2. Applicable for coal mining or dust work place. 3. Directly detect the concentration of total dust or respiratory dust. Technology parameters: 1. Concentration range: (0.5~1000) mg/m3 2. Concentration relative error: â?¤ ± 15% 3. Sampling flow: 2L/min 4. Sampling flow error: â?¤ 2.5% 5. Sampling flow stability: â?¤ 5% 6. Display mode: LCD 7. Continuous working time: â?¥ 10h
Product Name: Digital Multi-meter Introduction: 1. Built-in rectifier, measure alternating/direct current, voltage, resistance and other electrical parameters. 2. Consisted with magneto electric ammeter, measuring circuit and option switch. 3. Measure a variety of electrical parameters by using option switch. Technology parameters: Measuring range Accuracy DC voltage 200mV/2V/20V/200V/1000V ± (0.05%+3) AC voltage 200mV/2V/20V/200V/750V ± (0.8%+25) DC 200uA/2mA/20mA/200mA/20A ± (0.5%+4) AC 200mA/20A ± (1.5%+25) Resistance 200Ω/2k Ω/20k Ω/200k Ω/2M Ω/20M Ω ± (0.2%+5) Capacitance 20nF/2uF/200uF ± (4.0%+50) Frequency 20kHz/200kHz ± (1.5%+25)