The main functions and features : Meter circuit design and selection of the components are according as the tolerance of greater choice of environment, so we can guarantee long-term stability of a piece of work. Basically error will not affected by the frequency, temperature, high harmonics, and the installation of location is arbitrary. After sealing unit manufactured without adjustment, greatly reduced the power sectorf+s workload of testing and calibration, meter - button box with pulse interface light coupler facilitate error testing. Detection the constant of pulse output / kw.H to find weather it is the same as constant table marked on nameplate meter, meter also provides low-frequency pulse acquisition (opts). When the one phase of three-phase three-line network is broken, three-phase four-wire network with a two-phase power outages, the watt-hour meter still normal, and display the lost pressure. Power meter in the factory before carefully debugging and test the installation of qualified lead seals. Energy applies to an ambient temperature of -25 fp c to 70 fp c and relative humidity over 85% of the region. Main technical parameters Reference voltage 220/380v 3 * Voltage reference 0.7 u un .2 b -1. Current specifications 3 * 5 (20) a. Reference frequency 50hz. Grading accuracy 2.0 Starting current 0.4% ib. Voltage power lines "0.8w Communication transmission distance 5m. Environmental conditions -25fï+70elative humidity -_85% Automatic relay depth Data transmission speed Center frequency Dimensions. Current specifications 10-40a Reference frequency 50hz. Grading accuracy 2.0 Starting current 0.4% ib. Voltage power lines "2w Communication transmission distance 5m. Environmental conditions -10f¦f+50f¦relative humidity Automatic relay depth Data transmission speed Center frequency Dimensions 166 * 123 * 74.
Detailed product description 1. Power meter measures voltage, current, power, power factor, kwh, kvarh 2. Rs485/ modbus 3. Power quality analysis 4. Di/do PMAC735 power meter features: 1. Suit for lv/ hv voltage system 2. Compact design with all real-time measurement 3. Consist of basic unit and optional modules 4. 10 years back-up of integrated energy data 5. Large lcd, high brightness, auto-scrolling 6. High accuracy, v or i is 0.2%, kwh is class 1 7. Ct and pt programmable 8. Pluggable terminals, easy to install 9. Panel size: 96 x 96mm 10. Password protect PMAC735 power meter basic function: Provide one rs485 communication, measures and display real-time parameters: 1. Voltage¡ªua, ub, uc, uab, ubc, uca, 2. Current¡ªia, ib, ic, in 3. Active power ¨c pa, pb, pc, p 4. Reactive power ¨cqa, qb, qc, q 5. Apparent power¡ªsa, sb, sc, s 6. Power factor¡ªpfa, pfb, pfc, pf 7. Frequency 8. Active energy¡ªkwh (4 quadrant) 9. Reactive energy¨c kvarh (4 quadrant) 10. Demand and max. Record for i, p, q, s 11. Unbalance rate for u, i 12. Max./ min. Value Pmac735 power meter di/ do modules: 1. 4 status input + 4 relay output 2. 8 status input + 2 relay output 3. 8 status input + 2 pulse output 4. Profibus communication module Pmac735 power meter optional function: 1. Up to 31st harmonic analysis, k factor, thd 2. Soe (event log) 3. One 4~20ma analog output. Pilot's packing; neutral packing; customized packing.
Optical power meter sxbk-2a 1). General The optical power meter sxbk-2a is designed to detect the continuous optical power of wavelength ranged in 800nm-1700nm. With high resolution, it provides calibration points at different wavelength of 850nm, 1300nm, 1310nm and 1550nm, and indicates the optical power in either linear or nonlinear mode. The instrument is supplied with a big lcd to display in various units such as mw (ª8w, nw), dbm, and db. It also provides functions including automatic range switch, automatic shutdown and battery low alarm. It features small size, light weight, elegant appearance, endurance, simple operation and low power consumption so that it can widely applied in various domains such as cable construction and maintenance, optical communication, fiber sensing, and fiber catv etc. 2). Product parameters Probe typefc/pc Power ranger+23 dbm to -40dbm Wavelength ranger800nm ~ 1700nm Calibrating wavelength850 nm, 1300 nm, 1310nm, 1550nm Accuracyí0.15db Resolution0.01db Displaying unitdb/dbm/watt (mw, uw, nw) Connectorfc/st replaceable Battery typeone 9vdc battery Battery service time (at normal temperature)í²10 hours Auto shutdown time10 minutes Working temperature -10ípc to +50ípc Storage temperature-40ípc to +70ípc Relative humidity0 to 95% (no condensation) Dimensions (mm)70 íß 135 íß 24 Weight (kg)0.15
Optical power meter sxbk-2a 1). General The optical power meter sxbk-2a is designed to detect the continuous optical power of wavelength ranged in 800nm-1700nm. With high resolution, it provides calibration points at different wavelength of 850nm, 1300nm, 1310nm and 1550nm, and indicates the optical power in either linear or nonlinear mode. The instrument is supplied with a big lcd to display in various units such as mw (8w, nw), dbm, and db. It also provides functions including automatic range switch, automatic shutdown and battery low alarm. It features small size, light weight, elegant appearance, endurance, simple operation and low power consumption so that it can widely applied in various domains such as cable construction and maintenance, optical communication, fiber sensing, and fiber catv etc. 2). Product parameters Probe type ¦fc/pc Power ranger¦+23 dbm to -40dbm Wavelength ranger¦800nm ~ 1700nm Calibrating wavelength¦850 nm, 1300 nm, 1310nm, 1550nm Accuracy¦a0.15db Resolution¦0.01db Displaying unit¦db/dbm/watt (mw, uw, nw) Connector¦fc/st replaceable Battery type¦one 9vdc battery Battery service time (at normal temperature)¦10 hours Auto shutdown time¦10 minutes Working temperature¦ -10c to +50c Storage temperature¦-40c to +70c Relative humidity¦0 to 95% (no condensation) Dimensions (mm)¦70 135 24 Weight (kg)¦0.15
Three phase electrical network power quality detection device, provide energy consumption and generate; THD (Total Harmonic Distortion); Harmonic individual data reading. Build-in 4 tariffs energy logger function, with onboard memory can record last three month energy data, free to set max 12 segment record period, can be use as a commercial billing unit. Features ·Class 0.5S power and energy ·Current measuring .../5 or .../1 A ·Backlit LCD display ·Expandable input / output modules (up to 3 modules) ·With RS-485 Modbus/RTU Communications ·With 2 channel Pulse Output (PO) for active energy&reactive energy counting ·Optional 1 channel Analog Output (AO) ·Optional 4 channel Digital Input (DI) and 2 channel Digital Output (DO) ·Record and read multi- tariffs ratio, Up to 3 months ·ITF Technology: galvanic insulation protection inputs outputs ·Universal series power supply (85-265VAC/DC) Application ·Applied to the control of general switch boards and low, medium and high voltage connection points. ·Harmonic analyze. ·Remote data reading. ·Alarm station with voltage-free digital inputs.
High-end multifunction power analyzer manufactured by Blue Jay Technology. higher measurement accuracy, and powerful functions. With its four direct access keys and TFT displays, friendly full text interface helps user operate device more easy. Max 52th harmonic individual monitor, let user clear grasp of the present electrical grid quality. Features ·Class 0.2 power and energy ·Current measuring .../5 or .../1 A ·Clear and large matrix LCD screen ·Expandable input / output modules (up to 3 modules) ·With 2 channel Pulse Output (PO) for active energy&reactive energy counting ·With RS-485 Modbus/RTU Communications ·Optional 1 channel Analog Output (AO) ·Optional 4 channel Digital Input (DI) and 2 channel Digital Output (DO) ·Record and read multi- tariffs ratio, Up to 3 months ·Electrical parameter MD record ·ITF Technology: galvanic insulation protection inputs outputs ·Universal series power supply (85- 265VAC/DC) Application ·Metering of distribution feeders, transformers, generators, capacitor banks and motors. ·Medium and low voltage systems. ·Commercial, industrial, utility. ·Power quality analysis. ·Harmonic measurement.
Model ytms006 Seal material abs plastic Wire material galvanized steel wire/copper wire nylon Coated wire/stainless steel wire/mixed with kinds of material Color yellow/red/green/blue/purple etc. Printing laser marking Wire length 150mm or others as per request Options printing logo, name, numbering and bar code
Model PON power meter 1310nm 1490nm 1550nm Pass Zone(nm) 12601360 14701505 15351570 Isolation (dB) >40@1490 >30@1310 >40@1310 Isolation(dB) >40@1550 >40@1550 >40@1490 Measurement Range(dBm) -40+10 -40+10 -40+20 Measurement Accuracy Connatural uncertainty(dB) ±0.5 Linearity(dB) ±0.1 Passing through insertion Loss(dB)
Advantages: Tiny size: 2 module; Lora/RS485 version; Powered installation; Cloud management Features: Measuring all parameters: three phase voltage, current, line voltage, active power, reactive power, apparent power, power factor, frequency, active energy, reactive energy 1 interface* RS485 Modbus RTU communication protocol 1* programmable energy pulse output LCD display The DZS310 are three phase multi-channel power & energy meters. They are featured with excellent cost effectiveness and space performance It can fulfill measurement in flexible mode, also realize the functions of power quality management, load control, over current and voltage protection etc.
Current : 99t1-a sq48-a Voltage : 99t1-v sq48-v Frequency : 99t1-hz sq48-hz Power : 99t1-kw sq48-kw Power factor : 99t1-cos sq48-cos
Single Phase DIN-Rail Energy Meter (DDS-1Y-L) Executive Standard: IEC62052-11 2003; IEC62053-21 2003 and IEC62056-21(IEC1107) DIN-rail standard: "SO"43864. Function and characteristic: Single measurement(optional RS485 or RS485 Modbus) High accuracy of measure, convenient installation; Logical design of Anti-creep. Technical data: Rated voltage: 110V, 120V, 220V, 230V Rated Current: 1.5(6)A, 5(60)A, 10(100)A Frequency: 50-60Hz Connection mode: CT type; Direct type Display mode: LCD 5+2 = 99999.99kWh Accuracy Class: 1.0 Power consumption: 1W (when 220V 20A) Start current: 0.004Ib Constant: 12800 imp/kWh; 800/1600/3200/6400 imp/kWh Standard work temperature: -20-45 degree Climate work temperature: -30-55 degree Relative humidity: 85%. Size: 100*76*65 mm.
DIN-Rail Single Phase Energy Meter with Counter(DDS-1Y-M) Executive Standard: IEC62052-11 2003; IEC62053-21 2003 DIN-rail standard: "SO"43864. Function and characteristic: Long terminal block; Nameplate inside; Measure power accurately; Anti-creep. Technical Data: Rated voltage: 110V, 220V, 230V, 240V; Rated current: 5(30)A, 5(60)A, 10(80)A, 5(80)A; Frequency: 50-60Hz Connection mode: Direct type Display: Counter 6+1=999999.9kWh Accuracy Class: 1.0 Power consumption: Un1W (when 220V 20A) Start current: 0.004Ib Standard work temperature: -20-45degree. Crelative humidity: 85%. Size: 115*78*65mm.
Three Phase Double Tariff Meter (DTS353) Executive Standard: IEC62052-11 2003; IEC62053-21 2003 DIN-rail standard: "SO"43864. Function and characteristic: Two tariffs; Double LCD; Control tariff by exterior controller; Two display window for two different tariffs T1, T2. Technical data: Rated Voltage: 3*220V/380V; 3*230V/400V Rated Current: 3*5(30)A; 3*10(60)A; 3*10(100)A Frequency: 50-60Hz Connection Mode: Direct type Display: LCD 5+1=99999.9kWh Accuracy Class: 1.0; Power Consumption: Less than 0.6W; Less than 0.3VA Start current: 0.004Ib Constant: 800/1600/3200/6400imp/kWh. Size: 122*100*65mm.
Single Phase kWh Meter Executive Standard: IEC62052-11 2003; IEC62053-21 2003 Function and characteristic: Infrared function; Measurement accurately. Technical data: Rated current: 1.5(6)A 5(30)A 10(40)A 5(60)A 20(80)A Rated voltage: 110V 220V 230V 240V Display mode: LCD 6+1=999999.9kWh Accuracy class: 1.0 Frequency: 50Hz (60Hz) Impulse constant: 800/1600imp/kWh Connetion mode: CT type; Direct type. Size: 153*118*50mm.
Single-phase prepaid kWh meter Type: DDSY716 Name: Single-phase pre-payment electricity kilo watt-hour meters Accuracy: Class 1.0 Class 2.0 Power Consumption:
Water meter flow meters Porter:sales9@gnflowmeter.com Site:www.microflowmeter.com Skype:shcixi_ru water meter flow meters(mini oil water flow meter) principle is a liquid pushing one pair of oval gears; volume of each cavity is a fixed volume; gear speed leads, the sensor sends the sync pulse count, oval gear rotated by the magnetic seal coupling and reduction gear mechanism passed directly to the counter indicates the total flow through the meter. If the additional transmission means, the display of water meter flow meters together with electrical instrument can achieve remote only instantaneous flow or accumulated flow. The water meter flow meters with 0.2% accuracy and low flow range.the high temperature is 200C,the max pressure is 1000Bar.the output is pulse and material is stainless steel and aluminum. Model Flow range Connection CX-M2-SS/AL 0.5~150 ml/min G1/8 female thread CX-M3-SS/AL 1-300 ml/min G1/8 female thread CX-M5-SS/AL 5-1000 ml/min G1/8 female thread CX-M6-SS/AL 0.5-100 l/H G1/4 female thread CX-M9-SS/AL 5-550 l/H G1/4 female thread CX-M12-SS/AL 1~30 L/min G1/2 female thread CX-M25-SS/AL 5-110 l/min G1 female thread CX-M40-SS/AL 10-250L/min G1 1/2 female thread CX-M50-SS/AL 10-500L/min G2 female thread Feature 1) Compact and economical design suited for OEM 2) High accuracy and repeatability 3) No requirement for flow conditioning 4)Stainless steel rotors 5) Measures high and low viscosity liquids 6)Original Equipment Manufacturers Select the JSN and select the water meter flow meters,we will provide the professional service for you.
Electric meter The main functions and features : 1. Energy measurement ways: total single-phase power meritorious =positive meritorious + reverse meritorious. 2. Right through infrared interface programming meter settings and copied sheet data to support meter reading with shrinking table, table factory default is bar code numbers. 3. After the blackout enter low-power work, in the blackout shows that the current state of total consumption, continuous 24-hour blackout revealed about the closure. 4. Meter procedural device to prevent the failure caused flight function, and after the failure to stop measurement. Main technical parameters Reference voltage 220v Voltage reference 0.7 u un .2 b -1 Current specifications 10-40a Reference frequency 50hz Grading accuracy ++ level Starting current 0.4% ib Voltage power lines "2w Communication transmission distance 5 meters Environmental conditions -25fªf+55fª Relative humidity 25f+95+¦ Automatic relay depth Data transmission speed Center frequency Dimensions 150 * 122 * 56.5
Model J0408 DC Voltmeter is suitable for students to measure the voltage in a DC circuit in laboratory. Measuring Range: -1~0~3V -5~0~15V Accuracy: 2.5%f.s. Sensitivity:1mA Dimensions: 138*100*97mm
Jaundice meter Features: Measure with no wounds, no pain, no infection; Small exterior, easy to be hold; Big lcd three digital display, easy to check the measure data(stb); Battery copacity indicator in lcd. Specifications: Measurement methods: light reflecting Measure data display: three digital lcd display(mg/dl) Startup time: >5s Accuracy: (0.0-15)+-1;(16-25)+-1.5 Product size: 182*57*31mm Net weight:200g (include batteries pack)
PH Meter