4p 1000V DC Solar Mini Circuit Breaker Description: PQB1Z-63 4P PV DC breaker supplementary protectors are designed to provide overcurrent protection within appliances or electrical equipment, where a branch circuit protaction is already providedd or not required. Devices are designed for direct current(DC) control circuit applications. Technical Parameter: Item DC MCB Code PQB1Z-63 Pole 1P 2P 3P 4P Voltage 250VDC 550VDC 800VDC 1000VDC Current 1A,3A,6A,10A,16A,20A,32A,40,50A,63A Standard IEC/EN60947 Breaking Capacity 6KA,10KA Characteristic Curve B,C,D Working Temperature "-5°"to +40° Protection Degree IP20 Electrical life More than 8000times Mechanical life More than 2000times Dimension(W)X(H)X(D) 18X80X71 36X80X71 54X80X71 72X80X71 Installation 35MM DIN RAIL Accessory YES Installation Altitude â?¤2000M
L7 Miniature Circuit Breaker Application L7 series circuit breaker is used in lighting distribution system or motor distribution system for protection overload and short-circuits in the system. The product is neoteric in structure, reliable and excellent in performance. It has high breaking capacity, can trip quickly, and its case and items are adopted by high fire-resistant and shockproof plastic. The product, with long life, is mainly used in AC 50HZ/60HZ single-pole 230V or two, three, four poles 400V circuit for overload and short-circuit protection as well as for infrequent on-and-off switching electric equipment and lighting circuit in normal case. The products comply with IEC 60898.
Our featured products automatic transfer switch, circuit breaker, contactor, pilot light,relay, SPD, etc. with solid quality and considerable price and could equip them with enclosure. Circuit Breaker DZ47 is an automatically operated electrical switch designed to protect an electrical circuit from damage caused by overload or short circuit. Its basic function is to detect a fault condition and, by interrupting continuity, to immediately discontinue electrical flow. When a current is interrupted, the arc must be contained, cooled, and extinguished in a controlled way. So that the gap between the contacts can again withstand the voltage in the circuit. Electric ratings:Â a. AC: up to 63A, AC230/400V, AC50/60Hz; b. DC: up to 63A, DC110V/1P, DC125V/2P; Application: for protection of circuits from over-load and short-circuit; and for infrequent making and breaking of circuits under normal operation conditions, as well; Standard: IEC/EN 60898.
Product Description : Modular Circuit Breakers - xC60. Breaking Capacity as per IEC 60947-2, Icn = 15kA, upto 40A, Higher Installation Life : Energy limitation class: 3, Tropicalization: T2 - relative humidity 95% at 55C. Higher performance by Low cost : Cascading. Increase system continuty : Discrimination. Reference Temperature of 50C as per IEC60947-2. Product Specification: Brand - Schneider Model Name - A9N2P01C Current Rating - 1A Pole - Two Pole Rated operational voltage - 100V - 125V DC, 240V AC 50/60 Hz, 380V - 415V AC 50/60 Hz Rated service breaking capacity - 6kA conforming to EN/IEC 60947-2, 100V - 125V DC, 7.5kA conforming to EN/IEC 60947-2. 380V - 415V AC 50/60Hz Curve code - C Nominal Frequency - 50Hz / 60Hz Mounting Type - Clip-on Weight (in kg) - 0.250 Warranty - 2yr (on manufacturing defect)
Miniature circuit breakers protect installations against overload and short-circuit, warranting reliability and safety for operations. They have two different tripping mechanisms, the delayed thermal tripping mechanism for overload protection and the magnetic tripping mechanism for short circuit protection. ï?? Extra-wide and complete range of MCBs to cover most applications and markets ï?? Meeting worldwide standards ï?? Certificates, documentation, training or background information to support customers due to their daily work ï?? Space and time saving thanks to frame degree updates Main features MCB range offer the possibility to select among different characteristics (B, C, D), configurations (1P, 1P+N, 2P, 3P, 3P+N, 4P), breaking capacities (up to 15 kA) and rated currents (up to 125A). Compliance to the worldwide standards, IEC/EN 60898-1 IEC/EN 60947-2 IEC/EN 60947-3 IEC/EN 61009-1 GB10963.1 GB1096.1 GB14048.2 GB14048.3 GB16917.1 Allowing the use for residential, commercial and industrial applications 25 mm2 and 10 mm2 cylinder lift twin terminals for challenging industrial use. Cross Real contact position indication, directly connected to the moving contact, for more comfort and safety ï?? Environmental Ambient Air Temperature: Operation -5 ... +55°C Storage -40 ... +70 °C Resistance to Shock acc. to IEC 60068-2-27: 30g / 2 shocks / 13 ms Resistance to Vibrations acc. to IEC 60068-2-6: 5g, 20 cycles at 5 ... 150 ... 5 Hz Environmental Conditions: 28 cycles with 55 °C / 90-96 % and 25 °C / 95-100 % Technical Standards: IEC/EN 60898-1 Rated Current (In): 6A, 10A,16A, 20A, 25A, 32A, 40A, 50A, 63A, 80A, 125A Rated Operational Voltage: acc. to IEC 60898-1 230 V AC & 400V AC Rated Insulation Voltage (Ui): acc. to IEC/EN 60664-1 440 V Rated Frequency (f): 50 Hz 60 Hz Rated Ultimate Short-Circuit Breaking Capacity (Icu): (230V AC & 400V AC) 15 kA Rated Service Short-Circuit Breaking Capacity (Ics): (230V AC & 400V AC) 6 kA Instantaneous release: Type C: Lighting protection ; Type D: Motor protection
Relay , Diodes , MCB Miniature circuit breakers, copper wire and cable , flood ( street light ) , motor starter , submersible cable .
NL7-63 Series DC Miniature Circuit Breaker: PV Series Circuit Breaker:NL7-63; Number of Poles:1P, 2P, 3P, 4P; Framedegree rated current (A):63; Ue Rated operating voltage (V DC):DC12V,DC24V,DC48V,DC80V,DC125V, DC250V,DC500V,600V,DC750V,DC800V,DC1000V,DC1200V; Rated Current In (A):6-10-16-20-25-32-40-50-63; Rated Impact voltage Uimp (kV):4; Ultimate breaking capacity Icu (kA):6; Run breaking capacity Ics (%Icu):75%; Mechanical durability:20000 cycles; Electrical durability:3000 cycles; Curve type:B,C,D.
Place of origin: Zhejiang, china (mainland) Brand name: Safesave Model number: Dz47-63 Type: Mini Poles number: 1p, 2p, 3p, 4p Color: White Current: 1-63a Certification: Ce/iso9001 Rated voltage: 230/400v Rated frequency: 50/60hz Standard: Iec60898-1 Mechanical life: 1000times Breaking capacity: 6ka
MCB 6A - 32A 1Pole Make: LS, Korea. 12.
Terasaki, , square d, siemens, merlin gerin, qo, areva, sylvania, westinghouse, ge, murray, moeller, federal, schneider, zinsco, eta, cutler hammer, airpax, heinemann, klixon, hager. Miniature circuit breaker, air circuit breaker, electric circuit breaker, earth leakage circuit breaker, thermal magnetic circuit breaker, low voltage circuit breaker, molded case circuit breaker, vacuum circuit breaker, standard circuit breaker
Mini circuit breaker Gkd-65 midget circuit breaker is mainly suitable for overload and short circuit of Distribute circuit and equipment within the circuit of ac50hz, rated voltage up to 400v, Current up to 63a. It can also be used for an unfrequent switchover of the circuit. Main technical parameter: 1. Feature of over current tripper 2. When the ambient temperature is 30¦--35¦, the over-current tripper feature should In line with the characteristic of table 1. 3. Breaking capacity: complies with standard of ie60898, gb10963 and gb 10000a.
Mini circuit breaker(dpn) Gkd-32 is mainly suitable for overload and short circuit protection Within the circuit of ac 50/60 hz, rated voltage of single pole 250v or down The item is the idealest distribution protective switch in the civil residence field At present. This product conforms to the requirement of iec60898 and gb10963 standard.
Dz47-63(c45n) series circuit breaker is used in lighting distribution system or motor distribution system for protecting overload and short circuit in the system. This circuit breaker is neoteric in structure, light in weight, reliable and excellent in performance. Its frame and parts adopt plastics of high fire resistant and shockproof. The product, with long life, is mainly used in ac 50hz/60hz single pole 240v or two, three, four poles up to 415v circuit for overload and short circuit protection, as well as for unfrequently switching on&off electric equipment and lighting circuit in normal case. The products comply with iec 60898 & gb10963-1999. Specification: Number of pole: 1, 2, 3, 4pole Rated voltage: 240/415ac Rated current: 1, 3, 6, 10, 16, 20, 25, 32, 40, 50, 63a Breaking capacity: 4.5/6ka Electrical endurance: 10, 000 times
òConstructed of super nylon. òIn front of the lockout,90¦curved mental hook sets on left and right respectively, used for plug in the two holes of power switch. òUsed for open circuit breaker or closed circuit breaker.
Ccb531n circuit breaker Vde approval circuit breaker Manufactured according to iec/en60898, gb10693. Pole:1p-n Rated voltage:230v~ Rated current:6, 10, 16, 20, 25, 32a Tripping characteristic: "b" "c" Breaking capacity: 6ka/ class3 12pcs/box. 120pcs/carton.
DZ47-63 Miniature Circuit Breakers has small size, light weight, novel structure and excellent performance. The material of enclosure and inside plastically parts is fire resistance and withstand shocking. It is used in the circuit of 50/60Hz,rated voltage 230/400 V, rated current up to 100A as protection against overload and short circuit. It is also used as protection against frequent switchover.
Circuit breaker Specifications: 1) rated current: 1a, 2a, 3a, 4a, 6a, 10a, 13a, 16a, 20a, 25a, 32a, 40a, 50a, 63a, 80a, 100a, 125a 2) rated short-circuit breaking capacity: 6ka, 4.5ka, 10ka 3) type of instantaneous tripping: b, c, d Packed in paper box Packed in paper box
Mini circuit breaker has novel structure , reliable performance, high breaking capacity, pleasing outlook and small size. Its case and items are adopted by high fireresistant and shockproof plastics, it mainly used in the building office, house and similar building for illuminating at ac 50hz(60 hz), rated voltage below 400v , rated current below 100 a, distribution circuit and equipment overload, short circuit protection .It can also be used for unfrequent switch over of the circuit under normal conditions .This product conforms to the requirement of iec 60898&gb 10963 standards. Miniature