LC1-D 3p Ac magnetic power contactor is mainly used in 50/60Hz electrical lines of the rated voltage up to 660V AC and rated current up to 370A,are applicable for remote making and breaking of electrical lines or frequent control of AC motors, having no-voltage protection. Usually, it can be combined with JR29 series thermal relay to form electromagnetic starters which have overload and open-phase protection. It complies with IEC947-4-1
CJT1 220V-380V air ac modular contactor is suitable for frequency 50HZ,rated insulation voltage up to 380V, rated operation current 10-150A. It is mainly used for making or breaking electric circuits at a long distance and for frequent starting and stopping and controlling AC motors. It is used in combination with thermal relay to compose a magnetic motor starter. The product accords with standard IEC 60947-4-1,GB14048.4
4P 60kA AC surge protector This surge protective device( hereinafter referred to as SPD) are suitable for AC 50/60Hz, rated voltage up to 380v IT,TT,TN-C, TN-S,TN-C-S and other power supply system, it protect to indirect and direct lightning effect or other transient over voltage SPD design according with GB18802.1/IEC61643-1 standard. Specification details: Model PQ1-60 Poles 4P Max. continious working voltage(Uc) 420V AC(can customized) Nominal discharge current(In) 30kA Max.discharge current(In) 60kA Voltage protection level(Up) 2.0kV Matched circuit breaker/Fuse 32A Response time
2P 80kA AC surge protector This surge protective device( hereinafter referred to as SPD) are suitable for AC 50/60Hz, rated voltage up to 380v IT,TT,TN-C, TN-S,TN-C-S and other power supply system, it protect to indirect and direct lightning effect or other transient over voltage SPD design according with GB18802.1/IEC61643-1 standard. Specification details: Model PQ1-80 Poles 2P Max. continious working voltage(Uc) 420V AC(can customized) Nominal discharge current(In) 40kA Max.discharge current(In) 80kA Voltage protection level(Up) 2.5kV Matched circuit breaker/Fuse 32A Response time
All the type of such as makita, dewalt, aeg As per request
Changeover switch We supply circuit breaker, meters, stabilizer, switch, relay, contactor, lamps Strong export carton
Ag, AgCu, AgNI, AgCdo, AgSNO2, AgSNO2In2O3, AgW, AgW+WC, AgC, CuW 50,000pcs/carton; not over 20KGS/CTN
Variable Vacuum Capacitor CKTB750/28/220 vacuum capacitor CKTB750/28/220 Cross reference Jennings Type: CVFP750-40S comet old type: CV2C-750E/40 comet new type: CVMA-750AC/40-AAB The CKTB750/28/220 capacitor use vacuum as dielectric with ceramic envelope ,which have the following features:High voltage , Small size , High Q value, Stabilization capability , High reliability ,Low price. The capacitor is Variable ceramic vacuum capacitors widely used in influence heating ,medium heating ,the equipments for communication transmitters and broadcasting etc.
Variable vacuum capacitor cktb500/10/100( Cktb500/10/100( vacuum capacitor cross reference Jennings type: csvf 500-0315 Comet old type: cv1c-500t/15 Comet new type: cvve-500ac/15-bca-m The cktb500/10/100( capacitor use vacuum as dielectric with ceramic envelope , which have the following features:high voltage , small size , high q value, stabilization capability , high reliability , low price. The capacitor is variable ceramic vacuum capacitors widely used in influence heating , medium heating , the equipments for communication
1. General HVJ5 1.14 kv 250A AC vacuum contactor is designed for long-distance making and breaking of circuit, frequent starting and controlling of AC motors in the power systems, with AC 50Hz-60Hz, rated voltage of 1140V and rated current to 250A. It also can be equipped with thermal relay and all kinds of protection apparatus like electromagnetic starter, especially applied to explosion-proof starter and so on. 2. Main technical parameter Rated voltage: 1140 v Control voltage: 36V, 110V, 220V, 380V Rated current: 250A Opening distance: 2±0.2 mm Over travel: 1±0.2 mm Final pressure: 30±3 N Main circuit power frequency voltage withstand: 4200 V Auxiliary circuit power frequency voltage withstand: 2500 V Control circuit power frequency voltage withstand: 2000 V Making capacity: 10Ie,100 times Breaking capacity: 8Ie,25 times Limit breaking current(A): 4500,3 times Electricity life times AC3: 60*104 Electricity life times AC4: 60*104 Mechanical life times: 300*104 Overload capacity: 8Ie 10S Remark: “Ie” is Rated current of main circuit.
1. General HVJ5 1.14 kv 1000A AC vacuum contactor is designed for long-distance making and breaking of circuit, frequent starting and controlling of AC motors in the power systems, with AC 50Hz-60Hz, rated voltage of 1,140V and rated current to 1000A. It also can be equipped with thermal relay and all kinds of protection apparatus like electromagnetic starter, especially applied to explosion-proof starter and so on. 2. Main technical parameter Rated voltage: 1140 V Control voltage: 36 V, 110 V, 220 V, 380 V Rated current: 1000A Opening distance: 2±0.2 mm Over travel: 1±0.2 mm Final pressure: 30±3 N Main circuit power frequency voltage withstand: 4200 V Auxiliary circuit power frequency voltage withstand: 2500 V Control circuit power frequency voltage withstand: 2000 V Making capacity: 10Ie,100 times Breaking capacity: 8Ie,25 times Limit breaking current(A): 10000,3 times Electricity life times AC3: 60*104 Electricity life times AC4: 1.5*104 Mechanical life times: 300*104 Overload capacity: 8Ie 10S Remark: “Ie” is Rated current of main circuit.
1. Introduction JCZ5 7.2 kv vacuum contactor HVJ6-7.2 series indoor high-voltage AC vacuum contactor has two types: One is Mechanical holding type, the other is Electromagnetic holding type. It is applicable for three-phase AC 50HZ power system of rated voltage 7.2KV and below and rated current up to 630 A to open and close circuit remotely and control electrical equipment like high-voltage motor, transformer and capacitive load. It is especially suitable for fields operated frequently. The contactor uses the international fashionable up and down structure arrangement and has the advantages of small, light, easy to maintain and form a complete set of F-C circuit equipment. 2. Service condition a) Ambient air temperature: -25?- +40?. b) Altitude not exceed 2000m c)Humidity: -Relative humidity: daily mean not higher than 95?,monthly mean not higher than 90?; -Aqueous vapor pressure: daily mean not exceed 2.2 KP, monthly mean not exceed 1.8 KP Ambient air should not be obviously polluted by corrosive or flammable gas or vapor; C)Free of frequent severe vibration; When running, angle of inclination between installation surface and horizontal plane should not exceed 5?. Main technical parameters Rated voltage: 7.2 kv Control voltage: 110V, 220V Rated current: 200A, 400A, 630A Contacts separation: 4.5+1-0.5mm Over travel: 1.5±0.5 mm Main circuit power frequency voltage withstand: 32000 V Auxiliary circuit power frequency withstand voltage: 2500 V Control circuit power frequency withstand voltage: 2000 V Making capacity: 10le,100 times Breaking capacity: 8le, 25 times Limit breaking current(A): 10le Mechanical life times: 30×104 Weight: 28KG
1. CJX2-K LC1-K Three Phase ac mini contactor is suitable for use in the circuit up to the rate and frequent starting, controlling the AC motor. 2. The addition of auxiliary contact group to the contactor, combined with the proper thermal relay, can act to protect the circuit bound to overload. 3. The LC1-K Series AC Contactor complies with IEC947-2,VDE0660 and BS5452 .
CJX2-N LC1-N ac mechanical interlock contactor is suitable for using in the circuits up to the rated voltage 660V AC 50/60Hz, current 620A, for convertible controlling the motor. This mechanical interlocking device ensures contact changeover of the two convertible contactors. It conforms to IEC60947-4-1
Npb series busduct 1.Current ratings up to 6800a; voltage ratings up to 35kv 2.Transport ac or dc for generator, transformer, station branch circuit and substation etc. 3.Rectangular conductor or groove conductor, housing of aluminum, a- alloy or weak magnetic plate
Electrical contactors.
Electrical contactor, contactors.
HLC series definite purpose contactors (1-pole, 2-pole, 3-poleand 4-pole , 20-40a ) are ideal for hvac, air conditioning, refrigeration, heating, data processing, welding, elevators, hoists & cranes, lighting, pools & spas and food service equipment.
Breaker (MCB, MCCB, RCCB, ELCB), Ac contactor, Relay, electrical accessories, Industry plug, socket & coupings, Bell, Surge protective device ( PD), Residual current device (RCD).
Contactor , mccb , mcbs.