UK Series split-core current transformer has been specially designed to facilitate their installation in new or already existing networks. They may be installed without opening any cable or bus-bar circuit.An internal precision resistor across the secondary winding of the CT provides a low safe voltage output.It can save time and the installations costs. Features Doubie-screw fastening,safe,easy to install,portable. Wide inner window,allowing clamping of big cables or bus-bars. Wide range of sizes to accommodate all the existing installations. Application Current measurement,monitoring and protection for electrical wiring and equipment. Current and power measurement for electric motors,lighting,air compressor,heating and ventilation system,air-condition equipment and automation-control system. Current,power and energy monitoring device. Relay protection device
Epoxy Potting,Double-screw fastening,safe,easy to install,portable. Wide inner window,allowing clamping of big cables or bus-bars. Wide range of sizes to accommodate all the existing installations. Conforms to IEC185,BS7626,BSEN60044-1 and IEC60044-1.
Epoxy Potting,Double-screw fastening,safe,easy to install,portable. Wide inner window,allowing clamping of big cables or bus-bars. Wide range of sizes to accommodate all the existing installations. Conforms to IEC185,BS7626,BSEN60044-1 and IEC60044-1.
Ratio 1000: 1 or 2000:1 (customized) Accuracy class 0.2%, 0.5%, 1% Primary current 0 - 3000A AC Secondary current 0 - 5A AC (customized) Max. Cont. Input current 3600A Over voltage category CAT III 600 V Output signal (AC current) 500mA,1A,5A AC at nominal input current Output signal (AC voltage) 333mV,500mV,1V,5V AC at nominal input current Frequency range 40Hz-2000Hz Dielectric strength 3KV 50Hz/60Hz at 1 minute Temperature range -20C to +55C Output 2.5 meter cable with D01 connector Max. voltage not insulated conductors 600 V Standard EN 61010-1, EN 61010-2-032, IEC60044-1 Installation Clamp type Output mode Lead output(2.5m) Mechanical parameters Dimensions (L x W x H) (mm) 116 x 327 x 35 Weight (g) 1200 Holding wire diameter (mm) 120 x 50 Max. jaw opening (mm) 50 Jaw Color White Material PC+ABS+Polycarbonate, UL94 V0
Technical parameters Standards IEC60044-1; IEC 61869-2; NTC 2205; ANSI C57.13; GB1208-2006 Rated primary current 500-1500A Rated load 20VA Rated frequency 50Hz or 60Hz Rated secondary current 5A or 1A Rated short-time thermal current 40kA, 1S Rated continuous thermal current 120%I1n Secondary winding power-frequency voltage 3kV, 1min Instrument security factor FS10 Mechanical parameters Dimensions (WDH) (mm) 120x185x100 Weight (kg) 7 Operating conditions Operating temperature -35C to +55C Daily average temp
FEATURES Most cost-effective Faster installation Safe and easy installations High accuracy 0.5 Holding wire diameter: �?16mm Measurement range of 1mA to 200A AC Low phase shift for power measurement Output model: Lead output(2.5m) Isolated plastic case recognized according to UL94-V0 Small-size, compact size, light-weight Over-Voltage protection circuit is installed. CE, UL / EN 61010 - 1 certified PARAMETERS Technical parameters Standards IEC/EN60044-1 & IEC61010-1 & IEC61869-2&ANSI C57.13 Ratio 1000: 1 or 2000:1 , customized Nominal input current Primary current 20A/30A/40A/50A/60A/80A/100A/150A/200A Overload withstand 1.2 times rated current continuously Accuracy 0.2%, 0.5 %, 1% System Voltage 720V(0.72kV) Output signal 10mA-200mA AC optional 333mV AC or 100mV-2V optional Frequency range 40 Hz-500 Hz Dielectric strength 3KV 50Hz/60Hz at 1 minute Output Standard 2.5 meter cable Protection Level 3.0V0-P Installation Category CAT or CAT 600VAC Max. jaw opening 16 mm Mechanical parameters Dimensions (WDH) (mm) 38mm 55mm 18mm Weight(g) 60 Operating conditions Operating temperature -25C to +55C Relative Humidity 0-85% non-condensing Altitude
Technical parameters Standards IEC60044-1; IEC 61869-2; NTC 2205; ANSI C57.13; GB1208-2006 Rated primary current 100-1500A Rated load â?¤10VA Rated frequency 50Hz or 60Hz Rated secondary current 5A or 1A Rated short-time thermal current 40kA, 1S Rated continuous thermal current 120%I1n Secondary winding power-frequency voltage 3kV, 1min Instrument security factor FS10 Mechanical parameters Dimensions (WDH) (mm) 80x110x50 Weight (kg) 2.1 Operating conditions Operating temperature -35C to +55C Daily average temp
FEATURES Most cost-effective Faster installation Safe and easy installations High accuracy 0.5 Holding wire diameter: 32mm Ratio ranging from 60/1A to 600/5A CE, UL PARAMETERS Technical parameters Standards IEC/EN60044-1 & IEC61010-1 & IEC61869-2&ANSI C57.13 Ratio 400: 5 or 200:5 , customized Nominal input current Primary current 100A/150A/200A/300A/400A/500A/600A Overload withstand 1.2 times rated current continuously Accuracy 0.2%, 0.5 %, 1%/60Hz System Voltage 720V(0.72kV) Output signal 1A or 5A 333mV AC or 100mV-2V optional Burden 2.5VA Frequency range 40 Hz-500 Hz Dielectric strength 3KV 50Hz/60Hz at 1 minute Output Standard 2.5 meter cable Max. jaw opening 32 mm Mechanical parameters Dimensions (DH) (mm) 110mm130mm 41mm Weight(g) 700 Operating conditions Operating temperature -25 C to +55 C Relative Humidity 0-85% non-condensing Altitude
Standards IEC60044-1; IEC 61869-2; ANSI C57.13; NTC 2205; GB1208-2006 Rated primary current 30-1000A Rated load 20VA Rated frequency 50Hz or 60Hz Rated secondary current 5A or 1A Rated short-time thermal current 40kA, 1S Rated continuous thermal current 120%I1n Secondary winding power-frequency voltage 3kV, 1min Instrument security factor FS 10 Mechanical parameters Dimensions (WDH) (mm) 45x120x65 Weight (kg) 2.1 Operating conditions Operating temperature -35C to +55C Daily average temp
Standards IEC60044-1; IEC 61869-2; ANSI C57.13; NTC 2205; GB1208-2006 Accuracy Class 0.5%, 1% Range of primary rated current 300-3000A Range of Rated load 25VA Rated frequency 50/60Hz Rated secondary current 5A or 1A Secondary winding power frequency withstand voltage 3kV, 1min Safety Factor Rating (FS)
Standards IEC60044-1; IEC 61869-2; ANSI C57.13; NTC 2205; GB1208-2006 Rated primary current 300-600A Rated load 10VA Rated frequency 50Hz or 60Hz Rated secondary current 5A or 1A Rated short-time thermal current 40kA, 1S Rated continuous thermal current 120%I1n Secondary winding power-frequency voltage 3kV, 1min Instrument security factor FS 10 Mechanical parameters Dimensions (WDH) (mm) 50x110x32 Weight (kg) 1 Operating conditions Operating temperature -35C to +55C Daily average temp
Technical parameters Standards IEC60044-1; IEC 61869-2; ANSI C57.13; NTC 2205; GB1208-2006 Rated primary current 20-600A Rated load 25VA Rated frequency 50Hz or 60Hz Rated secondary current 5A or 1A Rated short-time thermal current 40kA, 1S Rated continuous thermal current 120%I1n Secondary winding power-frequency voltage 3kV, 1min Instrument security factor FSâ?¤10 Mechanical parameters Dimensions (WDH) (mm) 50x110x105 Weight (kg) 3.1 Operating conditions Operating temperature -35C to +55C Daily average temp
Split core Current transformer: 1) HK-23: Inner hole 20*30mm, Ratio: 100/5A, 150/5A, 200/5A, 250/5A, 300/5A, 400/5A 2) HK-58: Inner hole 50*80mm, Ratio: 250/5A, 300/5A, 400/5A, 500/5A, 600/5A, 750/5A, 800/5A, 1000/5A 3) HK-812: Inner hole 80*120mm, Ratio: 500/5A, 600/5A, 750/5A, 800/5A, 1000/5A, 1200/5A, 1250/5A, 1500/5A, 1600/5A, 2000/5A, 2500/5A, 3000/5A, 4000/5A 4) HK-816: Inner hole 80*160mm, Ratio: 1000/5A, 1200/5A, 1500/5A, 1600/5A, 2000/5A, 2500/5A, 3000/5A, 4000/5A, 5000/5A, 6000/5A, 7500/5A, 8000/5A
1:The structure of the self-locking, safe, easy to install, portable 2:Wide inner window, allowing clamping of big cables or bus-bars 3:Wide range of sizes to accommodate all the existing installations 4:Isolated plastic case recognized according to UL94-V0 5:Wires plugs,Audio plugs,Power plugs and so on five kinds of plugs 1:Current measurement, monitoring and protection for electrical wiring and equipment. 2:Current and power measurement for electric motors, lighting, aircompressor,heating and ventilation system, air-condition equipment and automation – control system. 3:Current, power and energy monitoring device. 4:Relay protection device.
RCS series of frequency conversion for current transformer is develop by our company and the well-known research institute after many years of cooperation.The product has the characteristics of current can be measured in real time, fast response, not saturated and almost no phase error, so it can applies to large current situation such as variable frequency speed control, relay protection, silicon controlled, resistance welding and electric furnace, short-circuit test, lightning signal acquisition and so on. The product output is the AC voltage signal which is proportional to the measured current, output no longer connected sampling resistor circuit.The product is the traditional transformer and Holzer transformer ideal substitute products. High linearity Wide dynamic range No danger from open-circuited secondary Not damaged by large overloads No magnetic hysteresis/No magnetic saturation Low consumption and low thermal losses. Rated current(rms) : 200A Rated output(Full scale FS): 4Vrms Output limit: 300%FS Operating temperature range -25J to +70J Bandwidth: 1Hz to 100kHz Phase shift: 900.1 degrees Accuracy: 0.3% of reading(5% to 150% FS,25J) Temperature Sensitivity : 0.05% per C.
YTB series of frequency conversion for current transformer is develop by our company and the well-known research institute after many years of cooperation.The product has the characteristics of current can be measured in real time,fast response,not saturated and almost no phase error,so it can applies to large current situation such as variable frequency speed control, relay protection,silicon controlled, resistance welding and electric furnace, short-circuit test,lightning signal acquisition and so on. The product output is the AC voltage signal which is proportional to the measured current, output no longer connected sampling resistor circuit.The product is the traditional transformer and Holzer transformer ideal substitute products. High linearity Wide dynamic range No danger from open-circuited secondary Not damaged by large overloads No magnetic hysteresis/No magnetic saturation Low consumption Low thermal losses.
Detailed Product Description 1. Manufactory and trading company 2. Stable product performance 3. Plywood containers 4. Offshore delivery within 10 days Performance characteristic: Has a high saturation flux density, pulsed magnetic permeability, low core loss, coercive force, frequency range in the 1 ~ 100 KHz. Application: High-power switching power supply and inverter welding inverter power transformer UPS uninterruptible power supply Communications equipment High frequency induction Heating power supply Charging power supply 40/65*15 40/65*25 40/70*25 40/73*30 40/75*40 40/78*25 40/85*30 41.5/47.5*5 41/77*36 42/65*30 42/68*35 42/70*30 42/72*25 42/73*38 43.5/53.5*5 43.5/53.5*8 43/49*10 43/57*15 43/57*8 43/58*5 44/52.2*6.5 44/66*30 44/68*20 44/69*30 44/80*45 44/90*50 45/55*40 45/60*20 44/76*18 44/78*38 45/62*26 45/63*25 45/65*30 45/67*26 45/68*25 45/75*20 45/75*35 45/78*30 45/85*50 46.5/63*15 46/55*16 46/63*35 46/66*25 46/66*35 46/74*26 47/58*15 47/58.2*12 47/65*26 48/78*30 48/78*40 48/85*35 48/91*35 49.9/61.8*5.5 50/100*25 50/100*25 50/105*45 50/60*10 50/60*8 50/60*9 50/65*25 50/65*8 50/67*35 50/75*25 50/75*25 50/80*10 50/80*15 50/80*25 50/80*25 50/90*30 50/90*30 51/64*26 52.5/60*6.5 52.5/61*6.5 52/62*8 53/64*10 54/60*6.5 54/62*10 54/80*25 55/62*5 55/65*10 55/69*30 56/70*25 57.5/65*7.5 58/78*30 58/82*30 59/70*25 60/120*30 60/120*30 60/75*25 60/80*16 60/80*30 60/90*20 61/69*10 61/69*5 61/70*10 61/70*20 61/70*20 62/71*8 62/78*30 64/75.2*5 64/77*4 64/78*30. Wooden case+carton box.
Application areas: Measuring-level current transformer used in power system, transformer used on precision measuring instruments (such as watt-hour meter). According to the requirements of different measurement accuracy of the transformer, different soft magnetic materials can be chosen as iron core materials. The higher the permeability of the iron core is, the smaller the measurement error of the transformer is, hence the accuracy is higher. At present, the most common iron core material is cold-rolled silicon steel sheet, followed by Permalloy and nano-crystalline glass alloy. In recent years, demands for transformers with high-precision level (such as class 0.2, class 0.2Sand class0.5S) increased rapidly. When small ratio, low ampere turns are required or the iron core is restricted because of the small volume, the cold-rolled silicon steel often fails to meet the accuracy requirements. Although the Permalloy iron cores with high permeability can meet the required precision, its price is very high. However use of nano-crystalline alloy iron cores can both meet the accuracy requirements and be produced at lower cost than the Permalloy. Therefore, the demand of measuring level current transformer iron core made of nano-crystalline alloy rapidly increased domestically. The typical parameters comparison of the common soft magnetic materials used for current transformer iron cores: Basic parameters Nano-crystalline iron core Permalloy (1J85) iron core Silicon steel iron core Saturation magnetic flux density (Bs) 1.25T 0.75T 2.03T Initial permeability (¦Ì0) 8¡«12, 104 5¡«8, 104 103 Maximum permeability (¦Ìm) 60, 104 60, 104 4, 104 Curie Temperature (¡æ) 570 400 740 Density (g/cm3) 7.25 8.75 7.65 Lamination factor 0.7 0.9 0.95 Thickness (mm) 0.03 0.15 0.3 Features: It is made of the iron-based nano-crystalline strips with a moderate saturation magnetic induction, high permeability and low loss, which can effectively reduce ratio difference angle difference of the transformer. The saturation magnetic induction Bs of nano-crystalline alloy is between the silicon steel and Permalloy. The lower the Bs value is, the lower the security coefficient of the instrument is. When the system failure occurs and large current through the current transformer results therefore, the iron core is more easily filled, and the secondary current no longer increases in proportion, as can assure that the secondary instruments are well protected and not to be damaged. Permeability of nano-crystalline alloy is close to Permalloy and a magnitude higher than silicon steel, so it is suitable to be made as high-precision transformer iron core. The density and lamination coefficient of nano-crystalline is lower than that of Permalloy, under the condition of the same size and similar performance of the two. In this case the nano-crystalline iron core is 1/4 lighter in weight, and 1/3 lower in the manufacturing cost. In addition, the linear range of nano-crystalline alloy is wider than that of Permalloy .It can work for a long time at temperature of -55 ~ 130 ¡æ ,with a good temperature stability. Specifications a. Rectangular core: (mm) Iron Core Size(mm) (mm) The case size(mm) Weight of the iron Core (kg per piece) Turns Ratio N1: N2 Excitation current(mA) Excitation voltage(mV) 55*97/77*119, 25 50*92/82*114, 30 0.53 1:1 25 0.45 95 2.2 1500 53 70*90/100*120, 30 65*85/105*125, 36 0.81 1:1 200 15 1:1 500 50 75*95/105*125, 25 70*90/110*130, 30 0.7 1:1 70 2 1:1 175 8 80*95/120*135, 25 75*90/125*140, 30 1.09 1:1 80 1.7 1:1 600 41 90*90/160*160, 30 85*85/165*165, 36 2.4 1:1 100 6 1:1 500 100 1:1 1000 140 135*135/260*260, 10 130*130/265*265, 16 2.3 1:1 100 1.5 1:1 500 32 82*602/138*658, 45 75*595/145*665, 55 8.8 1:1 100 1.2 1:1 1000 45 1:1 2000 120 Note: Iron cores of other specifications can be provided upon request of users b. Ring core: No. The iron Core Size Case size(mm) The weight of the iron core (kg per piece) Turns ratio N1: N2 is 1:1; Input current (mA), 50Hz; Output voltage (mV) 1 1105/1165, 15 1095/1175, 25 8.35 Excitation current 450 1200 2000 Excitation voltage 0.59 2.36 5.28 2 415/520, 15 409/526, 23 6.08 Excitation current 50 250 700 Excitation voltage 0.4 3 11 3 305/490, 15 299/496, 23 9.1 Excitation current 350 900 ¡¡ Excitation voltage 5 20 ¡¡ 4 315/395, 35 309/401, 43 8.2 Excitation current 120 400 ¡¡ Excitation voltage 3 11 ¡¡ 5 198/248, 30 192/254, 37 2.76 Excitation current 100 200 500 1000 Excitation voltage 2 6 35 90 6 198/248, 20 192/254, 27 1.84 Excitation current 100 200 500 1000 Excitation voltage 1.5 3.5 25 60 7 155/200, 30 150/205, 36 2 Excitation current 100 190 1000 Excitation voltage 2.5 9.5 80 8 140/180, 30 135/185, 36 1.58 Excitation current 40 80 240 Excitation voltage 1 2.9 15 9 130/190, 30 125/195, 36 2.38 Excitation current 40 80 240 Excitation voltage 1.2 3.8 17 10 100/140, 30 95/145, 36 1.19 Excitation current 30 120 500 Excitation voltage 0.85 6.8 68 11 90/130, 30 85/135, 36 1.09 Excitation current 30 120 500 Excitation voltage 0.7 6 55 12 90/125, 25 85/130, 31 0.78 Excitation current 30 120 500 Excitation voltage 0.9 7 70 13 80/120, 30 75/125, 36 0.99 Excitation current 200 500 ¡¡ Excitation voltage 20 65 ¡¡ 14 85/115, 30 80/120, 36 0.74 Excitation current 30 120 500 Excitation voltage 0.7 6.5 55 15 85/125, 20 80/130, 26 0.7 Excitation current 30 120 500 Excitation voltage 0.62 5.5 50. wooden case+carton box.
Application areas: Measuring-level current transformer used in power system, transformer used on precision measuring instruments (such as watt-hour meter). According to the requirements of different measurement accuracy of the transformer, different soft magnetic materials can be chosen as iron core materials. The higher the permeability of the iron core is, the smaller the measurement error of the transformer is, hence the accuracy is higher. At present, the most common iron core material is cold-rolled silicon steel sheet, followed by Permalloy and nano-crystalline glass alloy. In recent years, demands for transformers with high-precision level (such as class 0.2, class 0.2Sand class0.5S) increased rapidly. When small ratio, low ampere turns are required or the iron core is restricted because of the small volume, the cold-rolled silicon steel often fails to meet the accuracy requirements. Although the Permalloy iron cores with high permeability can meet the required precision, its price is very high. However use of nano-crystalline alloy iron cores can both meet the accuracy requirements and be produced at lower cost than the Permalloy. Therefore, the demand of measuring level current transformer iron core made of nano-crystalline alloy rapidly increased domestically. The typical parameters comparison of the common soft magnetic materials used for current transformer iron cores: Basic parameters Nano-crystalline iron core Permalloy (1J85) iron core Silicon steel iron core Saturation magnetic flux density (Bs) 1.25T 0.75T 2.03T Initial permeability (¦Ì0) 8¡«12, 104 5¡«8, 104 103 Maximum permeability (¦Ìm) 60, 104 60, 104 4, 104 Curie Temperature (¡æ) 570 400 740 Density (g/cm3) 7.25 8.75 7.65 Lamination factor 0.7 0.9 0.95 Thickness (mm) 0.03 0.15 0.3 Features: It is made of the iron-based nano-crystalline strips with a moderate saturation magnetic induction, high permeability and low loss, which can effectively reduce ratio difference angle difference of the transformer. The saturation magnetic induction Bs of nano-crystalline alloy is between the silicon steel and Permalloy. The lower the Bs value is, the lower the security coefficient of the instrument is. When the system failure occurs and large current through the current transformer results therefore, the iron core is more easily filled, and the secondary current no longer increases in proportion, as can assure that the secondary instruments are well protected and not to be damaged. Permeability of nano-crystalline alloy is close to Permalloy and a magnitude higher than silicon steel, so it is suitable to be made as high-precision transformer iron core. The density and lamination coefficient of nano-crystalline is lower than that of Permalloy, under the condition of the same size and similar performance of the two. In this case the nano-crystalline iron core is 1/4 lighter in weight, and 1/3 lower in the manufacturing cost. In addition, the linear range of nano-crystalline alloy is wider than that of Permalloy .It can work for a long time at temperature of -55 ~ 130 ¡æ ,with a good temperature stability. Specifications a. Rectangular core: (mm) Iron Core Size(mm) (mm) The case size(mm) Weight of the iron Core (kg per piece) Turns Ratio N1: N2 Excitation current(mA) Excitation voltage(mV) 55*97/77*119, 25 50*92/82*114, 30 0.53 1:1 25 0.45 95 2.2 1500 53 70*90/100*120, 30 65*85/105*125, 36 0.81 1:1 200 15 1:1 500 50 75*95/105*125, 25 70*90/110*130, 30 0.7 1:1 70 2 1:1 175 8 80*95/120*135, 25 75*90/125*140, 30 1.09 1:1 80 1.7 1:1 600 41 90*90/160*160, 30 85*85/165*165, 36 2.4 1:1 100 6 1:1 500 100 1:1 1000 140 135*135/260*260, 10 130*130/265*265, 16 2.3 1:1 100 1.5 1:1 500 32 82*602/138*658, 45 75*595/145*665, 55 8.8 1:1 100 1.2 1:1 1000 45 1:1 2000 120 b. Ring core: No. The iron Core Size Case size(mm) The weight of the iron core (kg per piece) Turns ratio N1: N2 is 1:1; Input current (mA), 50Hz; Output voltage (mV) 1 1105/1165, 15 1095/1175, 25 8.35 Excitation current 450 1200 2000 Excitation voltage 0.59 2.36 5.28 2 415/520, 15 409/526, 23 6.08 Excitation current 50 250 700 Excitation voltage 0.4 3 11 3 305/490, 15 299/496, 23 9.1 Excitation current 350 900 ¡¡ Excitation voltage 5 20 ¡¡ 4 315/395, 35 309/401, 43 8.2 Excitation current 120 400 ¡¡ Excitation voltage 3 11 ¡¡ 5 198/248, 30 192/254, 37 2.76 Excitation current 100 200 500 1000 Excitation voltage 2 6 35 90 6 198/248, 20 192/254, 27 1.84 Excitation current 100 200 500 1000 Excitation voltage 1.5 3.5 25 60 7 155/200, 30 150/205, 36 2 Excitation current 100 190 1000 Excitation voltage 2.5 9.5 80 8 140/180, 30 135/185, 36 1.58 Excitation current 40 80 240 Excitation voltage 1 2.9 15 9 130/190, 30 125/195, 36 2.38 Excitation current 40 80 240 Excitation voltage 1.2 3.8 17 10 100/140, 30 95/145, 36 1.19 Excitation current 30 120 500 Excitation voltage 0.85 6.8 68 11 90/130, 30 85/135, 36 1.09 Excitation current 30 120 500 Excitation voltage 0.7 6 55 12 90/125, 25 85/130, 31 0.78 Excitation current 30 120 500 Excitation voltage 0.9 7 70 13 80/120, 30 75/125, 36 0.99 Excitation current 200 500 ¡¡ Excitation voltage 20 65 ¡¡ 14 85/115, 30 80/120, 36 0.74 Excitation current 30 120 500 Excitation voltage 0.7 6.5 55 15 85/125, 20 80/130, 26 0.7 Excitation current 30 120 500 Excitation voltage 0.62 5.5 50. wooden case+carton box.
Detailed Product Description 1.CT-1000 2.Droop Current Transformer 3.Primary Current 4.ISO9001 CERTIFICATED 5.IN STOCK CT-1000 Droop Current Transformer Specifications of CT-1000 Model CT-1000 Primary Current 1000A Secondary Current 0.37A Mounting hole size ¦µ13 Power Range 750KVA~1250KVA. Minimum Order Quantity: 1 Piece/PiecesTrial Order Port: Shanghai CHINA Packaging Details: Individual packing and standard export cartons Measurement of Inner packing10cmx9cmx10cm Delivery Time: within 3-5 days after payment Payment Terms: T/T,Western Union Supply Ability: 500 Piece/Pieces per Month.