Nominal Current(RMS):50/100/200/300/400/600A Vout@Ipn:+_4.000V Measuring Range:0~+_900A Supply Voltage DC:+_12-15 Accurancy@Ipn,+25degree Celsius:less than +_1.0% Mounting(mm):10.5*20.5
Nominal Current(RMS):10/25/50/75A Vout@Ipn:2.500+_0.625V Measuring Range:0~+_150A Supply Voltage DC:+5V Accurancy@Ipn,+25degree Celsius:less than +_0.5% Mounting(mm):8.2 in diameter
The CT can be mounted to existing panels, such as control centers of load centers, to measure or monitor wattage. These XTs can be mounted without removing existing cables for easier installation.
Nominal Current(RMS):200/400/800/1000/1200/2000A Vout@Ipn:+_4.000V Measuring Range:0~+_3000A Supply Voltage DC:+-12-15V Accurancy@Ipn,+25degree Celsius:less than +_0.5% Mounting(mm):12.5*41.0
Nominal Current(RMS):25/50/75/100A Vout@Ipn:+_25/50V Measuring Range:0~+_150A Supply Voltage DC:+-12-15V Accurancy@Ipn,+25degree Celsius:less than +_0.5% Mounting(mm):7.0*12.7  * Closed- loop                                        * Supply voltage: DC +-12~15V  * Capable measurement of currents: DC, AC,pulse with galvanic isolation between primary circuit and secondary circuit.
Specifications: Basic accuracy: 0.5%; Supply voltage: +12V, +15V, +24V, 220V Input current range: AC 1ï½?30A Frequency range: 50ï½?3000Hz Output: 0-5V, 0-10V, 0-20mA, 4-20mA Operating temperature: -10â??ï½?+60â?? Load of output: Voltage outputâ?¥2KΩï¼?Current outputâ?¤250Ω Static power: â?¤0.3W Rated power: â?¤0.7W Load of insulation voltage: DC 2500V Response time: â?¤300ms Thermal drift: â?¤300PPm/â?? Lightening surge: Power source end: 2000V; Input end: 10000A; Output end: 500V; Case style: E. Case material: ABS (flame retardant). Installation: 35mm DIN rail. Dimensions: Length: 116mm; Width: 25mm; Height: 87mm; Window diameter: Ï?6.2mm
Basic accuracy: 0.5. Power supply: +12V, +15V, +24V, 220V Input voltage range: AC 1ï½?30A Input frequency: 50ï½?3000Hz Output signal: 0-5V, 0-10V, 0-20mA, 4-20mA Operating temperature: -10â??ï½?+60â?? Load of output: Voltage outputâ?¥2KΩï¼?current outputâ?¤250Ω Static power: â?¤0.5W Rated power: â?¤1W Load of insulation voltage: DC 2500V Response time: â?¤300ms Thermal drift: â?¤300PPm/â?? Lightening sure: Power end 2000Vï¼?input end 10000Aï¼?output end 500V Case style: E. Case materials: ABS flame retardant. Installation: 35mm DIN rail.
Basic accuracy: 0.5. Power supply: +12V, +15V, +24V, 220V Input current range: AC 1ï½?30A Input frequency: 50ï½?3000Hz Output signals: 0-5V, 0-10V, 0-20mA, 4-20mA Operating temperature: -10â??ï½?+60â?? Load of output: Voltage Output â?¥2KΩ: Current outputâ?¤250Ω Static power: â?¤0.5W Rated power: â?¤1.5W Load of insulation Voltage: DC 2500V Response time: â?¤300ms Thermal drift: â?¤300PPm/â?? Lightening surge: Power end 2000V, input end 10000A, output 500V. Case style: E. Case materials: ABS (flame retardant). Installation: 35mm DIN rail.
Series: ce-ij03 Ce-ij03a(true rms) Input range: 0.5a~300a Output: 5v or 4-20 ma Accuracy: 0.2% or 0.5% Response time: 300 ms Power source: +12v or +15v or +24v Load capability: voltage outputú5ma Current outputú300w Quiescent power consumption: 200 mw L*w*h=83mm*36mm*56mm
Nominal current(rms):50/100/200/300/400/600a Voutipn:+4.000v Measuring range:0~+900a Supply voltage dc:+15v Accurancyipn, +25degree Celsiusless than1.0% Mounting(mm):10.5*20.5 * open- loop supply voltage: dc +15.0v * capable measurement of currents: dc, ac, pulse with galvanic isolation between primary circuit and secondary circuit.
Accuracy: 0.2; Aux. power: +12V, +24V, 220V Input range: AC 1ï½?30A Output signal: RS-485,MODBUS_RTU/ RS-232 MODBUS_RTU. Operating temperature: -10â??ï½?+60â?? Baud rate: 200, 2400, 4800, 9600ï¼?defaultï¼?, 19200, 38400, 57600bpsã?? Data type: â??n,8,1â?�ï¼?default, â??n,8,2â?�, â??e,8,1â?�, â??o,8,1â?� RS485 node: 64 Static Power: â?¤0.5W Rated Power: â?¤0.5W Load of Insulation Voltage: DC 2500V Response Time: â?¤500ms, 100ms (default) Thermal Drift: â?¤300PPm/â?? Lightening Surge: Aux. Power end 2000V, Input end 10000A, output end 500V; Case style: E. Case material: ABS flame retardant; Installation: 35mm DIN Rail standard;
Nominal Current(RMS):30/300A Vout@Ipn:2.500+_2.000V Measuring Range:+_30/+_300A Supply VoltaIpn,+25
3-phase4-wire AC Digital Transducer Product: 3-phase 4-wire ac multi-parameter digital transducer 1. Series: Ce-aj42-1----- 3-phase 4-wire, rs-485 interface, treble isolated (n case style only). Ce-aj42-2----- 3-phase 4-wire, rs-232c interface, treble isolated (n case style only). 2.Specifications: Input (measuring range)------ ac 45-65hz, voltage: 110v, 220v, 380v and 500v(or specially supply to meet user's other special requirement), current: 1a, 5a, 15a, 25a (or specially supply to meet user's other special requirement) Data output------rms of voltage ua, ub and uc; rms of current ia, ib and ic. Real value of frequency f. Other five parameters including active power p, reactive power q, power factor cosf, active energy and reactive energy are shown in the form of a percentage of the maximum value of its measurable range. Output interface------rs-485: two-wire connection, communication distance:1200m, +/- 15kv esd protection. Rs-232c: n case style connects directly through its terminals. Accuracy grade------ frequency: 0.05 hz. Voltage, current, power factor, active power, reactive power, active energy, reactive energy: 0.5%. (accuracy and linearity are ignored when the voltage is below 5%.) Baud rate------ 1200, 2400, 4800, 9600, 19.2k bps Refreshing period------ 250ms Isolation voltage------ 1000 v dc or 2500v dc Power consumption------
GANZ current transformers meet the highest international quality standards with more than 50 years of experience in industry.
Current transducer, voltage transducer, power transducer, frequency transducer, offside alarm transducer, insulator, current sensor, voltage sensor..
Transducers, hall effect current transducer, true rms transducer, self-powered transducer, multi-parameter digital transducer.
Split core current transformer, current transformer, current transducer, hall effect current sensor, hall effect voltage sensor.
Rated Input Current:5A Rated Output Current:2.5mA Turns ratio:2000:1 Phase Angle Error:less than 20'(1A,100) Linear Range:0~20A(100) Mounting(mm):D5.0 * Small size * High accuracy * Good consistency * Used for current and power measurement
Electropneumatic transducer Input electrical current:4-20ma, 0-10v Output pressure:20-100kpa Et-500 is electropneumatic transducer equipment, it can decrease supply pressure to produce output pressre which is effectively proportional to input electric signal. Supply pressure range:125kpaí½1000kpa.With bulk augmenter supply big flow (20.4 m3/h). Features: Flow rate: 7.6m3/h when supply pressure is 175kpa 20.0m3/h when supply pressure is 700kpa Min/max. Supply pressure: Minimum-3psig(21kpa) above maximum output Maximum-100psig(700kpa) Sensitivity:
Brass fasteners, brass current terminals, brass turned components, brass nuts and bolts, brass washers, brass sheet cutting parts, brass electrical accessories parts, brass electric energy meter parts, brass switchgear parts, brass automotive parts.FOB