Metal detector(hand held) Microprocessor controlled Auto calibration Advanced technology High sensitivity Membrane touch pad buttons Long battery life Push button ultra high recovery Replaceable & rechargeable battery Metal density vu-meter Audible & visual alarm Charger, belt holder, battery, wrist stripe included Optionals:vibration, earphone
1.Six overlapping detection region of the same height of human body. 2.With LED alarm light on columns displaying the accurate position of the targets. 3.Four corresponding infrared transmitters and receivers,no blind area. 4.Sensitivity of every area can be adjusted independently from 0-99,without the interference of scheduled metals. 5.Microprocessor digital control technology,strong anti interference ability. 6.The function of statistics:the number of passengers and alarms can be count. 7.It can be used independently or work together with the same mod(minimum spacing can be up to 40cm),to meet the requirements of the personnel large flow. 8.Password protection function:only the authorized person can operate it. 9.No harm to people, film and magnetic recording materials. 10.Installed conveniently:just put self-made four corner screws fixed door,plug in 220V power supply can be put into use
XX- line of portable X-ray units is designed to the principle of low cost and high reliability, which is characteristic in convenient to carry, easy to operate, and highly automated. X-ray tube and HT coil are all produced by DANDONG NDT which guarantees system consistency. Weight is further reduced with the use of SF6 insulation. Forced cooling fan guarantee the longevity of X-ray tube, which makes the product suitable for field and highly above work. K03/K05 control unit is microprocessor controlled with module of controlled silicon voltage adjustment and frequency conversion. The functions of fully automatic warm-up program, fault display, over voltage and mis-start protection, the stability and service life are much improved. 655 ¬200mm 15kg
Ch2o(formaldehyde) is a kind of gas which will cause damage to human body. It exists in many products like chemicals, laminate flooring, particle board, household products, glues, permanent press fabrics, paper product coatings, fiberboard, and plywood. It is also widely used as an industrial fungicide, germicide and disinfectant. Jw-100 ch2o detector adopt with high performance electrochemical sensors and sophistic- Ated circuit design, it has features like high stability, excellent anti interference ability. When the indoor ch2o concentration is over the standard, this detector can provide site alarm and remote alarm according to different degrees of ch2o (connect with alarm host).
High-risk security situations do not leave any margin for error thus requiring intricate security procedures designed to ensure safety and piece of mind. The tm-915 has been created specifically with this in mind. Tm-915 mainly used in detecting the close state of door and window, when the door or window opened as unknown reason and the detector will send out specific radio wave to alarm host to achieve remote alarm.
GVD301 vehicle loop detector Type: single channel Supply Voltage: 220V AC±10% Sensing range:20-1500µH Sensitivity: 0.02%-0.2% (7 degrees adjustable) Response time: 50ms Frequency: 2 degree adjustable, 15-120khz Output: 2 output relays (5A/AC230V) Relay 1: presence relay; relay 2: pulse/fault relay; CH1: presence relay; CH2: presence relay Working mode: Model: presence & pulse relay output; Model 2: presence & fault relay output Presence mode: Limited presence/permanent presence Pulse mode: pulse entry/ pulse exit; Pulse output time: pulse entry 200ms, pulse exit 200ms Presence output time: 30mins limited presence/permanent presence; Indicator: red: power, green: status indicator; Internal protection: loop isolation transformer, voltage-regulator tube, voltage dependent thermistance; Temperature:-40—80 centigrade
Specification Technology code for testing of building foundation piles JGJ106-2003 Technical specification of dynamic pile tests for highway engineering JTG/TF81-01-2004 Technology specification for inspection of concrete defects by ultrasonic method CECS 21:2000 Technical specification for detecting strength of concrete by ultrasonic-rebound combine method CECS 02:2005 Technical specification for geotechnical investigation method GB 50021-2001 Purpose Testing building foundation piles by crosshole ultrasonic wave method . Inspecting concrete defects by ultrasonic method, such as uncompacted place, cellular hole area Detecting concrete strength by ultrasonic-rebound combined method Detecting concrete crack depth by ultrasonic method Detecting the wall defects of the hole by one transmitter and two receivers Detecting the strength performance of geotechnical investigation, rock, concrete, etc Performance Fast, precise and automatic to judge the sound parameters. Real-time wave display to assure test efficiency Graphically display the test data, the user can view result directly. Can connect with the test hammer directly to detect the concrete strength. The function has been applied for national patent. Can receive signal with strong sensitivity more than 10m without defects in concrete. The host can supply energy to transducer without external power. Standard USB storage with big capacity Interior lithium battery can supply working power more than 6 hours. And more than 12hours combined with external lithium battery. Portable, small and light apparatus(1.75kg) Extending function to test concrete thickness by impact-echo method Professional and powerful analysis software on Windows system can output the data to Excel or word for advanced analysis.
Ty-20mj needle detector Product information Brand: inteke Ty-20mj needle detector Model: ty-20mj Description: - high delicacy and reliable performance. - high anti-jamming ability. - best quality assurance with best customer service. Application: suitable for textiles, knitgoods, crafts and costumes. Product info Battery: 6f22-9v Static current:
Application and Brief Intro LSST-01 Leak and Seal Strength Tester is suitable for the quantitative determination of sealing strength, heating sealing quality, burst pressure and leakage of flexible and aseptic packages. The Leak and Seal Strength Detector can also be used to determine the sealing performance of pilfer-free bottle caps and soft tubes. The compression strength, connection strength of cap and body, cap losing strength, seal strength and butting strength of tubes are the applications of LSST-01 Seal Strength Testing System. This Seal Strength Testing System conforms to standards of ISO 11607-1, ISO 11607-2, ASTM F1140, ASTM F2054, GB/T 10440, GB 18454, GB 19741, GB 17447, GB/T 17876, GB/T 10004, BB/T 0025, QB/T 1871, YBB 00252005, YBB 00162002 . Principle The three test modes of the positive pressure method, which LSST-01 Leak and Seal Strength Tester satisfies are as follows: A. Burst Test: LSST-01 Leak and Seal Strength Tester internally pressurizes the packages until the package fails. The test pressure is the maximum pressure detected before the package fails. B. Creep Test: Pressurize the package internally to a specific pressure and maintains this pressure for a specific time. The test measure is pass/fail. C. Creep to Failure: The package is creep-tested and held until the package fails. The pressure setting is higher than that of the creep test to ensure the package fails in some time. The measure is the time until failure.
specifications:sensor: electrochemical carbon monoxide sensor detecting range: 0-999ppm sensitivity: 5ppm error: ¡¨¤10% +15ppm the detecting precision is affected by detector itself and the temperature and humidity of the installation environment the best installation environment: 20 numerical readings and note: 3-digit lcd display of levels normal reading: 0 alarm readings: 30 - 999ppm battery capacity display: full, ok, low, dead sensor performance display: malfunction alarm modes: sound, beep, hummer light: red led flashing installation: wall and table power supply range: 110/220/230-240v ac backup battery: 1 x 9v alkaline battery working temperature: 0 - 60¡ãc relative humidity:
Overview: Digital ultrasonic flaw detector is the mainstream of nondestructive testing instrument equipment, with quick, easy, no damage positioning, evaluation and diagnosis of the internal workpiece.Our products adopt tft color lcd screen, with functions of simple operation, high precision detection , wide application range, fast response, high intelligence, flexible memory card size and other characteristics, is an ideal product of high cost performance products. Wooden case
Wasp-xm series pum-priming portable gas detector Outline Wasp-xm series pump-priming portable gas detector is a continuous monitoring of a variety of single gas detection equipment. This product is suitable for environmental monitoring, industrial production and other harmful gases working environment, which can effectively protect the health and safety of staff is not compromised. Main feature Smart probe design, calibration and Maintenance more convenient in the future; Fault, warning, operator error, alarm will be smart tips; Built-in cf calibration coefficients (voc measurements only valid); With audible alarm, visual alarm function, the status bar also displays alarm status; Full-color 3.5-inch tft screen, color lcd display and intuitive; Can be both digital and curve display of gas concentration in two ways; With usb communication port, you can speed 9600 bytes to communicate directly with the computer; With test record function, can store a month's measurement data and instrument or computer can view the data; With alarm recording function, you can record the last four times the alarm time and type; With calibration record; can record the last four times the size of the calibration time span; High-capacity lithium battery-powered, rechargeable, low battery automatic shutdown; Can be set high reported, underreporting, twa, stel, shutdown time, pump speed, etc.; Technical parameter Power supply: lithium battery (4.2v/3000mah) Operating current: normal current: ¡¡§1 150ma; alarm current: ¡¡§1 200ma 3¡¡¨¦operating environment: temperature: -40 ¡æ - 70 ¡æ Relative humidity: 15% - 95%, non-condensing 4¡¡¨¦storage environment: temperature: -20 ¡æ - 60 ¡æ
Kq500d intelligent gas detector is a kind of wall-mounted type detector that can be used continuously in operation environment to detect the concentration of combustion gas, oxygen, and toxic gas. The detector detects gas concentration in natural diffusion way. Kq500d intelligent gas detector transforms the gas density in the operating site into standard electric current signal(4-20ma). With led display, detector's sensor can be changed and reused as soon as it is connected to electricity. Main features: standard 4-20ma electric current output, compatible with existing alarm control unit or dsc (distributed control system). led site display that is suitable for factory (optional lcd display) L standard three buttons: so an individual can operate the detector in site. L automatic identify and display the sensor failures, and output the corresponded current signal at the same time. L the key operation needs to input password to prevent wrong operation. L simple calibration function; reducing measuring error L two levels' light alarm, relay output (connected with audible and visual alarm outside or start the exhaust system) Box
Kq500 fixed gas detector is a kind of wall-mounted type detector that can be used continuously in operation environment to detect the concentration of combustion gas, oxygen, and toxic gas. The detector detects gas concentration in natural diffusion way. Kq500 intelligent gas detector transforms the gas density in the operating site into standard electric current signal(4-20ma). Main features: L it can detect more kinds of gas. High precision L fixed explosion-proof shell; it¡¯s safe and reliable L standard 4-20ma electric current output, compatible with existing alarm control unit or dsc (distributed control system). L imported sensor, high sensitivity, rapid response, stable and reliable Operation is simple; easy installation and maintenance Box
Pg 610 series portable gas detecter: it can detect one kind of gas. It is intrinsically safe instrument that can continuously detect the concentration of combustible gas and toxic gas. It is portable detector. Main features: Big oled display, highlighted, high-definition automatically save the detecting data for 5000 articles data progress bar display mode, can learn about the state of concentration low power consumption , save energy, save electricity displays in english words, is easy to understand and operate Real-time clock display function the key operation needs to input password to prevent wrong operation. Automatic calibration function, reduce the measuring error. Recover key data, avoid the loss of data Battery power real-time display, under-voltage hint, low pressure automatic shutdown standard mini-usb charging interface; charger is compatible with computer and cell phone's charging protection function; when battery is full, charger will shut down automatically. Computer connection function; to realize data download, parameter setting (optional) Alarm type: audible and visual alarm, vibrating alarm stel and twa alarm function for toxic gases power on self-test function adjust high and low alarm level replaceable modularized sensor.
BX626 portable multi-gas detection alarm is a flexible configuration for single gas or a variety of gas detection alar. It can be equipment with oxygen sensors, sensors of combustible gases and toxic gas sensors or any four gas sensors or single sensor. BX626 has a very large clear LCD, backlight, vibration alarm sound and light, which makes sure the dangerous gases detection even in a harsh working environment and prompts staff in time to prevent accidents. Features: 1. Compact, lightweight, sturdy 2. Sound, light, vibration alarm 3. Large screen digital, character display, instantaneous value, peak value, average value display 4. Self-test of the battery, sensor, alarm function when necessary or boot 5. Safety tips: Regular Flash, voice prompts 6. Superior audio sound alarm 7. Low maintenance costs 8. Detect one, two, three or four kinds of gases(4 in 1 gas detector with 4 gas sensors) Main functions and features Measuring gas O2, CO,H2S,flammable gas Measuring range O2:0-25%VOL,CO:0-2000ppm,H2S:0-200ppm, combustible gas:0-100%LEL Sensor type Electrochemical, catalytic combustion sensor Alarm mode Sound alarm more than 90dB (10cm); Light alarm red LED; Vibration alarm Data storage save 64 sets of data Backlight bright yellow backlight Work mode Continuous working Combustible gas can work continuously for 12 hours Response time less than 40s Weight 200g Temperature range -20¡ãC ~ 50¡ãC Humidity range 0 ~ 95%(Non-condensing) packed in cartons weight 200g
AD-C water detector Whole weight:2.5kg, Size: 31cmx23cmx10.8cm
Passive infrared detector Operating voltage:dc 9-16vstatic current:30ma operating temperature:-10 to +50 installation method:ceiling mountedinstallation height:approx 2.5-6mdirection identification:enter from outside: alarmexit from inside: without alarmdetection angle:15 detection range:diameter 6m / height:3.6malarm output:normal closeanti tamper switch:normal close size:102.5 *83*27mm
Wireless passive infrared detector Technical specificationoperating voltage:9v~16vdcstatic current: 50 a operating temperature:-10 to +50 installation:wall mountedtransmitting distance: 80m without obstructiontransmitting method:askdetection angle:110íp detection range:12*25malarm frequency:433.92m; 315manti tamper switch: n.C. In contacting point; N.O. Shows alarm. (green led on)size:104*60*32mm
Standard features of bw products: • continuous lcd shows real-time gas concentrations • compact and lightweight design makes it comfortable to wear • water-resistant • simple automatic calibration procedure; compatible with Bw microdock ii automatic test and calibration station • full function self-test of sensor, battery status, circuit integrity And audible/visual alarms on start up • bright wide-angled visual alarm bars • built-in concussion-proof boot Gas measuring range resolution H2s 0-100 ppm 1 ppm Co 0-500 ppm 1 ppm O2 0-30.0% 0.1% Combustible 0-100% lel 1 0% Gases 0.5%v/v 0.1%.