Alstom Gbcdd21pf9058bch Self-powered Dir. Inverse Time O/c or E/ Technical Specification Relay Model Cdd21pf9058bch Cdd21 Case Size 1-1/2d Vert. 10t Application E/f C.t. Secondary 1 Amp Ct. E/f Setting 0.2 - 0.8 Amps Burden / D.m.t 3va / 3 Secs Aux.voltage 100 - 250 V Dc Contacts 2 N/o S/r Flag Yes Frequency 50 Hz Mounting Flush Mta Phase-char Angle 45 Degrees V.t/p.t Secondary 63 / 190 V Ac Tap Std Name Plate-1 Rfg9126-039 Outline Drawing Mfj013 Wiring Diagram Mpdz801-10-1
Alstom Gbcdd21pf9353ach Dir.idmt O/c Relay 1va 1.3 Secs (Non-std Technical Specification Cdd21 Relay Model Cdd21pf9353ach Case Size 1-1/2d Vert. 10t Application O/c C.t. Secondary 1 Amp Ct. Current Setting 0.5 - 2 Amps Burden 1 Va D.m.t 1.3 Sec Taps Std Aux.multi Voltage 100 - 125 /220 250 V Dc Contacts (S/r or H/r) 2 N/o S/r Flag Yes Mounting Flush Mta Phase-char Angle 30 Degrees V.t/p.t Secondary 110 V Ac Frequency 50 Hz Name Plate-1 Rfg9126-017 Outline Drawing Mfj013 Wiring Diagram Mpdz801-10-1
ALSTOM GBCDD21PFB2AA5C DIRECTIONAL IDMT O/C RELAY,3VA 3SEC DMT Technical specification Relay model no CDD21PFB2AA5C Relay type CDD 21 Case size 1.5D S.E 10 T Application O/C Current setting 2.5 to 10 amps Contacts 1 N/O S/R Output contacts 1 N/O S/R Flag Mech Flag Taps Std C.T.Secondary 5 Amp Burden/Operating time 3VA / 3 Secs Nominal Voltage 100/120 V AC Frequency 50 Hz Name plate RFG9126 021 M.T.A.I Lead/Lag 45 Deg Lead Note: Use ZB9016224 (RV1) In Place of RZB9016059 Outline drawing RFJ0070602 Wiring diagram PDZ 001-203
ALSTOM GBCDG11AF001SACH SELF-POWERED INVERSE TIME O/C OR E/F REL Technical Specifications Model No CDG11AF001SACH CDG11 APPLICATION - O/C BURDEN / D.M.T - 3VA / 3 SECS. C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O S/R E/F OR U/V SETTING - NOT APPLICABLE FLAG - YES MOUNTING - FLUSH O/C OR O/V SETTING - 2.5-10 Amps. Name Plate RFG9126674 Outline Diagram MFJ012 Wiring Diagram MADZ802.63-1
ALSTOM GBCDG11AF001SCCH SELF-POWERED INVERSE TIME O/C OR E/F REL Technical Specifications Model No : CDG11AF001SC(M) CDG11 APPLICATION - O/C BURDEN / D.M.T - 3VA / 3 SECS. C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R E/F OR U/V SETTING - NOT APPLICABLE FLAG - YES MOUNTING - FLUSH O/C OR O/V SETTING - 2.5-10 Amps. Name Plate RFG9126 774 Outline Diagram MFJ012 Wiring Diagram MADZ802.64-1
ALSTOM GBCDG11AF002SACH SELF-POWERED INVERSE TIME O/C OR E/F REL Technical Specifications Model No CDG11AF002SACH CDG11 APPLICATION - O/C BURDEN/D.M.T - 3VA/3 SECS. C.T. SECONDARY - 1 AMP CT. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O S/R E/F OR U/V SETTING - NOT APPLICABLE FLAG - YES MOUNTING - FLUSH O/C OR O/V SETTING - 0.5-2 Amps. Name Plate RFG9126671 Outline Diagram MFJ012 Wiring Diagram MADZ802-63-1
GBCDG11AF002SCCH SELF-POWERED INVERSE TIME O/C OR E/F REL Technical Specifications Model No : CDG11AF002SC(M) CDG11 APPLICATION - O/C BURDEN / D.M.T - 3VA / 3 SEC. C.T. SECONDARY - 1 AMP CT. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R E/F OR U/V SETTING - NOT APPLICABLE FLAG - YES MOUNTING - FLUSH O/C OR O/V SETTING - 0.5-2 Amps. Name Plate RFG9126 771 Outline Diagram MFJ012 Wiring Diagram MADZ802.64-1
ALSTOM GBCDG11AF003SACH SELF-POWERED INVERSE TIME O/C OR E/F REL Technical Specifications Model No CDG11AF003SACH CDG11 APPLICATION - E/F BURDEN / D.M.T - 3VA / 3 SECS. C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O S/R E/F OR U/V SETTING - 1-4 Amps. FLAG - YES MOUNTING - FLUSH O/C OR O/V SETTING - NOT APPLICABLE Name Plate RFG9126796 Outline Diagram MFJ012 Wiring Diagram MADZ802.63-1
ALSTOM GBCDG11AF003SCCH SELF-POWERED INVERSE TIME O/C OR E/F REL Technical Specifications Model No : CDG11AF003SC(M) CDG11 APPLICATION - E/F BURDEN /D.M.T - 3VA / 3 SECS. C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R E/F OR U/V SETTING - 1-4 Amps. FLAG - YES MOUNTING - FLUSH O/C OR O/V SETTING - NOT APPLICABLE Name Plate RFG9126 796 Outline Diagram MFJ012 Wiring Diagram MADZ802.64-1
ALSTOM GBCDG11AF004SACH SELF-POWERED INVERSE TIME O/C OR E/F REL Technical Specifications Model No CDG11AF004SACH CDG11 APPLICATION - E/F BURDEN - 3VA / 3 SECS. C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O S/R E/F OR U/V SETTING - 0.5 - 2 Amps. FLAG - YES MOUNTING - FLUSH O/C OR O/V SETTING - NOT APPLICABLE Name Plate RFG9126-795 Outline Diagram MFJ012 Wiring Diagram MADZ802.63-1
ALSTOM GBCDG11AF004SCCH SELF-POWERED INVERSE TIME O/C OR E/F REL Technical Specifications Model No : CDG11AF004SC(M) CDG11 APPLICATION - E/F BURDEN / D.M.T - 3VA / 3 SECS. C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R E/F OR U/V SETTING - 0.5 - 2 Amps. FLAG - YES MOUNTING - FLUSH O/C OR O/V SETTING - NOT APPLICABLE Name Plate RFG9126 795 Outline Diagram MFJ012 Wiring Diagram MADZ802.64-1
ALSTOM GBCDG11AF005SACH SELF-POWERED INVERSE TIME O/C OR E/F REL Technical Specifications Model No : CDG11AF005SA(M) CDG11 APPLICATION - E/F BURDEN / D.M.T - 3VA / 3 SECS. C.T. SECONDARY - 1 AMP CT. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O S/R E/F OR U/V SETTING - 0.2 - 0.8 Amps. FLAG - YES MOUNTING - FLUSH O/C OR O/V SETTING - NOT APPLICABLE Name Plate RFG9126793 Outline Diagram MFJ012 Wiring Diagram MADZ802.63-1
ALSTOM GBCDG11AF005SCCH SELF-POWERED INVERSE TIME O/C OR E/F REL Technical Specifications Model No : CDG11AF005SC(M) CDG11 APPLICATION - E/F BURDEN / D.M.T - 3VA / 3 SECS. C.T. SECONDARY - 1 AMP CT. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R E/F OR U/V SETTING - 0.2 - 0.8 Amps. FLAG - YES MOUNTING - FLUSH O/C OR O/V SETTING - NOT APPLICABLE Name Plate RFG9126 793 Outline Diagram MFJ012 Wiring Diagram MADZ802.64-1
GBCDG11AF006SACH SELF-POWERED INVERSE TIME O/C OR E/F REL Technical Specifications Model No CDG11AF006SACH CDG11 APPLICATION - E/F BURDEN / D.M.T - 3VA / 3 SECS. C.T. SECONDARY - 1 AMP CT. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O S/R E/F OR U/V SETTING - 0.1 - 0.4 Amps. FLAG - YES MOUNTING - FLUSH O/C OR O/V SETTING - NOT APPLICABLE Name Plate RFG9126 Outline Diagram MFJ012 Wiring Diagram MADZ802.63-1
ALSTOM GBCDG11AF006SCCH SELF-POWERED INVERSE TIME O/C OR E/F REL Technical Specifications Model No : CDG11AF006SC(M) CDG11 APPLICATION - E/F BURDEN / D.M.T - 3VA / 3 SECS. C.T. SECONDARY - 1 AMP CT. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R E/F OR U/V SETTING - 0.1-0.4 Amps. FLAG - YES MOUNTING - FLUSH O/C OR O/V SETTING - NOT APPLICABLE Name Plate RFG9126 792 Outline Diagram MFJ012 Wiring Diagram MADZ802.64-1
ALSTOM GBCDG11AF008SACH SELF-POWERED INVERSE TIME O/C OR E/F REL Technical Specifications Relay Model No CDG11AF008SACH Relay type CDG 11 Special Case size 1D V 10T Application O/C Current setting 0.5 to 2 amps Contacts 3 N/O S/R Output contacts 2 N/O S/R Taps Std C.T.Secondary 1 amps Burden 3 VA Operating time 3 secs Flag Yes Mounting Flush Name Plate RFG9126 771 Outline Diagram MFJ 012 Wiring Diagram MADZ 802.66-1
ALSTOM GBCDG11AF009SACH SELF-POWERED INVERSE TIME O/C OR E/F REL Technical Specifications Relay Model No CDG11AF009SACH Relay type CDG 11 Special Case size 1D V 10T Application E/F Current setting 0.2 to 0.8 amps Contacts 3 N/O S/R Output contacts 2 N/O S/R Taps Std C.T.Secondary 1 amps Burden 3 VA Operating time 3 secs Flag Yes Mounting Flush Name Plate RFG9126 793 Outline Diagram MFJ 012 Wiring Diagram MADZ 802.66-1
GBCDG11AF011SACH SELF-POWERED INVERSE TIME O/C OR E/F REL Technical Specifications Model No : CDG11AF011SA(M) CDG11 APPLICATION - O/C BURDEN / D.M.T - 3VA / 1.3 SECS C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O S/R E/F OR U/V SETTING - NOT APPLICABLE FLAG - YES MOUNTING - FLUSH O/C OR O/V SETTING - 2.5 - 10 Amps. Name Plate RFG9125674 Outline Diagram MFJ012 Wiring Diagram MADZ802.63-1
GBCDG11AF011SCCH SELF-POWERED INVERSE TIME O/C OR E/F REL Technical Specifications Model No : CDG11AF011SC(M) CDG11 APPLICATION - O/C BURDEN / D.M.T - 3VA / 1.3 SECS. C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R E/F OR U/V SETTING - NOT APPLICABLE FLAG - YES MOUNTING - FLUSH O/C OR O/V SETTING - 2.5 - 10 Amps. Name Plate RFG9125 774 Outline Diagram MFJ012 Wiring Diagram MADZ802.64-1
ALSTOM GBCDG11AF012SACH SELF-POWERED INVERSE TIME O/C OR E/F REL Technical Specifications Model No : CDG11AF012SA(M) CDG11 APPLICATION - O/C BURDEN / D.M.T - 3VA / 1.3 SECS. C.T. SECONDARY - 1 AMP CT. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O S/R E/F OR U/V SETTING - NOT APPLICABLE FLAG - YES MOUNTING - FLUSH O/C OR O/V SETTING - 0.5 - 2 Amps. Name Plate RFG9125671 Outline Diagram MFJ012 Wiring Diagram MADZ802.63-1