Energizer E91 AA Model No.: E91 Size: AA Nominal Voltage: 1.5V Nominal IR: 150 to 300millionhms Operating Temp: -18â?? to 55â?? Typical Weight: 23.0 gram Shelf Life: 10 years Energizer E92 AAA Model No.: E92 Size: AAA Nominal Voltage: 1.5V Nominal IR: 150 to 300millionhms Operating Temp: -18â?? to 55â?? Typical Weight: 11.5 gram Shelf Life: 10 years
SANDI SERIES charging module is for electric vehicle charging station. With single-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic. Functional details 1. Hot plug Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system. 2. Advanced current sharing technology Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than �±0.5A. 3. Control of input limited power Refer to Fig. 1-10 for the relation between the output power and input voltage of the charging module. When the input voltage is within 360 Vac ~ 450 Vac (return difference is less than 5V), the module can output the maximum power of 20 KW; when the input voltage is within 260 Vac ~ 320 Vac, the module can still work normally under limited power mode. 4. Control of output constant power When there is a rated input voltage, the output power of the module is 20 KW. Refer to Fig. 11 for the relation between the output voltage and the output current of the module. The SD75050 module uses two operating modes with output voltage ranges of 50 to 750V. The module only selects the operating mode based on the value of the received demand voltage, and does not select the operating mode based on the actual output voltage. 5. Temperature limited power 6. Regulation of output current limiting point 8. Regulation of output voltage The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 750Vdc and minimum regulation step of 0.1 Vdc. 9. Fan control The built-in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module. 10. Protection of input overvoltage/ voltage shortage 11. Output overvoltage protection The overvoltage protection point is 260Vdc ~770Vdc (�±10 Vdc). Default is 778Vdc.The module can be started after manual intervention upon overvoltage protection. 12. Over-temperature protection The environmental over-temperature protection point is 80�°C. When the DC panel has a temperature over 100�°C, the module will stop working; when the DC panel has a temperature below 90�°C, the module will automatically work again. 13. Protection of internal bus fault When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on. 14. Short circuit protection In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the "module fault".
Battery Tester Checker Universal Battery Tester Monitor (BT01) Quick Sense(BT01): Battery Tester Checker Universal Battery Tester Monitor for AA AAA C D 9V 1.5V Button Cell Batteries Easily check if the batteries are good or bad. It can test different types of batteries, even rechargeable ones. Fit For: AA/AAA/C/D/9V/1.5V Button Cell Battery (Batteries not included) This will keep you from wasting good batteries by throwing out good ones. Small and practical - Simple but effective little battery tester checker(BT-168), compact size and lightweight, easy to carry.
Digital Battery Tester Household Battery Checker Tester for Small Batteries Button Cell BT-168D Digital Battery Tester for AAA AA C D 9V 1.5V, Household Battery Checker Tester for Small Batteries Button Cell (Model: BT-168D) Get accurate readings on AA, AAA, C, D, and 1.5V 9V batteries Easy-to-read, digit indicates power level Check power level of 9V and 1.5V battery Quickly test the capacity of your battery Lightweight and compact design measures 11Ã?? 6Ã?? 2.5 cm Never again get caught with a dead household battery. This handy digital battery tester makes it easy for you to get the most out of your batteries and lets you know when it is time to get a new one.
Small size and lightweight, convenient to carry, Easy and safe to use, no sparking 6 LED displays, clearly present the alternator and battery state. Two testing clips for safe and easy operation. Suitable for 12V lead-acid batteries, hardtop batteries, discharge batteries, and maintenance-free batteries heavy duty insulated clamps. Multiple functions- Alternator state check, battery state check, Battery overload display With a good chip inside, not easy to get hot on the surface, suitable for cars, motorcycles, etc.
Small size and lightweight, convenient to carry, Easy and safe to use, no sparking 6 LED displays, clearly present the alternator and battery state. Two testing clips for safe and easy operation. Suitable for 12V lead-acid batteries, hardtop batteries, discharge batteries, and maintenance-free batteries heavy duty insulated clamps. Multiple functions- Alternator state check, battery state check, Battery overload display With a good chip inside, not easy to get hot on the surface, suitable for cars, motorcycles, etc.
1. According to the international standard design, each channel of the system has an independent constant-current source and constant-voltage source. 2. The internal electrical power supply uses the high efficiency switching power supply, the energy conservation effect is remarkable, each power tube has the independent protection circuit, guarantees the equipment works with safety and reliability. 3. Measure adopts four wire method, decrease contact error, increase measure precision. 4. Each channel is independent with high efficient cooling system, equipment can work 24 hours with full load. 5. Hardware adopts double loop control, can change from constant current to constant voltage without pinnacle, protect battery. 3u, 482.6*378*130(mm) 15kg.
According to the international standard design, each channel of the system has an independent constant-current source and constant-voltage source The internal electrical power supply uses the high efficiency switching power supply, the energy conservation effect isremarkable, each power tube has the independent protection circuit, guarantees the Equipment works with safety and reliability. Measure adopts four wire method, decrease contact error, increase measure precision. 1450 * 380 * 1780(mm) 350KGS.
Basic Parameters Dimensions: 201 x 99 x 35 mm Weight: 333g Adapter Input: AC 100 ~ 240 V Output: DC 24V 2.65A Display mode Segment LCD with white backlight + LED in red and green Function Introduction Charge Active, pre-charge, constant current and constant voltages are the stages of charging mode. The initial charging mode depends on the battery voltage, so active and pre-charge don't happen to every batteries. For charging mode and current, please refer to the paragraphs of charging mode and charging current on page 2 & 3. Tester will stop charging if one of the conditions below was met. 1) Remaining capacity 99% & current intensity = 0 2) Remaining capacity = full charge capacity 3) Current intensity reduce to end charge current when constant voltage charge 4) Remaining capacity reach up the set value Discharge Constant current discharge for double loads Inner load: 0 ~ 1000mA, adjustable continuously via Battery Manager External load: 0mA, 500mA, 1000mA, 1500mA, 2000mA, five gears with dip switches offered Tester will stop discharging if one of the conditions below is met. 1) Remaining capacity set value 2) Voltage set value 3) Current intensity reduce to zero Remarks: Many batteries can not measure exact current intensity, which cause an else current value appears after you set a value. However, the actual discharging current is the same with your set value. Test Testing time is 12 seconds and the purpose is to check both the charging and discharging performances. After finishing test, LED flickers with green color and LCD reports the test result. Normal: Test OK Shown on LCD Abnormal: Test NG Shown on LCD Possible causes and solutions for the abnormal: 1) Cause: battery voltage is too low to discharge Solution: try to charge the battery to raise voltage 2) Cause: remaining capacity is too full to charge any more Solution: try to discharge the battery to reduce the remaining capacity 3) Bad contact of battery connecting wires 4) Damaged battery 5) Tester trouble Capacity Correction The battery capacity value in the battery management chip will different from the actual capacity after a battery goes through many recycling cycles. It will affect the use of the battery when the difference reaches a certain degree. Capacity correction is to deep discharge a battery and then fully charge, which will correct the capacity value in the battery management chip. Remarks: Discharging current can be set via Battery Manager. Deep discharge will cause a battery losing communication with tester, so battery dropping phenomenon may happen in the discharging process if the end capacity and voltage are set too low. In such a case, active charge will make the battery work again. 50% Capacity CD50%: charge firstly, and then discharge to 50% capacity DC50%: discharge firstly, and then charge to 50% capacity Online Functions Tester can be connected with master machine via a USB port. Users can monitor, control and set parameters via Battery Manager software in the master machine. Monitoring Battery information can be monitored via three windows. 1. Home screen Battery bar and brief information can be read on home screen. 2. Battery detail information window Show smart battery data in real time and the data can be saved and printed in image format. 3. Battery graph window Voltage, current and capacity are traced in curves. Control Battery Manager can control slave machine completely. Right-click menu on the battery bar includes the related commands. Attention All the functions of charge, discharge, capacity correction and 50% capacity are comply with the charging discharging conditions, which are showed on function introduction paragraph in page 4 & 5, so parameters should be set reasonably. Especially, deep discharge will cause a battery losing communication with tester. Others 1. Active cooling 2. Active batteries of zero voltage When a battery is deep discharged, the discharge protection circuit will start up and the voltage in the battery connector will become zero voltage. In this case, an appropriate voltage should be supplied to active the battery. 3. Battery identification Battery information can be read from battery management chip after establishing communication. 4. Intelligent protection Against over-current, over-voltage, over-charge, over-heat and short circuit. 5. Fan Discharging mode: fan startup Other modes: fan startup when temperature above 48 Fan stop working when temperature below 40 6. Trouble alarm LED flickers in red color and current command stops when one of the conditions below happen. 1). There is not current for around 50 seconds when charge. 2). There is not current for around 25 seconds when discharge. 3). Charging time is above 8.8 hours. 4). Discharging time is above 9.9 hours. 5). Suitable for almost all laptop batteries, above 95% Structure Accessories 1).1 * adapter 2). 1 * USB cord 3). 1 * CD 4). 13 * connectors 5). 10 * cables 6). 10 * jumpers 7). 1 * loader Standard Export Carton
Product Introduction: Name:Digital Battery Teste Item No.:Â M03006 Country of Origin: China The Digital Battery Tester is a type of multimeter, can Analyze your car battery condition with this battery analyzer.Digitally analyze the condition of your automotive batteryDigitally analyze the condition of your automotive battery with this easy-to-use battery analyzer. This unit checks voltage, cold cranking amps (CCA), resistance and overall battery condition and displays information on a large backlit LCD screen. Checks voltage, cold cranking amps (CCA), resistance and overall battery condition Continuous testing will not damage battery Uses car battery for power, no extra internal batteries needed Large backlit LCD screen Includes removable rubberized protective sleeve Easy-to-carry and durable design with this easy-to-use battery analyzer. This unit checks voltage, cold cranking amps (CCA), resistance and overall battery condition and displays information on a large backlit LCD screen. Checks voltage, cold cranking amps (CCA), resistance and overall battery condition Continuous testing will not damage battery Uses car battery for power, no extra internal batteries needed Large backlit LCD screen Includes removable rubberized protective sleeve Easy-to-carry and durable design More information can view Auto Tools Depot.
5V50mA Button Cell Battery Tester For Charging and Discharging Test Coin Cell Performance
1.battery pack monomer consistency evaluation test. 2.Internal resistance test of the entire battery pack. 3.Load test of battery pack. 4.Battery pack high current protection test. 5.Battery authenticity short-circuit protection test. 6.Battery pack continuous charging test. 7.Battery pack high current charging protection test.
Mobile phone Battery Performance / Lightning Cable / Headphone Cable Diagnostic Tester box, with 4pcs different Test Board, Universal Mobile phone Battery performance Diagnostic Tester for Phone W28 Pro Mobile phone Battery Performance Tester Lightning Cable Detector Function: Nowadays, many shoddy batteries are so dazzling in the market that we waste the most of our money unknowingly; Some battery protection boards are original, but the cells are set up afterwards; Some protection boards and batteries both are set up afterwards, some are the original but have been cycled hundreds of times, and it is sold again after the parameters are cleared; In short, Every situation could appear; with the battery test box emergence, these problems would go away! Cleaing and identifing only need one second, let the sham battery, high imitation battery nowhere to hide. Writing the cycle times at random: Double-click the button on the right to write randomly the cycles times of battery (1-9). The times of battery cycles is cleared: Click the right button, then, the times of battery cycles is cleared. Battery charging activation: The box needs to be connected to the charger, plug in the battery, short press the left button, it will enter the charging state, at this time, the battery current will display the charging milliamps, the default is maximum 500ma; This function is for batteries which can not charge and need to be charged. Special Reminder: Regarding the problems that occurred during the upgrade process, if upgrade is successful but the instrument does not restart automatically, you need manually turn the power off and turn it on again. If upgrade is unexpectedly interrupted or failed, you can turn off the power, then press the right button on the instrument and turn on the instrument again. Computer will prompt the instrument has been connected, upgrade mode, and now, you can upgrade again. Precautions: The instrument itself needs to be fully charged and used so that get an accurate test result. If the power supply is insufficient, please charge it in time. The upper right corner on the screen is the battery power of the instrument. If the screen dim out or flickering during the test, it is considered as low power. Please charge and use it
After years of research and development our company has successfully developed a series Battery discharge tester with high intelligence and precision with its proprietary technology. Discharge meter can be in offline mode battery as discharge load Through continuously regulating discharge current constant discharge current at the set value can be realized. When discharging the instrument will automatically stop discharging when the battery terminal voltage or monomer voltage falls to the set lower limit or the set discharge time or the set discharge capacity and record all valuable and continuous real-time process data. Battery discharge meter system the voltage monitoring information of single battery is simple safe and accurate with wireless relay access. Battery discharge meter has a very friendly man-machine interface which can not only complete all kinds of settings and data query under the prompt of menu but also save the process data of discharge in the memory of the equipment transfer to the U disk through the data interface and analyze the data through the special software of the upper computer to generate the required curve and report.
Send InquiryCHAT NOW Product Details Product description When the voltage of the battery pack or the voltage of a single battery is less than the set voltage lower limit, or the set discharge duration or set discharge capacity has been reached during discharge, the tester will automatically stop discharging and record the discharge Real-time data of all valuable and continuous processes in the process. Battery charge and discharge tester Technical index Applicable battery Lead-acid battery Model DC220V Discharge current 0-100A recharging current 0-30A Operating mode Used independently or with a constant-current module Control accuracy Discharge current: â?¤�±1%; battery packâ??s terminal voltage: â?¤ �±0.1%; single battery voltage: â?¤�±0.05% Communication with the host PC RS485 interface Data storage capacity 2Gbit FLASH
ModeL24/1548/1548/30110/05110/10220/05220/10 Cell voltage measurement type2V/6V/12V Cell voltage measurement range2V:04V;6V:08V;12V:015V Cell voltage resolution2V/6V:0.001V;12V:0.01V Voltage measurement range of battery string030V060V060V0135V0270V0270V String voltage resolution0.01V0.1V Voltage testing accuracy0.5% Discharge current working range2A150A2A150A2A300A250A2-100A250A2100A Constant current discharge voltage range21V30V42V60V42V60V90140V90140V180270V180270V Discharge PowerMax. 4.5kwMax. 9kwMax. 18kwMax. 7kwMax. 13.5kwMax. 13.5kwMax. 27kw Current testing accuracy1% Battery capacity check range20Ah1500 Ah20Ah1500 Ah20Ah3000 Ah20500Ah201000Ah20500Ah201000Ah Current testing accuracy1% Capacity check testing range extensionOne external load added, the testing capacity range doubled Cell data collection methodwire,wireless(optional) Monitoring current range0300 A Working voltageAC220 Cooling modeRefrigeration by blast Working environment;20%80%RH Storage condition-20;C storage and transport Communication modeRS232 communication Data storage modeSD card Display mode4.7 inch TFT Instrument dimensions(mm)400*243*301430*248*381400*243*301 Weight(Kg)141714 Carry methodPortable type Dimensions : 40*24*30cm Weight : 13kg Packing: as your option
MEGA-IDEA Battery Tester Programmer for Phone, The battery connection buckle can be copied to the corresponding connector of CLONE MAN, and the original battery data is written. The cycle is cleared and the efficiency is corrected. Mega-iDEA Phone Battery Tester Programmer for Phone Features 1. Support Phone Battery Data Write and Read 2. Support checking battery is Original or non-Original 3.Support battery Cycle Clearing Tool
* Wide voltage range battery discharger: 12V to 280V * 5.7 inch LCD touch screen for easy operation and showing various parameters real time * Selectable discharge mode: constant current/power / resistance * 4 adjustable stop points and multiple alarm designs to control the discharge process intelligently * Support RS232 real time monitoring by PC or USB download data after discharge * PC software for capacity evaluation and report generation * Optional wireless modules for 1.2V/2V/6V/12V cells voltage real-time measuring. Overview: Although battery resistance testing methods are improving and very popular, battery discharge test still is the most accurate and reliable method for actual capacity evaluation of battery groups. Because only constant current discharge can perfectly simulate the working status under loading for batteries, power supply departments in many companies and utilities keep the periodic discharge testing in their maintenance management. Because the DC power systems in various industrial utilities are using different voltage level battery groups (24V, 48V, 110V, 120V, 220V, 240V etc.), and most of professional users hope to find an unattended and automatic instrument to simplify discharge process, the battery discharge tester with intelligent designs and super voltage variability for almost all battery types would be preferable. Features: Wide Range 840CT can support 10-300V battery groups, the application of 840CT includes: Battery Nominal Voltage: Max Discharge Current 240 V / 220 V: 60 A 120 V / 110 V: 120 A 96 V: 120 A 48 V: 120 A 24 V: 120 A 12 V: 60 A Multiple Adjustable Stop Points 840CT offers 4 adjustable points for test stop points to avoid excessive discharge: Stop Point: Setting Range Group Low Voltage: 0-250.0 V Discharge Time: 0-99 Hour 99 Min Discharge Capacity: 0-9999 AH Cell Low Voltage: 0-15.00 V. 840CT also offer selectable quantity of cells which voltages below the stop point, this design could help you to locate more lag batteries in once constant discharging. Selectable Discharge Modes 840CT provides 3 discharge modes for different test requirement: Discharge Mode: Range Constant Current: 0-120 A Constant Power: 0-14 Kw Constant resistance: 0.16 5.7 inch Touch LCD Display Super big size touch LCD can display all real time data and graphs and support the click operations directly, humanized input method and menu designs simplified operating process. Presetting Function: The presetting function for discharge parameters provide 8 locations for setting up all discharge parameters in advance, this design can skip the setting procedures for the same discharging, simplified the operation and speed up the test. Internal Memory: * 840CT can save several independent discharge records automatically without Laptop monitoring, non-volatile internal memory guarantee the data security even in unexpected shutdown. * The menu interface provides some management operations like reviewing, deleting, downloading to PC by USB disk or RS232. Optional wireless cells voltage monitoring * Wireless modules for cells voltage measuring are available for 1.2V/2V/6V/12V batteries voltage monitoring during discharge test. * Each wireless module can monitor 4 batteries simultaneously. Comparing with the traditional cable voltage measuring method that each module only can monitor 1 battery, the new wiring operation is much easier. * With proper number wireless modules, main tester can real time scan and display the voltage data of each battery during the discharging, and display the histogram of all batteries to follow the battery voltage tracks in whole discharging process. * Intelligent judge program: 840CT can identify the situations that the battery voltages reach the threshold value or the signal missing by manual mistake. Avoiding manual interruption in the discharging, this revolutionary program makes the test stable and smooth. * 840CT also supports cable modules for special requirements. Multiple Protections & Alarms: Malfunctions: LCD prompt: beep warning Input over-voltage Reverse polarity Overload Overheat 840CT provides ample protective measures for various abnormal situations during discharge. Automatic termination, LCD prompt and beep warning would assist users to make proper treatments. Extendable & Compatible: Connecting with clamp current, 840CT cooperate other types in -CT series or any other load units, and clamp current can count external current in. PC ANALYSIS SOFTWARE: * Support data downloading and analyzing through real time communication or USB memory devices * The software interface includes: battery voltages curve and bar chart, battery resistances bar chart, group voltage curve, current curve, capacities histogram, data form and so on. * Powerful capacity estimating function, the software can predict the capacity of each battery in the tested group. * The software shows the data by various ways like bar charts, curve, and form. And users can magnify or minify any windows to read more details. * Automatically create EXCEL data report, it¡¯s so convenient to send or download the data. SPECIFICATIONS: Discharge Ranges Voltage range: current range 10-15V: 0-60A 15V-60V: 0-120A 86-150V: 0-120A 190-280V: 0-60A Current measurement: Internal current range: 0-120A Accuracy &resolution: 0.5%, 0.1 A External current range: 0-600A(optional current clamp) Accuracy &resolution: 1%, 0.1 A Voltage measurement Group voltage range: 0-300 V Accuracy &resolution: 0.5%, 0.1 V Cell voltage range: 0-15V Accuracy &resolution: 0.5%, 0.01 V Power Supply Power supply voltage: 220 V AC (-20% to +30%) Frequency: 50/60 Hz Power consumption:: 350W(max) Communication & Storage Communicate port: USB/RS232 Internal memory: 8Mbit Flash CE Certificate: LVD standards : 2006/95/EC:EN 61010-1:200 EMC standards: 2004/108/EC Annex II: EN 61000-6-1:2007 EN 61000-6-3:2007 EN 61000-3-2:2006+A2:2009 EN 61000-3-3:2008 Environment: Operation temperature: -5 to 50o C Storage temperature: -40 to 70o C Humidity: 5% - 95% RH Altitude: below 4000 m Working noise: