Vsm-12 series vacuum circuit breaker
Sell dz47-63 mini circuit breaker Dz47-63 Standard:iec60898 Construction and feature Protection against the overload and short circuit High short circuit capacity Easy mounting onto35 mm din rail The certificate:ccc, ce, cb, s, iram. 43*23.5*17cm 13/12kg 120pcs/ctn
Wati-hour meter, capacitor series, reactive field compenstor, reactive power auto compensation controller, leakage circuit protectment series, cj19 switch-over capacitor contactor, dz47 miniacture circuit breaker with hign breaking capacity plastic moulded cased circuit breaker, dz series leakage circuit breaker, cj series ac contactor, knife switch series, module sockets.
- USED ELCB - Made in Korea brands (Mixed : LS, Hyundai, Daco....) -15 ~ 30A - 8 ~10pcs/kg (FOB 4.9usd /kg)
BDZ52 Explosion Proof Circuit Breaker Applications: Explosive gas atmosphere Zone 1 and Zone 2 Combustible dust areas Zone 21 and Zone 22 Explosive gas mixture classification IIA, IIB, IIC Explosive gas ignition temperature group T1-T6(T4) Technician specifications Meet a criterion:GB3836.1, GB3836.2, GB3836.3, GB12476.1, GB12476.5,IEC60079-0, IEC60079-1, IEC60079-7, IEC61241-0,IEC61241-1,EN60079-0,EN60079-1, EN61241-0, EN61241-1-1 Explosion-proof mark: Exd II BT4 Gbã?�Exd II CT4 Gbã?�Exde II BT4 Gbã?�Exde II CT4 Gbã?�ExtD A21 IP66 T130? Rated voltage:AC220V/380V Rated current:MCB¤63A 63A
PLHT 100 amp mechanical electrical circuit breakers is nice in appearance,reasonable in structure,sound in feature and high in breaking capacity.Installed with standard din rail,it is convenient and easy in usage.It can be used as infrequent on-and-off operation and changeover. Complying with standard GB10963 and IEC/EN60898.
A6 1P circuit breaker switch belongs to the advanced level of the nineties in the world. They have protective functions as shortage and overloading,and are used in lighting distribution system in industry,commerce and dwelling,and protect fractional electric motors.And they also have many merits of high protective grade(up to IP20),high breaking capacity,good reliability of sensitive action,convenient multi-pole assorting,long using life etc.They are mainly adapted to the circuit of AC50Hz, 230V in single pole,400V in double,three on four poles for protecting overload and shortage.Meanwhile,they are also used in turning on or off the electric apparatus and lighting circuit under the normal condition.
Mini circuit breaker (mcb), mcb accessories (of, sd, mx, & mns), residual current devices / earth leakage circuit breaker (rcd/elcb), moulded case circuit breaker (mccb), ac contactor, modular contactors, thermal relay, isolating switch, waterproof swtich, rotary switch, industrial plugs & sockets, distribution box, fuses & fuses carries, cable ties & cable clips, terminal blocks, Din rail, busbar, LED.
Factory price industrial 56CB4N ip66 electronic circuit breaker plug covers electrical Power Distribution Box Model Number: 56CB4N Breaking Capacity: Rated Voltage: 240V Rated Current: 0.03A BCD Curve: C Type: Other Rated Frequency (Hz): 50HZ Number of Pole: 2 Protection: Other
2-wire & 4-wire circuit breakers Description It is an electronic type circuit breaker. The PG circuit breaker range, from 5 to 60 A, 2P (1 Ph + N) or 4P (3 Ph + N), with or without earth leakage protection (300 mA - 500 mA or 650 mA), offers the right product to suit each type of installation. It complies with NFC 61-450; IEC60947-2 French standard. DISJONCTEURS DIFFERENTIELS BIPOLAIRES 5/15A 1 Tension de fonctionnement 220V 2 Calibrage (REGLABLE) 5A, 10A, ou 15A 3 Fr�©quence 50Hz 4 Nombre de p�´les 2 5 Nombre de p�´les prot�©g�©s 1 6 500mA 7 Chute de tension
CHARACTERISTICS 1. The vacuum arc extinguishing chamber uses longitudinal magnetic field arc extinguishing technology, which has the characteristics of long electric life and high reliability. 2. The imported silicone rubber/epoxy resin for outdoor use and the present APG vacuum injection technology are adopted. 3. Anti-ultraviolet, moistureproof, anti-corrosion, with the advantages of preventing surface discharge, good hydrophobicity and high mechanical strength. 4. Using simple and reliable spring operating mechanism, it has the advantages of small size and light weight. 5. high voltage vacuum circuit breaker can be equipped with isolation switch and three-phase linkage. It has visible breaks when the isolation switch is switched off. It also has anti-mistake interlock between the isolation switch and the circuit breaker body. It can be equipped with arrester strut insulators. Operational sequence When operating the disconnector, the first step is to confirm that the circuit breaker should be in the open state. Use the insulated tie rod hook to fasten the closing pull ring or the opening pull ring of the operating handle of the isolation closure, pull down slightly, drive the spindle to rotate, open or close the isolation switch. When the spindle rotates the dead point position of the compression spring, a certain tension is maintained so that the blade can be reliably closed or opened to a safe isolation position.
WSD-ZW32-24D Outdoor AC high voltage vacuum circuit breaker (hereinafter referred to as circuit breaker) is a rated voltage of 24 KV, 50 HZ three-phase AC outdoor distribution equipment.The utility model has the advantages of stable and reliable interruption performance, no danger of combustion and explosion, maintenance-free, small size, light weight and long service life.It is mainly used for breaking and closing the load current, overload current and short circuit current in power system.It is suitable for protection and control in power distribution systems of substations and industrial and mining enterprises, and more suitable for rural power grids and frequently operated places. This product meets GB1984-2003 "High Voltage AC Circuit Breakers" and DL/T402-2007 "Technical Conditions for Order of High Voltage AC Circuit Breakers" and DL/T403-2000 "Technical Conditions for Order of 12 kV~40.5 kV High Voltage Vacuum Circuit Breakers" and other technical standards.
MCB has the characteristics of advanced structure, reliable performance, high breaking capacity and beautiful appearance. It is mainly used for AC 50HZ or 60HZ, rated voltage 400V or below and rated working current 63A or below. It is used for overload and short-circuit protection of lighting, distribution lines, equipment in office buildings, residential buildings and etc. It can also be used for infrequent on-off operations and conversion of lines.
Mini hydraulics electromagnetic AC DC Toggle Type Circuit Breaker for Equipment Electrical Panel Control trip free 1-50A
Our featured products automatic transfer switch, circuit breaker, contactor, pilot light,relay, SPD, etc. with solid quality and considerable price and could equip them with enclosure. Circuit Breaker DZ47 is an automatically operated electrical switch designed to protect an electrical circuit from damage caused by overload or short circuit. Its basic function is to detect a fault condition and, by interrupting continuity, to immediately discontinue electrical flow. When a current is interrupted, the arc must be contained, cooled, and extinguished in a controlled way. So that the gap between the contacts can again withstand the voltage in the circuit. Electric ratings:Â a. AC: up to 63A, AC230/400V, AC50/60Hz; b. DC: up to 63A, DC110V/1P, DC125V/2P; Application: for protection of circuits from over-load and short-circuit; and for infrequent making and breaking of circuits under normal operation conditions, as well; Standard: IEC/EN 60898.
Miniature Circuit Breaker Automatic Assembly and inspecting line MCB Automatic Assembly and inspecting line Keyword: Miniature Circuit Breaker Automatic Assembly, Miniature Circuit Breaker, Automatic Assembly line, Assembly Machine, Assembly Production Line Product Introduction Basic operation process: ï?¼Loading by AGV robots, printing QR codes based on the product work order issued by the SAP system, and then separating the upper and lower shells. ï?¼Bottom coating of the upper shell: The installation of three components is completed through ten processes, and after each assembly is completed, there is a corresponding installation accuracy testing process to ensure that the assembly is completely qualified. ï?¼Installation of lower shell components, upper and lower shell assembly: A total of 25 processes are used to install 12 components. After each part is assembled, guide pins are used to ensure the upper and lower assembly. After the installation of internal components is completed, the product's on/off function is tested. After passing the test, rivets are installed, pressed again, and the screws are removed. All installations are checked, and after passing the test, they are transferred to the inspection station. ï?¼Unipolar products undergo instantaneous detection, delay detection, cooling tower and other unit inspections, and are then labeled with QR codes and covers before being transferred to the next workstation. ï?¼Multi pole products require 9 steps of multi pole assembly, and after assembly, a second delay is performed to verify the stability and reliability of the product ï?¼Finally, it is transferred to the automatic packaging unit through pressure resistance testing, transfer printing, laser labeling, and buckle installation. The specific parameters: (1) Equipment input voltage: 220V �± 10%, 50Hz; (2) The equipment has functions such as automatic shell loading, lid opening, assembly of arc extinguishing plates, magnetic guide plates, handle springs, base springs, positioning pins, handles, jump buckles, locks, coil components, iron core components, wiring columns, adjustment screws, arc extinguishing covers, CCD recognition, lid closing, identification of qualified and unqualified products, assembly of cutting processes, online detection, real-time monitoring, component life monitoring, data storage, MES system and ERP system networking, parameter arbitrary formula, smart energy analysis and energy-saving management system, intelligent equipment service big data cloud platform, etc. (3) Theoretical production effeciency: 2 seconds per unit; Daily production of approximately 14400 pieces/8 hours; (4) This device has the function of power-off to save data for 30 days, making it easy to manage production data; (5) This device adopts touch screen operation, has a computer communication interface, and printing function
NW12N13PEF2.0E Air Circuit Breaker Masterpact NW12N1: 1250 A, 3 poles, fixed trip unit and Motorized
ZW32-24 type outdoor pole-mounted HV vacuum CB (hereinafter referred to as CB) is rated voltage24kV, 50Hz three-phase AC outdoor power distribution equipment used for power distribution network to break and close load current, over-load current and short-circuit current in electric systems. It is used in substation and industrial & mining enterprise power distribution system for protection and control, better fits countryside power grid and frequent operation places, especially for the retrofit of urban power network and countryside power network. Characteristic: The CB applies three-phase pole-type structure. It has characteristics of stable closing/breaking property, no fire or explosion danger, maintenance-free, small dimension, small weight, long service life, etc. The CB is hermetical sealed, and is moisture-resistant, anti-condensation. It is especially suitable for application at severe cold and damp areas. Three-phase pillar and current transformer apply imported outdoor epoxy resin solid insulation materials. It is high/low temperature resistant, UV-resistant and anti-ageing. The operating mechanism is miniature spring operating mechanism with low breaking/closing energy consumption. The driving of it applies straight transmission with little components and high reliability. The operating mechanism is enclosed in a cabinet, and that makes it rust-resistant and more reliable.